film processing-DENH
Quiz yourself by thinking what should be in
each of the black spaces below before clicking
on it to display the answer.
Help!
|
|
||||
---|---|---|---|---|---|
What appears on radiographs after being exposed? | show 🗑
|
||||
What does exposure entail? | show 🗑
|
||||
show | they are energized from the radiation
🗑
|
||||
What are the 3 components of processing? | show 🗑
|
||||
show | softens gel, reduces silver halide crystals by precipitation of silver
🗑
|
||||
show | Fixer is acidic and developer is alkalinic
🗑
|
||||
show | reduces silver bromide to silver
🗑
|
||||
show | softens gel to allow hydroquinone to reach silver bromide and maintains alkalinity
🗑
|
||||
show | prevents chemical fog (sometimes)
🗑
|
||||
show | preservative
🗑
|
||||
show | temperature: if high, decrease processing time; if low, increase processing time
🗑
|
||||
show | it needs to be recycled due to the silver
🗑
|
||||
what does sodium thiosulfate do? | show 🗑
|
||||
show | prevents decomposition of thiosulfate
🗑
|
||||
show | shrinks/hardens gelatin (emulsion)
🗑
|
||||
what does acetic acid do? | show 🗑
|
||||
show | double developer time (minimum of 10 min)
🗑
|
||||
show | 3 minutes
🗑
|
||||
what can occur if inadequate fixing happens? | show 🗑
|
||||
show | stops developer, remoes developer so fixer is not contaminated
🗑
|
||||
show | twice as long as it is fixed (minimum 20 min)
🗑
|
||||
show | removes image from film
🗑
|
||||
show | endodontics and post-operative
🗑
|
||||
show | inferior in density and definition to standard method
🗑
|
||||
show | developer, fixer, wash, dryer
🗑
|
||||
show | solution strength, temp, and time = increased quality control
🗑
|
||||
what 3 items need to be recycled? | show 🗑
|
||||
show | size of crystals; larger=faster
🗑
|
||||
show | decrease definition
🗑
|
||||
what is the main advantage of an automatic processor? | show 🗑
|
||||
show | increases, which decreases exposure time
🗑
|
||||
show | 4
🗑
|
||||
PROCESSING SLOUTIONS SHOULD BE CHANGED EVERY? | show 🗑
|
||||
FILM EXPOSURE TEST UTILIZING A "STEP WEDGE" EVALUATES WHAT? | show 🗑
|
||||
EXHAUSTED PROCESSING SOLUTION CAN CAUSE WHAT? | show 🗑
|
||||
WHAT IS THE FASTEST FILM SPEED? | show 🗑
|
||||
LIGHT LEAKS IN THE DARKROOM RESULT IN _____ ON THE FILM. | show 🗑
|
||||
show | DARKER/ MORE RADIOLUSCENT
🗑
|
||||
SILVER BROMIDE CRYSTALS ON A FILM THAT LIES BEHIND A CROWN RECIEVES HOW MUCH RADIATION? | show 🗑
|
||||
A SIMPLE TEST USED TO CHECK THE SAFETY LIGHT IS CALLED? | show 🗑
|
||||
THE MAIN FUNCTION OF LEAD FOIL IN THE FILM PACKET IS TO WHAT? | show 🗑
|
||||
show | INCREASED
🗑
|
||||
TO COMPENSATE FOR THE DECREASE IN IMAGE SHARPNESS THAT RESULTS FROM INCREASING OFD, WHAT IS INCREASED ALSO? | show 🗑
|
||||
show | SHARPNESS
🗑
|
||||
show | DETAIL
🗑
|
||||
show | FOG
🗑
|
||||
show | 16
🗑
|
Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Created by:
564399687
Popular Dentistry sets