Imaging Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Question | Answer |
What is the speed of light? | 186,000 miles per second in a vacuum |
What spectrum do x-ray wave energy belong to? Why? | electromagnetic they have electric and magnetic fields associated with them |
What material is typically used in an x-ray generator filament and target? | tungsten |
What is focal film distance? FFD | distance from the focal spot on the tube's target to the film |
What is Object-film distance? OFD | distance from the object being x-rayed to the film |
What are 3 main premises to decrease magnification/image distortion? | 1: use as great an FFD as possible 2: use the minimal OFD as possible 3: place the film and object parallel to each other's long axis and perpendicular to the central useful primary beam |
What are the more radiosensitive cells in the body? | lymphatic young bone cells skin blood-forming tissues immature cells rapidly reproducing cells cells w/increased metabolism |
What are 3 general radiation safety techniques? | 1: avoid the primary beam 2: stand at least 6 feet away from the source to avoid contact with scatter radiation 3: schedule regular testing of the unit to prevent leakage radiation |
What FFD should be used for optimal radiation safety? | Short cone, because they require shorter exposure time |
With what type of film can you reduce exposure time requirements further? | E-speed |
Do dental films use intensifying screens? | no |
What determines film speed? | the size of the silver bromide (halide) crystals in the film emulsion larger crystal-->faster speed |
What is the trade-off for faster speed film? | coarser image, loss of fine detail |
What are two manipulations of the position indicator device PID? | vertical angulation horizontal angulation |
What is the inverse square law? | states that the intensity of radiation required varies inversely with the square of the distance from the source |
according the inverse square law, if the FFD is doubled, and mAP and KVp remain constant, the exposure time must be _____ to maintain the same image | quadrupled |
what is the premise of definition evaluation? | structures ling closest to the film will show better definition than those farther from the film |
What is the SLOB rule AKA Clark's rule regarding tube shift technique? | when the horizontal angulation is adjusted, lingual objects move toward the head and buccal objects move away from the head |
What is the contrast resolution of standard film radiography? Computed tomography? JVD Summer 2013 | 5% vs. 1% |
What is the result of a better contrast resolution of CT compared to standard film radiography? JVD Summer 2013 | CT is more fine tuned, able to ID smaller resolution tissue differences |
What are the 3 main enhancement patterns seen when using IV iodinated contrast medium for a CT scan? JVD Summer 2013 | homogenous, peripheral, & heterogenous |
When comparing MR & CT, what is MR better at? JVD Summer 2013 | provides more accurated info regarding tumor size and invasion of adjacent structures |
When comparing MR & CT, what is CT better at? JVD Summer 2013 | provides best visualization of calcification and cortical bone destruction |
What is a disadvantage of standard film radiography --compared to CT-- when used to evaluate oral tumor? JVD Summer 2013 | extent of bony change is underestimated |
What regional structure is CT particularly good at identifying when tumor involves it, which standard radiography tends to miss? JVD Summer 2013 | orbit |
What is the advantage of CT when evaluating oral tumors? JVD Summer 2013 | CT shows better anatomical detail, structural resolution, & greater bone involvement sensitivity compared to standard radiographs |
In Small dogs, what 2 teeth are most likely to show radiographic abnormalities? JAAHA 2013 | maxillary PM4, mandibular M1 |
In small dogs, what is the most commonly detected radiographic abnormality? JAAHA 2013 | bone loss of any type |
In what age category of small dogs was it most common to see radiographic findings which were not noted on oral exam? JAAHA 2013 | older dogs |
What is the value of 18F-FDG PET/CT as a staging tool for feline oral SCC? Vet Comp Oncol 2013 | soft tissue infiltrative tumors that were subtle and ill defined on CT were highly visible and more extensive on PET/CT. mets were seen as hypermetabolic on PET/CT |
How many shades of gray can the human eye differentiate? How many shades of gray can CTdistinguish? JVD Fall 2013 | Human:20-30. CT 32-60 |
CT is superior for imaging ___ tissues, while MR is superior for imaging ___ tissues when compared to plain film radiology. JVD Fall 2013 | CT: hard/bony, MRI: soft |
Does CT or MRI provide a diagnostic advantage over intraoral rads for detecting periapical abscess? JVD Fall 2013 | no |
What are 2 types of Cone Beam CT detector designs? JVD Spring 2012 | IIT/CCD (image intensifyer tube, charged coupled device) & FPD (flat panel detector) |
What scanning and reconstruction parameters influence imaged quality in CBCT? JVD Spring 2012 | kVp, mA, scan field of view (FoV), patient positioning in the machine |
Which type of CBCT detector design is less complicated, offers greater dynamic range, and has less distortion? JVD Spring 2012 | FPD |
What image artifacts are problematic when using CBCT? JVD Spring 2012 | scatter, beam hardening, metal streaks, increased image noise level, increased inhomogeneity, image density variability, poor soft tissue visibility |
Why was CBCT image quality for cats inferior? JVD Spring 2012 | increased noise level |
What is the typical radiographic finding in puppies with periostitis ossificans? JVD Fall 2010 | double layered ventral mandibular cortex |
Which modality was shown (by Bar-am et al) to be more useful for visualizing the mandibular body and occlusion--CT or RAD? 2008 Vet Surg | Radiography |
Which modality was show to be more useful for IDing anatomic skull structures and maxillofacial injuries in dogs/cats? 2008 Vet Surg | CT |
How much less radiation is used for digital dental radiography compared to traditional dental radiography? JVD spring 2014 | 50-80% less |
EQ: what is the sensitivity and specificity of radiography to diagnose equine dental disorders? | 52-69% and 70-95% (Weller et al 2001, Barakzai 2010) |
What is the gold standard imaging modality for TMJ analysis (in humans)? | MRI |
What are the most common radionuclides used in sku. scintigraphy (for bone tracers)? | Methelene diphosphanate & hydroxymethelene diphosphanate (MDP & HDP) Technetium bound to phosphates |
What is the sensitivity and specificity of scintigraphy? | 95% & 86% |
What is scintigraphy? | The use of a gamma-ray emitting radio isotope which is bound to a tissue seeking molecule |
What is the most commonly used radioisotope in equine scintigraphy? What is it’s half life? | Technetium: Tc-MDP, 6hrs |
What are the two different types of scintigraphic studies? What is the matrix size of each? | Static: 256X 256 Dynamic:128 X 128 |