Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
DH101
ch. 13 wilkins
Question | Answer |
---|---|
3 Types of mirror surfaces | -plane - concave - front surface |
Flat mirror, may produce double image | plane |
Magnifying mirror | concave |
Mirror with reflecting surface is on front surface of lens * front surface eliminates "ghost" images | front surface |
Three parts of a mouth mirror | handle, shank, and working end |
Mirror diameters vary, what are the different diameters | -5/8 inches -1 1/4 inches -1 1/2 inch -2 inch |
Mirrors are threaded 2 different ways | -plain stem -cone socket |
Handles that are better for hygienist | -thicker handles -light weight handles |
Mouth mirror is used for | -indirect vision -indirect illumination transillumination retraction |
Examples of indirect vision | -distal surface of posterior teeth -lingual surface of anterior teeth |
Reflection of light from dental overhead light | indirect illumination |
Reflection of light through the teeth Mirror held to reflect light from lingual aspect while facial teeth are examined | Transillumination |
Name of grasp when holding an instrument | modifies pen grasp |
Air compressor with tubing attachment to syringe | air source |
Has angled working end, can be turned for maxillary or mandibular application | air tip |
Avoid applying air directly into | pocket * subgingival biofilm may be forced into tissues |
Determination of accuracy of instrument by measurement of its variation from a standard | calibration |
Probing depth as measured from the cementoenamel junction, to location of probe tip at coronal level of attached periodontal tissues | clinical attachment level |
Slender stainless steel instrument with fine flexible, sharp point used for examination of surfaces of teeth to detect irregularities | explorer |
A vibration perceptible by palpation | fremitus * determination only on maxillary teeth |
Instrument used to measure mobility | periodontometer |
Smooth, slender instrument usually round in diameter with rounded tip designed for examination of teeth and soft tissues | probe |
Calibrated in millimeter increments to facilitate recordings for comparison with periodic assessments | probe |
Distance from gingival margin to location of periodontal probe tip at coronal border of attached periodontal tissues | probing depth |
Pertaining to the touch | tactile |
Ability to distinguish relative degrees of roughness and smoothness | -tactile discrimination -a.k.a. tactile sensitivity |
Two types of probes are | - traditional or standard manual - automated probes |
Developed and researched in attempt to overcome problems in obtaining consistent readings with traditional probes | automated probes |
Probe is used for | -assess periodontal status -sulcus & pocket survey - determine clinical attachment level - mucogingival exam 5) other gingival determinations 6) guide treatment 7) evaluate success & completeness of treatment 8) evaluation @ maintenance appointm |
A probe has 3 parts | -handle -angles shank working end |
What exam is used for recording perio probe depths | CPE -comprehensive periodontal exam |
Most common probe used is | hu-friedy |
When probe is at base of sulcus or crevice, at coronal end of junctional epithelium | normal health tissue |
When probe tip is within the junctional epithelium | gingivitis and early periodontitis |
When probe tip passes through the junctional epithelium to reach attached connective tissue fibers | advanced periodontitis |
Depth of probing varies around a tooth | true |
Gingival margin varies in its position on the tooth | true |
Proximal surfaces are approached by entering from | both facial and lingual aspects of tooth |
Gingival and periodontal infections begin in the _______ area more frequently than others | col |
Probing depth may be deepest directly under contact area because of | crater formation in alveolar bone |
Anatomic features of tooth surface wall of pocket influence the direction of probing | true |
During movement of the probe ___________ can be felt & evaluated | calculus and tooth surface irregularities |
General factors of probing are | accuracy & consistency so readings are dependable for comparison |
Factors that affect probe determinations are | -severity & extent of perio disease - probe - technique applied - placement problems |
Anatomic variations would be | -tooth contours -furcations -contact areas -anomalies |
Interferences would be | -calculus -irregular margins of restorations fixed dental protheses |
Accessibility/Visibility would be | -obstructed by tissue bleeding -limited opening by patient macroglossia |
Probe insertion with healthy or firm fibrotic tissue | insertion is more difficult because of close adaptation of tissue to tooth surface |
Probe insertion with spongy, soft tissue | gingival margin is loose & flabby because of destruction of underlying gingival fibers. probe inserts readily, bleeding can be expected on gentle probing |
Hold probe tip flat against | -tooth surface -probe is parallel with long axis of tooth for vertical insertion |
Slide probe along tooth surface __________ down to base of sulcus or pocket | vertically |
Maintain probe in sulcus or pocket of each tooth as probe is moved ___________ | in a walking stroke |
Measuring is presence of visible recession | measure from cementoenamal junction to attachment |
Teeth with two roots | bifurcation |
Exam used to detect adequacy of width of attached gingiva, locate frenal attachments & their proximity to free gingiva, identify promptly the mucogingival junction | mucogingival examination |
Area where tension pulls free gingiva away from tooth indicates | no attached gingiva |
General purposes and uses of explorers | -detect texture and character of tooth surfaces -examine supragingival tooth surfaces -examine subgingival tooth surfaces -define extent of instrumentation needed -evaluate completeness of treatment |
Working end of explorer is | slender, wirelike, metal tip that is circular in cross section and tapers to fine sharp point |
Each tooth has ____ readings (areas to be measured) | -6 -3 facial -3 lingual |
Created by:
welchang
Popular Dentistry sets