Busy. Please wait.
or

show password
Forgot Password?

Don't have an account?  Sign up 
or

Username is available taken
show password

why


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
We do not share your email address with others. It is only used to allow you to reset your password. For details read our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.

Remove ads
Don't know
Know
remaining cards
Save
0:01
To flip the current card, click it or press the Spacebar key.  To move the current card to one of the three colored boxes, click on the box.  You may also press the UP ARROW key to move the card to the "Know" box, the DOWN ARROW key to move the card to the "Don't know" box, or the RIGHT ARROW key to move the card to the Remaining box.  You may also click on the card displayed in any of the three boxes to bring that card back to the center.

Pass complete!

"Know" box contains:
Time elapsed:
Retries:
restart all cards




share
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

doppler principles

basic doppler

QuestionAnswer
doppler shift returned frequency - transmitted frequency
doppler frequency is between.. 2-10MHz
average speed of sound in tissues 1540 m/s
antegrade flow will be above/below the baseline? above
frequency shift is affected by what? transmitted doppler frequency, doppler beam "angle to flow", velocity
Which angle results in a max frequency shift? 0 degree
advantages of CW doppler? detect flow in all vessels, useful for obtaining systolic pressures, No aliasing
what are some ways to eliminate aliasing? ^PRF; decrease freq shift (higher angle or decrease transmitted freq); eliminate triplex
a large SV/gate is related to spatial pulse length
How to generate a color image? autocorrelation
T/F Frame Rate is affected by the density or number of scan lines True: the more lines, the more time to generate an image which decreases frame rate
Power Doppler can be used for what type of flow? Trickle flow
This artifact has been referred to as a "ghost" artery mirror-image artifact
Increasing focal zones increase lateral/axial resolution? Lateral
when the doppler can not differentiate the main sample voume from those of phantoms range gate ambiguity