Question
Answer
A company that provides connection to a part of the Internet, public network, or other services such as application programming interfaces is called:   Service provider  
🗑
the leading trade association representing the global information and communications technology (ICT) industry through standards development, policy initiatives, business opportunities, market intelligence and networking events   TIA - Telecommunications Industry Association  
🗑
The point at which the public utility service provider terminates network responsibility and the user assumes responsibility for maintenance of the network is called the   Demarkation Point  
🗑
In the United States, who regulates service providers?   Good question... no answer  
🗑
Where was BICSI first incorporated?   Kentucky  
🗑
TIA started as a committee within what organization?   EIA (Electronics Industry Alliance)  
🗑
What did the Telecommunications Act of 1996 do?   Deregulated the Telecommunications Industry  
🗑
In what year did divestiture of AT&T occur?   1984  
🗑
What BICSI program initiated the registration of communications distribution designers in 1984?   Registered Communications Distribution Designer (RCDD)  
🗑
What does BICSI stand for?   Building Industry Consulting Services International  
🗑
What year was BICSI incorporated?   1977  
🗑
What two companies founded the BICS organizations?   AT&T and Bell Canada  
🗑
An ITS Installer should be able to lift a maximum of________ Pounds?   48.5  
🗑
How many years experience are required to become a Level 1 Installer?   0  
🗑
How many years experience are required to become a Level 2 Installer?   2  
🗑
How many years experience are required to become a Technician?   5  
🗑
What are the steps required to renew an ITS Installer 2 and a Technician registration?   Complete OJT and submit to BICSI Complete 12 CECs Be active in the industry Submit an application and renewal fee to BICSI  
🗑
How many years are allowed to complete the OJT?   2  
🗑
How many times can the written test be taken in one year?   3  
🗑
Who must sign off on OJT tasks?   Your Supervisor  
🗑
What are the three levels of instruction for the cabling installation program?   Level 1, Level 2, Technician  
🗑
ITS Technician Level Installers must be able to tolerate a variety of body positions while working, such as; standing, bending forward frequently, stooping, kneeling, and crouching.   True  
🗑
It is not necessary for ITS Technician Level Installers to be able to recognize colors.   False  
🗑
Must an ITS Technician Level Installers be able to perform geometrical calculations, understand and interpret graphs, and calculate fractions and percents?   True  
🗑
ITS Technician Level Installers must be able to perform conversions of metric and empirical numbers.   True  
🗑
What is installing cable within a structured premises cabling installation that already exists called?    
🗑
What is returning a penetrated surface to its original fire-rated integrity called?   Firestopping  
🗑
What are the two major divisions within precabling preparation called?   Planning and Construction  
🗑
A retake of the ITS Technician Level hands-on test may be performed once on the same day if the candidate fails the first time.   True  
🗑
When testing fiber, the attenuation measurement result should always be lower than the ____?   Link Loss Budget  
🗑
6 types of tests used to validate optical fiber   1. Visual Light Source Check 2. VFL (Laser light source) 3. Microscopes 4. OLTS - Optical Loss Test Set 5. Interferometer - inspect end face 6. OTDR - optical time-domain reflectometer  
🗑
VFL Laser operates in what color and range?   Red - 630 - 665nm  
🗑
What tool can aproximate End-to-end attenuation, distance to a point of high attenuation, optical loss per unit, loss per event, and length of the fiber   OTDR (Optical Time Domain Reflectometer)  
🗑
What is the maximum channel length for 10GBase-SX   300m (only achieve with 50/125um L-O fiber)  
🗑
One of the first things you should test in fiber to ensure that a transmitter on one end connects to a corresponding receiver on the other end   polarity or duplex testing  
🗑
For singlemode optical fiber, out of band testing may be accomplished at ____ nm?   1625 nm (pg. 6-71)  
