3E051 Set D book 1

Quiz yourself by thinking what should be in each of the black spaces below before clicking on it to display the answer.
        Help!  

Question
Answer
The preferred Air Force base distribution system is   3-phase, 4-wire  
🗑
A substation with one incoming transmission circuit and three outgoing distribution cirdcuits has (at least) how many lighting arresters?   12  
🗑
Which item supplies control voltage to operate circuit breakers?   batteries  
🗑
What is the configuration of an induction-voltage regulator's primary and secondary windings?   the primary is in shunt and the secondary is in series  
🗑
In regards tko the circuit, how are a step-voltage regulator's primary and secondary windings configured?   primary is in parallel and secondary is in series  
🗑
When can the secondary of a current transformer be opened?   when the primary is deenergized  
🗑
Which is not a major funtion of an oil circuit breaker?   to stabilize current flow during an overload situation  
🗑
What oil circuit breaker components supply amperage to the protective relays?   current transformer  
🗑
What percent of electrical system faults are temporary?   95 percent  
🗑
Of these devices, which does not interrupt a fault current?   sectionalizer  
🗑
Air-break switches can be used to break a circuit "under load" if they have   arc horns  
🗑
Why is the arc extinguished so quickly in a vacuum recloser?   there is very little oxygen to burn  
🗑
The insulating quality of sulfur hexafluoride (SF6), at 0 PSI, is how much greater than dry air?   2.5 times  
🗑
A high voltage switch is connected to the distribution system that it is protecting in   loop  
🗑
What is usually installed with an oil circuit breaker to allow for equipment maintenance, letting you keep the circuit in operation?   knife blades and a normally open air-break switch  
🗑
Oil circuit breaker contacts that are discolored by excessive heat should be   replaced  
🗑
Dielectric check the oil in oil circuit breakers   every 6 months  
🗑
Which of these acids mixed with water is an effective solution for cleaning insulators and bushings?   muriatic  
🗑
What do you use to clean the arc interrupters of an air-break switch?   cloth or light sanding  
🗑
Clean a modern air switch that has been closed for a long period of lim by   opening and closing the switch several times  
🗑
Battery bank maintenance is normally done   monthly  
🗑
What do we use to test a battery cell for its specific gravity?   hydrometer syringe  
🗑
What must you do if you add water to a battery in freezing temperatures?   charge the battery  
🗑
The dielectric test voltage for a relay that is rated at 600 volts is   2200 volts  
🗑
After a wiring change to a control device, check substation circuits for   proper operations  
🗑
Switchboard graphic instruments and revenue watt-hour meters must be calibrated every   4 years  
🗑
What device is essentially a voltage regulator and requires similair servicing?   distribution transformer  
🗑
What is the first step in isolating a voltage regulator?   place regulator in the neutral or zero position  
🗑
For each degree below 77 F, battery capacity is reduced by what percent?   .8  
🗑
What must you do after repair work on a relay?   make a complete performace test  
🗑
Which meter do you use in a transformer continuity check?   megger  
🗑
If a continuity check between the primary and secondary transformer windings shows a zero reading, the transformer is probably   shorted  
🗑
What publication outlines how to perform a flash hazard analysis to determine personal protective equipiment requirement?   NFPA 70 E  
🗑
Hard hats must meet ANSI 289.1 Class E requirements 20,000 VAC test for how many minutes?   3  
🗑
Proper wear of arcflash resistant cloths includes?   coveralls worn with sleeves rolled down  
🗑
How often should the supervisor inspect body belts and safety straps?   every 6 months  
🗑
Which of these is used for a bending test on a body belt or safety strap?   3/4 inch mandrel  
🗑
Which of these is not a way to tell whether gaffs are sharpened properly?   slope test  
🗑
Which part of the gaff do you sharpen?   flat inner side  
🗑
What is the required rhythm method when climbing a utility pole?   left arm raises as left foot rises  
🗑
What is the OSHA standard for retraining of climbing tasks performed less than once per year?   annually  
🗑
Leather protectors or gauntlets should be   2 to 5 inches shorter than the rubber gloves  
🗑
For full protection up to the shoulder, rubber sleeves are   worn tucked into rubber gloves  
🗑
Which of these combinations are likely to use inside rubber gloves?   cotton gloves and dusting powder  
🗑
How often are rubber gloves given an electrical test?   every 6 months  
🗑
The supervisor must inspect rubber blankets visually every   6 months  
🗑
How must rubber blankets be stored?   flat or rolled in blanket canister  
🗑
Which of the following manufacturer's certification test is acceptable for hotsticks?   100,000 VAC per foot for 5 minutes on fiberglass and epoxy sticks  
🗑
How often are hot-line tools tested electrically?   every 6 months  
🗑
Test hot sticks electrically with a   DC hi-pot test set  
🗑
How many high-voltage test are made on a hot stick before it can pass?   4 one-foot segment tests and one overall test  
🗑
At the job site, the aerial lift device should be positioned so the work area is always   within reach of the boom  
🗑
While raising the bucket, the operator should always face in the direction   in which the bucket is moving  
🗑
Materials or tools can only be passed from a worker on the ground to a worker on the aerial lift vehicle when   both workers are wearing rubber gloves  
🗑
All in-use aerial devices must recieve a daily   pretest inspection and periodic verification test  
🗑
The moisture test setup is the same as the   upper boom insulation test  
🗑
Who is responsible for daily inspections and overseeing other testing on the aerial lift truck?   principal operator  
🗑
The line truck winch is operated   through the power takeoff  
🗑
When you must work on a slope, position the truck so the work is   on the high side of the truck  
🗑
How is the rope put on the capstan?   wind it clockwise, wiuth the load end next to the truck  
🗑
Holding up a closed fist indicates what?   stop all action  
🗑
The key to using hand signal is what?   All signals are approved by the Air Force  
🗑
