| For a fire to occur, there must be | Fuel,oxygen, and heat
🗑
|
||||
| A fire with solid combustables is also knows as | Class a fire
🗑
|
||||
| A fire formed from fuel is also known as | Class b fire
🗑
|
||||
| A fire which there are electrical circuits is | Class c
🗑
|
||||
| A fire formed from metal is | Class d fire
🗑
|
||||
| A wheel well or wing is what kind of fire | Class d
🗑
|
||||
| The two general categories of fire detection systems are | Continuous loop & spot detector
🗑
|
||||
| The thermal switch fire detection system Is a | Spot type system
🗑
|
||||
| Thermal switch fire detection systems respond to a | Pre -set temperature
🗑
|
||||
| Thermal switch fire detectors are connected in ____ with each other | Parallel
🗑
|
||||
| A significant advantage of double loop detection circuits is that it can withstand a _____ such as a ____ or ____ circuit without causing false warnings | Fault , short , open
🗑
|
||||
| Thermocouple fire detection systems may also be known as the ______ | Spot type
🗑
|
||||
| Carbon dioxide _____ effective on class B & C fires | Is
🗑
|
||||
| Halogenated hydrocarbons are identified through a system of _____ numbers | Five digit
🗑
|
||||
| The typical inspection items for portable fire extinguishers are | Weighing , checking gauges
🗑
|
||||
| HRD extinguishing systems are discharged by an electrically ignited discharge cartridge called a | Squib
🗑
|
||||
| If an installed fire extinguisher system has been discharged by normal operation the _____ blowout desk will be ruptured | Yellow
🗑
|
||||
| Almost all type of fire extinguisher containers require ______ to determine the amount of extinguishing agent | Weighing
🗑
|
||||
| Fire extinguisher containers must be hydrostatically tested every ____ years | Five
🗑
|
||||
| If a discharge cartridge is removed from a discharge valve it ________ be used in another discharge valve assembly | May not
🗑
|
||||
| Thermocouple fire detection systems respond to a | Rise of temperature
🗑
|
||||
| In the thermocouple systems, one thermocouple called the ________ thermocouple is placed in a location that is relatively well protected from the initial flame | Reference
🗑
|
||||
| The two relays in a thermal couple fire detection system are | Sensitive relay, slave relay
🗑
|
||||
| More complete coverage of a fire hazard area then as provided by a spot detector system may be obtained using a ________________ fire detection system | Continuous loop
🗑
|
||||
| The_____Continuous loop system uses two wires inside the Inconel tube | Kiddle
🗑
|
||||
| A ________fire detection system may also function as an overheat indicator | Continuous loop
🗑
|
||||
| The two types of sensor responder systems that may be found in use are the | Lynd burg system , system donner
🗑
|
||||
| What two gases are toxic to humans, may indicate a fire condition and may provide the earliest warning of a dangerous situation | Nitrous- oxide, carbon dioxide
🗑
|
||||
| ________ type smoke detectors is a small amount of radioactive material to ionize some of the oxygen and nitrogen drove into the unit | Ionization
🗑
|
||||
| Three types of smoke detection units which may be found on aircraft are | Light refraction, ionization, flame
🗑
|
||||
| Cabin upholstery materials installed in the current standard category airplane must | Be at least flame resistant
🗑
|
||||
| In what area of an aircraft would you find a carbon monoxide detector? | Cockpit and/ or cabin
🗑
|
||||
| What occurs when a visual smoke detector is activated | A lamp within the indicator illuminates automatically
🗑
|
||||
| The types of fire extinguisher agents for aircraft interior fires are | Water, carbon dioxide, dry chemical, halogenated hydrocarbons
🗑
|
||||
| When air samples contain carbon monoxide, portable carbon monoxide detectors containing yellow silica gel will turn what color | Green
🗑
|
||||
| Smoke detection instruments are classified by their method of | Detection
🗑
|
||||
| Smoke detectors which use a measurement of light transmissibility in the air are called | Photo electric devices
🗑
|
||||
| A contaminated carbon monoxide portable test unit would be returned to service by | Installing a new indicating element
🗑
|
||||
| Which fire detection system measures temperature rise | Thermocouple
🗑
|
||||
| A carbon dioxide handheld fire extinguisher may be used on an electrical fire if the | Horn is non-metallic
🗑
|
||||
| The proper fire extinguishing agent to use on aircraft brake fire is | Dry powder chemical
🗑
|
||||
| Smoke in the cargo and/or baggage compartment of an aircraft is commonly detected by what instrument | Photo electric cell
🗑
|
||||
| Light refraction smoke detectors | Sense light reflected from smoke particles passing through a chamber
🗑
|
||||
| Why does the fen wall fire detection system use spot detectors wired parallel between two separate circuits | A short may exist in either circuit without causing a false fire warning
🗑
|
||||
| A fire extinguisher container can be checked to determine its charge by | Weight
🗑
|
||||
| What is the color code for fire extinguisher lines | Brown
🗑
|
||||
| The most common cause Of a false fire warnings and continuous loop fire detection system is | Dents , kinks, or crushed sensor sections
🗑
|
||||
| A thermocouple and a fire detection system causes the warning system to operate because | It generates a small current when heated
🗑
|
||||
| A thermocouple fire warning system is activated by a | Rate of temperature rise
🗑
|
||||
| When used in fire detection systems having a single indicator light, thermal switches are wired in | Parallel with each other and in series with the light
🗑
|
||||
| Built in aircraft fire extinguishing systems are ordinarily charged with | Halogenated hydrocarbons, and nitrogen
🗑
|
||||
| What method is used to detect a thermal discharge of a belt and fire extinguisher system | A rupture of the red plastic disc in the thermal discharge line
🗑
|
||||
| The thermal switches on a bimetallic thermal switch type fire detection system are heat sensitive units that complete circuits at a certain temperature. they are connected in | Parallel with each other, but in series with the indicator lights
🗑
|
||||
| On a periodic check of fire extinguisher containers, the pressure was not between minimum and maximum on it. what procedure should be followed? | Replace the extinguisher container
🗑
|
||||
| And some fire extinguishing systems, evidence that the system has been intentionally discharged as indicated by the absence of a | Yellow disk on the side of the fuselage
🗑
|
||||
| If a fire extinguisher cartridge is removed from a discharge valve for any reason it | Is recommended that the cartridge be used only on the original discharge valve assembly
🗑
|
||||
| Which fire extinguisher agent is considered to be the least toxic | Carbon dioxide
🗑
|
||||
| Maintenance of fire detection systems include the | Replacement of damaged sensing elements
🗑
|
||||
| A squib, as used in fire protection system is a | Device for causing the fire extinguishing agent to be released
🗑
|
||||
| Halon 1301 | Flooding agent
🗑
|
||||
| Halon 1211 | Streaming agent
🗑
|
Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Created by:
Bnich
Popular Standardized Tests sets