🗑
Component standards typically allow for a variation of ___ dB?   0.2 dB  
🗑
What is the attenuation coefficent for multimode and singlemode OM1, OM2 & OM3 850nm type cable?   3.5 dB/km (pg 6-73)  
🗑
What is the attenuation coefficent for multimode and singlemode OM1, OM2 & OM3 1300nm type cable?   1.5 dB/km (pg 6-73)  
🗑
What is the worst acceptable loss across all mating and joints through connectors in an SCS:   100 percent of connections shall be better than 0.75 dB and 95 percent of the connections shall be better than 0.5 dB. (Ideally ALL products should be better than 0.5 dB per mated connector pair) (pg 6-73)  
🗑
What is the spice insertion loss allowance irregardless of what type of spice it is?   0.3 dB  
🗑
Where is verification of bandwidth of fiber performed?   Only at the point of manufacture of the glass optical fiber  
🗑
What is chromatic dispersion?   the effect of the optical core creating a color change of the signal it is carrying  
🗑
Optical fiber that has been constructed to support VCSEL's will not have bandwidth performache qualities for normal LED's? T/F   FALSE: Optical fiber that has been constructed to support VCSEL's and lasers WILL have bandwidth performance qualities for normal LED's and VCSELs  
🗑
What are the three methods for configuring test equipment and the cable under test using an OLTS?   1. Link 2. Interconnect channel 3. Dual direct connection  
🗑
Paths for light to follow are called (used in cable type name)   modes (multimode fiber)  
🗑
When a pulse of light down a fiber is partially blocked and scattered by microscopic particles (dopants) in the glass.   Rayleigh scattering (like a flashlight in a fog)  
🗑
When light traveling in a fiber passes through a material with different density and is reflected back (often at splice points)   Fresnel Reflection  
🗑
This loss measurement is a fixed percentage of the transmitted light   Backscatter  
🗑
The ratio of backscattered light to transmitted light is also known as the   backscatter coefficient  
🗑
In OTDR Specifications what are the two resolution specifications?   1. Loss Resolution 2. Spatial Resolution  
🗑
Distance using an OTDR is calculated from ?   … the speed of light in the optical fiber  
🗑
Multimode optical fibers work in what bands?   850nm & 1300nm  
🗑
Single mode optical fibers work in what bands?   1310nm & 1550nm  
🗑
What wavelength should fiber be tested at?   The wavelength at which it will be operated  
🗑
What wavelength cable can OTDR test at?   "850nm, 1300nm for multimode and 1310nm & 1550 nm for singlemode"  
🗑
What is the core size for singlemode   8 & 9 nm  
🗑
What is the core size for multimode   50 & 62.5nm  
🗑
Will an optical fiber that has been stressed by bending show a greater loss at the point of bending when tested at 1550nm than at 1300 nm?   Yes  
🗑
How long must the distance range on an OTDR be for testing?   longer than the fiber to be tested  
🗑
What is the rate at which pulses are sent from an OTDR called?   PRR (pulse repetition rate)  
🗑
T/F A long OTDR pulse injects the highest amount of power into the fiber and produces the longest dead zones   TRUE  
🗑
Short OTDR pulse widths are used to quickly find defects and breaks in the cable   FALSE  
🗑
What is the "rule of thumb" for setting pulse width on an OTDR?   long pulse to look long and short pulse to look short  
🗑
T/F A Fresnel reflection occurs at all optical fiber faults   TRUE  
🗑
T/F A measurement of loss per unit distance dB/km is a common method for determining an optical fiber's quality?   TRUE  
🗑
T/F When measuring reflectance return loss a small negative value indicates a larger reflection than a large negative value   TRUE  
🗑
What type of fault is found by an OTDR when two optical fibers of mismatches size are fused?   Gain Splice  
🗑
What type of fault found by an OTDR is when a large reflection occurs in a short optical fiber?   Ghost Reflection  
🗑
If an expected reflection on an OTDR shows up at the half-way mark on the graph, what type of error is likely?   Ghost Reflection  
🗑
What is the typical minimum length of a launch jumper when using an OTDR to test Multimode?   100 m (328 ft.)  