Which of these is the Operator's Inspection Guide and Trouble Report on which you write up line truck inspection discrepancies?   AF form 1806  
🗑
Which of the following does the motor pool handle?   tire change  
🗑
While you are operating the line maintenance truck, which gauge is the most important to watch?   tachometer  
🗑
In addition to engineers or the planning Section, who assists in making a "staking sheet" of the area over whick the line is to pass?   a survey crew  
🗑
Use AF Forsm 103, Base CE work clearance request for   digging permits  
🗑
For poles that are subject to more strain than normal, how many inches deeper do we set them?   6  
🗑
What method do we use to remove dirt from a power auger?   by spinning it off  
🗑
What is the minimum number of workers needed for pole handleing?   2  
🗑
What tool do workers use to position poles on the ground?   cant hook  
🗑
Sort a large number of poles to be stored by   length  
🗑
What method do we usually use to load poles on a trailer?   boom method  
🗑
In determining the class of a pole, how far up from the pole's butt do we measure it's circumference?   6 foot  
🗑
What type of roof do we find on untreated wood poles?   slant  
🗑
What must you do before you cut the roof on a wood pole?   find the pole's face side and back side  
🗑
Where do we make the gain on a wood pole?   face side of the pole  
🗑
In using the line truck and winch to set a pole, attach the winch line before you raise the pole slightly   above the midpoint of the pole  
🗑
If a pole must be set in an energized line, what two additional articles of equipment must be used?   rubber gloves and a pole gaurd  
🗑
Which of these is the best situation for backfilling a pole hole?   one shoveler and 3 tampers  
🗑
What is the maximum amount of pole line angle you can have without needing a guy wire?   5 degrees  
🗑
What type of anchor do we use for hard or compact soil?   expanding anchor  
🗑
What type of guy do we normally use at a curve in the line?   side guy  
🗑
Which of these combinations fo you use to draw up a guy wire and hold it in place for attachment to the anchor rod?   chain hoist and 2 strand grips  
🗑
What are the considered factors that establish the three loading areas for conductors in the US?   longitudinal traverse and vertical loading  
🗑
What insulator material is more resistant to vandalism?   fiberglass  
🗑
What knots does the person on the ground use to raise a crossarm?   half hitch ad a clove hitch  
🗑
Use armor rod on   aluminum conductors  
🗑
You are building a new pole line; which onductor does the person on the ground send up first is you are on the second pole   the inside conductor  
🗑
With what splice do you have to choose the correct size die?   compression  
🗑
What do you do to prevent a hot-line clamp from burning a main conductor?   use a stirrup  
🗑
what information do you need to find the proper amount of sag?   span length, conductor type, temperature and loading district  
🗑
What type of insulator is used at the dead end for a primary conductor?   susspension insulator  
🗑
pad mount transformers is the perferred mounting method for what transformer size?   225 kVA  
🗑
Which method do we most likely use to install, single-phase transformer?   block and tackle  
🗑
Where do you connect the top and bottom connection points of a transformer's lighting arrestor?   top to primary wire, bottom to ground wire  
🗑
What causes a low power factor on a distribution line?   large induction load in the circuit  
🗑
What can we install to raise the power factor in a distribution circuit?   transformers  
🗑
What device do we use across a capacitor's terminals to gradually discharge the capacitor?   resistor  
🗑
For a below-ground check of a pole, to what depth do you dig the trench?   8 to 18 inches  
🗑
At what location on a crossarm does decay usually start?   pin holes  
🗑
What condition can cause a crossarm to twist?   unbalanced strain or insufficient guying  
🗑
When a span shows too much sag while adjacent spans appear normal,   the conductor has streched from being hit by a falling object  
🗑
We must make voltage and current readings on capacitor installation at least   4 times per year  
🗑
Where would you put the tree pruner to add a thirs section?   lean it against a tree limb  
🗑
To remove a limb, where do you make the last cut?   flush with the trunk or parent limb  
🗑
Which device can you use to detect a problem before service is interrupted?   infrared detector  
🗑
What must the electrician do before working on deenergized lines?   test and ground the lines  
🗑
How is the cable used for ground sets constructed?   600-volts insulated rubber or synthetic-covered flexible copper  
🗑
The first connection you make in applying a ground set is the   ground  
🗑
What a break occurs in an energized line, how is the line at the break affected?   the center disappears, leaving soft wire on either side  
🗑
When you replace an arrestor that has been damaged by storke of lighting, what do you also check for damaged?   ground wire  
🗑
What must you do before working on energized lines?   inspect hot line tools and equipment for proper operation  
🗑
What two connector types do we use when splicing energized conductors?   compression and automatic.  
🗑
On energized conductors, we keep the tie wires short when removing them from the insulator because this   prevents the tie wire from contacting other phases  
🗑
What tie stick head do we normally used to untie tie wires?   rotary blade  
🗑
What do we use to raise the auxiliary crossarm assembly once we untie the tie wires?   a snatch block  
🗑
How many line hoses are needed for a pole change when the pole has a single crossarm supporting three phase conductors?   8  
🗑
When replacing a pole, how many feet above the pole do you raise the auxililary arm?   3 to 4 feet  
🗑
The high voltage audible indicator makes an audible sound when placed   in an electrostatic field  
🗑
The act of tying a tagline to each outside conductor with a bowline knot and pulling the conductors out of the work area we call   tagging out  
🗑
Where do you place the crossarm prior to securing it to the pole with a throughbolt?   lineman's safety strap  
🗑
The service meter normally measures   kW- hours  
🗑
What is the formula to find the amount of watt-hours used?   new reading minus the previous reading  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: melissafish
Popular Military sets