the or test review Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Question | Answer |
what is not a factor for a disinfected | size of object |
what type of spore is used to test the EO/dry heat sterilizer | bacillus subtilis |
what type of spore is used to test steam under pressure/autoclaving | bacillus stearothermophilus |
when are gloves/gowns removed when leaving the OR | before |
which are cleaned weekly | cabinet shelves |
agent that kills all micoorganisms except spore-bearing ones | disinfectant |
method of sterilization w/cobalt 60 | ionizing radiation |
to change the vital functions,forces & activities of an organ | denaturation |
agent that kill bacteria | bacteriocidal |
agent that inhibts the growth of micoorganisms on animate surfaces | antiseptic |
all affect sterilization process except | type of sterilizing agent |
uses agitated water w/detergent to loosen soil, then steam displaces the water and items are sterilized at 132 c or 270 f | washer-sterilizer |
is a smaller version sterililzer, can reach higher temps w/reduced exposure time | high speed (flash) gravity sterilizer |
unwrapped metal instruments are sterilized at | 132 c (270 f), 3 minutes minimum, at 27 PSI |
unwrapped metal instruments combined w/porus materials are sterilized at | 132 c (270 f), 10 minutes minimum, at 27 PSI |
wrapped instruments,packs,bulk loads are sterilized at | 121 c (250 f), 30 minutes minimum, at 15 PDS |
a steam sterilizer is how hot | 250 f |
EO sterilization is not dependent on | gravity |
what type of sterilization is perferred for air powered instruments | EO |
what is not used as an antiseptic | glutaraldehyde |
how long does activated glutaraldehyde require in total immersion for disinfection | 10 minutes |
instruments must be rinsed how many times w/sterile distilled water | at least 2 times |
what is not a method of the sterilization process | physical |
which is a method of the sterilization process | chemical |
used primarily for oils,petroleum & bulk powders | hot air/dry heat |
when preparing items for sterilization how should the lock boxes be positioned | opened |
when preparing items for sterilization all detachable parts s/be | disassembled |
what is not a recommended characterisitic for packaging material | have a good memory |
most common method of wrapping articles for sterilization | envelope/peel pack |
items s/be sequentially wrapped w/which | 2 double thickness |
which film of 1-3mm thickness is the only plastic acceptable for steam sterilization | polypropylene |
which is not acceptable for gas sterilization | nylon |
wrapped items s/remain untouched for how long | 30-60 min |
pack size s/be no larger than | 12x12x20 |
pack size s/be not heavier than | 12 lbs |
the outside of a steam sterilizer s/be cleaned | daily |
the bowie dick type test is used on which type of sterilizer | pre-vacuum |
item is gas sterilized, it is porus and must be aerated to | avoid toxic residue |
what is not used in the OR to clean | glutaraldehyde |
anesthesia equipment is changed when | after each pt |
how often s/steam sterlizers be cleaned | weekly |
what role does humidity play in the EO | hydrate spores |
what is not a form of sterilization | boiling water |
EO kills microorganism by | denaturation & chemical interference |
all are manual method except | instruments are placed into the washer-sterilizer |
when s/the OR table be wiped down | after each pt |