Fire protection

Quiz yourself by thinking what should be in each of the black spaces below before clicking on it to display the answer.
        Help!  

Question
Answer
For a fire to occur, there must be   Fuel,oxygen, and heat  
🗑
A fire with solid combustables is also knows as   Class a fire  
🗑
A fire formed from fuel is also known as   Class b fire  
🗑
A fire which there are electrical circuits is   Class c  
🗑
A fire formed from metal is   Class d fire  
🗑
A wheel well or wing is what kind of fire   Class d  
🗑
The two general categories of fire detection systems are   Continuous loop & spot detector  
🗑
The thermal switch fire detection system Is a   Spot type system  
🗑
Thermal switch fire detection systems respond to a   Pre -set temperature  
🗑
Thermal switch fire detectors are connected in ____ with each other   Parallel  
🗑
A significant advantage of double loop detection circuits is that it can withstand a _____ such as a ____ or ____ circuit without causing false warnings   Fault , short , open  
🗑
Thermocouple fire detection systems may also be known as the ______   Spot type  
🗑
Carbon dioxide _____ effective on class B & C fires   Is  
🗑
Halogenated hydrocarbons are identified through a system of _____ numbers   Five digit  
🗑
The typical inspection items for portable fire extinguishers are   Weighing , checking gauges  
🗑
HRD extinguishing systems are discharged by an electrically ignited discharge cartridge called a   Squib  
🗑
If an installed fire extinguisher system has been discharged by normal operation the _____ blowout desk will be ruptured   Yellow  
🗑
Almost all type of fire extinguisher containers require ______ to determine the amount of extinguishing agent   Weighing  
🗑
Fire extinguisher containers must be hydrostatically tested every ____ years   Five  
🗑
If a discharge cartridge is removed from a discharge valve it ________ be used in another discharge valve assembly   May not  
🗑
Thermocouple fire detection systems respond to a   Rise of temperature  
🗑
In the thermocouple systems, one thermocouple called the ________ thermocouple is placed in a location that is relatively well protected from the initial flame   Reference  
🗑
The two relays in a thermal couple fire detection system are   Sensitive relay, slave relay  
🗑
More complete coverage of a fire hazard area then as provided by a spot detector system may be obtained using a ________________ fire detection system   Continuous loop  
🗑
The_____Continuous loop system uses two wires inside the Inconel tube   Kiddle  
🗑
A ________fire detection system may also function as an overheat indicator   Continuous loop  
🗑
The two types of sensor responder systems that may be found in use are the   Lynd burg system , system donner  
🗑
What two gases are toxic to humans, may indicate a fire condition and may provide the earliest warning of a dangerous situation   Nitrous- oxide, carbon dioxide  
🗑
________ type smoke detectors is a small amount of radioactive material to ionize some of the oxygen and nitrogen drove into the unit   Ionization  
🗑
Three types of smoke detection units which may be found on aircraft are   Light refraction, ionization, flame  
🗑
Cabin upholstery materials installed in the current standard category airplane must   Be at least flame resistant  
🗑
In what area of an aircraft would you find a carbon monoxide detector?   Cockpit and/ or cabin  
🗑
What occurs when a visual smoke detector is activated   A lamp within the indicator illuminates automatically  
🗑
The types of fire extinguisher agents for aircraft interior fires are   Water, carbon dioxide, dry chemical, halogenated hydrocarbons  
🗑
When air samples contain carbon monoxide, portable carbon monoxide detectors containing yellow silica gel will turn what color   Green  
🗑
Smoke detection instruments are classified by their method of   Detection  
🗑
Smoke detectors which use a measurement of light transmissibility in the air are called   Photo electric devices  
🗑
A contaminated carbon monoxide portable test unit would be returned to service by   Installing a new indicating element  
🗑
Which fire detection system measures temperature rise   Thermocouple  
🗑
A carbon dioxide handheld fire extinguisher may be used on an electrical fire if the   Horn is non-metallic  
🗑
The proper fire extinguishing agent to use on aircraft brake fire is   Dry powder chemical  
🗑
Smoke in the cargo and/or baggage compartment of an aircraft is commonly detected by what instrument   Photo electric cell  
🗑
Light refraction smoke detectors   Sense light reflected from smoke particles passing through a chamber  
🗑
Why does the fen wall fire detection system use spot detectors wired parallel between two separate circuits   A short may exist in either circuit without causing a false fire warning  
🗑
A fire extinguisher container can be checked to determine its charge by   Weight  
🗑
What is the color code for fire extinguisher lines   Brown  
🗑
The most common cause Of a false fire warnings and continuous loop fire detection system is   Dents , kinks, or crushed sensor sections  
🗑
A thermocouple and a fire detection system causes the warning system to operate because   It generates a small current when heated  
🗑
A thermocouple fire warning system is activated by a   Rate of temperature rise  
🗑
When used in fire detection systems having a single indicator light, thermal switches are wired in   Parallel with each other and in series with the light  
🗑
Built in aircraft fire extinguishing systems are ordinarily charged with   Halogenated hydrocarbons, and nitrogen  
🗑
What method is used to detect a thermal discharge of a belt and fire extinguisher system   A rupture of the red plastic disc in the thermal discharge line  
🗑
The thermal switches on a bimetallic thermal switch type fire detection system are heat sensitive units that complete circuits at a certain temperature. they are connected in   Parallel with each other, but in series with the indicator lights  
🗑
On a periodic check of fire extinguisher containers, the pressure was not between minimum and maximum on it. what procedure should be followed?   Replace the extinguisher container  
🗑
And some fire extinguishing systems, evidence that the system has been intentionally discharged as indicated by the absence of a   Yellow disk on the side of the fuselage  
🗑
If a fire extinguisher cartridge is removed from a discharge valve for any reason it   Is recommended that the cartridge be used only on the original discharge valve assembly  
🗑
Which fire extinguisher agent is considered to be the least toxic   Carbon dioxide  
🗑
Maintenance of fire detection systems include the   Replacement of damaged sensing elements  
🗑
A squib, as used in fire protection system is a   Device for causing the fire extinguishing agent to be released  
🗑
Halon 1301   Flooding agent  
🗑
Halon 1211   Streaming agent  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: Bnich
Popular Standardized Tests sets