🗑
How long must the launch jumper be when using an OTDR to test singlemode?   It must be longer than the dead zone of the longest pulse width of the OTDR  
🗑
What is another name for automode/autosetup on an OTDR?   Autoranging  
🗑
When two or more waves of the wavelength combine to form a single wave whose amplitude is the sum of the amplitudes of the combined waves it is called:   Lightwave Interference - divided into constructive and destructive interference  
🗑
T/F You must terminate both ends of the optical fiber to achieve an accurate length measurement   TRUE  
🗑
What is the maximum allowable loss in a splice in dB?   0.3 dB  
🗑
These two parts make up the light path of a fiber optic cable   Core and cladding  
🗑
Simplex (single fiber strand) include the following 8 types:   Zip cord, Tight buffered, Distribution, Breakout, Central Tube, Loose tube, Ribbon, Airblown  
🗑
Glass reinforced plastic (GRP) rods, corrugated steel tape, and external steel wire armor (SWA) are all examples of physical protection in what?   Optical fiber jacket layers  
🗑
3 classifications of Optical Fiber Cable?   "Indoor/Outdoor Indoor Outdoor  
🗑
Multimode distance limitation in an SCS?   2000 Meters (6562 ft)  
🗑
Singlemode distance limitation in an SCS?   3000 Meters (9842 ft)  
🗑
Loose-tube optical fiber cable is typically used where?   Outdoors  
🗑
Loose-tube optical fiber cable can be what mode?   Single or multimode  
🗑
This type of Fiber cable is contained within buffer tubes and may be quickly spliced using special equipment.   Ribbon Optical Fiber  
🗑
This type of Fiber cable is installed in a sealed conduit and has an expected operating lifetime of at least 20 years   Air-blown fiber  
🗑
This type of cable allows the jacket to expand and contract without stressing the fiber   Loose-Tube  
🗑
Horizontal optical cable is usually what mode?   Multimode  
🗑
Singlemode fiber sheaths are usually what colors?   Yellow, Red, Blue  
🗑
Multimode fiber sheaths are usually what colors?   Orange, Aqua  
🗑
How much attenuation can a connector add?   up to 1.5db of total attenuation  
🗑
Connector has 3 components   Ferrule, Key, Latching ring  
🗑
4 types of connectors   ST (Straight Tip) SC (Subscriber connector) SFF (Small Form Factor) Array connectors  
🗑
3 types of SFF (Small Form Factor) connectors   LC Connector MU (Multiple Use) LX.5  
🗑
3 instruments typically used to test fiber on the reel   Visual fault locator (VFL) Optical loss test set (OLTS) Optical time domain reflectometer (OTDR)  
🗑
How much service slack should be run into a TR, and how is it typically measured?   Long enough to reach the far corner of the room, plus floor to ceiling with another 3 m (10 ft) of slack inside the cabinet  
🗑
Air pressure for blown fiber is typically in what range?   150-220 psi  
🗑
This type of energy can adversely affect the blowing operation of fiber   Static electricity  
🗑
What are the 2 methods for splicing optical fiber & advantages of each   "1. Fusion - Low consumables cost (lower attenuation) 2. Mechanical - low barrier to entry (higher attenuation)"  
🗑
   
🗑
What are the 3 types of splice?   Straight splice, butt splice, branch arrangement  
🗑
What are the 2 types of connection processes for fiber cable?   "Scribe & Polish And Cleave & Secure"  
🗑
T/F Alignment is much more important in multimode than singlemode connections   FALSE  
🗑
2 primary methods for illuminating the end face when inspecting a cable   "Coaxial - finds scratches and fine details Oblique - clear view of core and cleanliness"  
🗑
T/F cleaning swabs should not be used on Fiber tips as they can scratch them and leave debris   TRUE  
🗑
These three criteria zones prioritize cable inspection evaluation criteria   "Zone A: Core Zone Zone B: Cladding Zone Zone C: Ferrule Zone"  
🗑
What are the 3 transmission methods?   "Simplex Half-Duplex Full duplex"  
🗑
T/F Twisted pair cable is called balanced, Coaxial is called unbalanced   TRUE  
🗑
