2010 ADA
ADA Req
| Question | Answer |
|---|---|
| Maneuvering Clearance, Front Approach, Pull Side | 60 inches perpendicular to doorway, 18 inches parallel to doorway |
| Maneuvering Clearance, Front Approach, Push Side (no closer and latch) | 48 inches perpendicular to doorway, 0 inches parallel to doorway |
| Maneuvering Clearance, Front Approach, Push Side (closer and latch) | 48 inches perpendicular to doorway, 12 inches parallel to doorway |
| Maneuvering Clearance, Hinge Side, Pull Side | 60 inches perpendicular to doorway, 36 inches parallel to doorway or 54 and 42 |
| Maneuvering Clearance, Hinge Side, Push Side (no closer and latch) | 42 inches perpendicular to doorway, 22 inches parallel to doorway (beyond hinge side) |
| Maneuvering Clearance, Hinge Side, Push Side (closer and latch) | 48 inches perpendicular to doorway, 22 inches parallel to doorway (beyond hinge side) |
| Maneuvering Clearance, Latch Side, Pull Side (no closer) | 48 inches perpendicular to doorway, 24 inches parallel to doorway (beyond hinge side) |
| Maneuvering Clearance, Latch Side, Pull Side (closer) | 54 inches perpendicular to doorway, 24 inches parallel to doorway (beyond hinge side) |
| Maneuvering Clearance, Latch Side, Push Side (no closer) | 42 inches perpendicular to doorway, 24 inches parallel to doorway (beyond hinge side) |
| Maneuvering Clearance, Latch Side, Push Side (closer) | 48 inches perpendicular to doorway, 24 inches parallel to doorway (beyond hinge side) |
| Toilet Room Size | Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall. |
| Toilet Compartment Size (Wall Hung) | Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum |
| Toilet Compartment Size (Floor Mounted) | Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 59 inches (1420 mm) deep minimum |
| Clear Floor Space | 48 inches (long) x 30 inches (wide) |
| Unobstructed Forward Reach | 15 inches minimum x 48 inches maximum |
| Obstructed Forward High Reach (20 max depth) | 48 inches maximum |
| Obstructed Forward High Reach (20 - 25 max depth) | 44 inches maximum |
| Side Reach (max 10 inches depth obstruction) | 15 inches minimum x 48 inches maximum (can't be higher than 34 inches) |
| Obstructed Side Reach (10 inches x 24 depth) | 46 inches maximum ((can't be higher than 34 inches) |