click below
click below
Normal Size Small Size show me how
Glo Heart Function
| Question | Answer |
|---|---|
| HR>150 increases? | Myocardial demand (MVO2) and can = myocardial ischemia if MVO2>MDO2 (myocardial bld supply) |
| HR>150 decreases? | < diastolic filling time (atrial/ vent filling) = <SV = <CO = < BP = < coronary artery/ organ/ tiss perfusion |
| HR<50 decreases? | <CO = <BP |
| Lose of atrial kick w/ which rythmns? | Afib, Aflutter, junctional, ventricular rythms |
| Atrial kick contributes __%? | 20-30% more bld to vent filling |
| Effects of no atrial kick? | CO may be inadequate = hemodynamic compromise |
| Retrograde depolarization of the atria looks like __ on EKG/ originate where? | - neg P wave, before, during, after QRS- AV, junctional, ventricular, irritable parts of atria --> stimulus not caused by SA |
| HR atria/ junctional/ vent? | 60-100, 40-60, 20-40 |