T/F Voltage is thought of as the quantity of water delivered, while current represents the water pressure   FALSE - Voltage is thought of as the water pressure while current represents the quantity of water delivered  
🗑
Apparent power formula is:   P=VI  
🗑
Peak Power P is shown as watt (W) but is actually:   V times current in amperes (A) or VA  
🗑
What is the Hz rate for North America & The World   60 Hz and 50 Hz  
🗑
What is random unwanted energy that is coupled into a conductor or circuit from an external source called?   EMI  
🗑
What is the disturbance in the reception of radio and other signals because of conflict with undesired signals called?   EMI  
🗑
What are 2 EMF current causes?   High Current (weakens with distance cubed) & Net Current (weakens with distance)  
🗑
What electrical measure is defined as the number of cycles a signal is repeated in a given time period?   Frequency  
🗑
This is the information carrying capacity of a system.   Bandwidth  
🗑
Two types of signal   Analog and digital  
🗑
What is the most common process for voice conversion to digital called?   Pulse Code Modulation (PCM)  
🗑
PCM Samples at what rate / second?   8000 samples / second  
🗑
This defines a measure of signal strength   decibel  
🗑
System gain and attenuation are typically stated as:   Decibel gain or decibel loss  
🗑
An increase or decrease of how much voltage will cause a decibel increase of 10x   20 dB voltage / 10 dB power  
🗑
T/F In the American Wire Gauge system, larger numbers denote larger wires   False - Larger numbers denote smaller wires  
🗑
The basic unit of inductance is   A Henry (H)  
🗑
______ Is a property of conductors that allows storage of electric charges when potential differences *voltages) exist between the conductors   Capacitance  
🗑
Capacitance is measured in___   farads  
🗑
In circuits the total opposition to current flow is called?   impedance  
🗑
The measure of how much a signal is reduced in amplitude (relative power) as it is transmitted over cable is called:   Insertion Loss (Attenuation)  
🗑
This is a ratio in dB of the power of the outgoing signal to the power of the reflected signal   Return Loss  
🗑
The unwanted trasnfer of a singals electromagnetic energy from one or more circuits to other circuits is called?   Crosstalk  
🗑
Three tpes of crosstalk   NEXT FEXT AXT (Alien XT)  
🗑
A ratio fo the speed of transmission along a cable relative to the speed of light in a vacuum (usually stated in percentages)   Nominal Velocity of Propagation (NVP)  
🗑
This is the time interval for a signal to be transmitted from one circuit to another   Propagation Delay  
🗑
This is the difference in the porpagation delay between the slowest and fastest pairs within the same cable sheath   Delay Skew  
🗑
Conductance is inversely related to ____?   resistance  
🗑
For runs over 100m or for all dialectric cabling, what type of cable is recommended?   fiber optic cabling  
🗑
Modal bandwidth is described in terms of   Megahertz x Kilometer (MHz×km)  
🗑
____ results from the different optical path lenghts in a multimode fiber.   Modal dispersion (or modal distortion)  
🗑
___ dispersion begins at the light source   Chromatic  
🗑
___ makes the biggest impression on communication   body language  
🗑
___ makes the biggest impression on communication when talking to the customer   tone of voice and word choice  
🗑
___ and ___ are key to effective customer and coworker relationships   Feedback and Follow-through  
🗑
____ presents an attitude about the quality of work to be performed   Installer's appearance  
🗑
Safety codes often require a ___ when temporary electrical wiring is used   GFCI (Ground fault circuit interrupter)  
🗑
For an extension ladder ___ the horizontal distance from the base of the ladder to the supporting wall should be ___ % of the working length of the ladder.   25%  
🗑
T/F Never paint a ladder   TRUE  
🗑
T/F When operating a scissor lift, you must wear a safety harness   FALSE  
🗑
T/F When operating a boom lift you must wear a saftey harness   TRUE  
🗑
T/F hardhat life span is 5 years   TRUE  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: BobMarley
Popular Computers sets