Limited Operator Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| When were X-rays discovered? | Novemeber 8, 1895 |
| Who discovered X-rays? | Wilhelm Conrad Roentgen |
| Largest radiologic science professional organization - | ASRT |
| Establishes standards and examinations necessary to certify radiologic technologists - | ARRT |
| National organization that formally conducts the accreditation of schools of radiologic technolgy - | JRCERT (Joint Review Committee on Education in Radiologic Technology |
| LXMO | Limited X-ray Machine Operator - the scope of practice is limited compared to registered techonologists |
| Physicians that specialize in interpreting radiographs and preform special imaging procedures - | Radiologist |
| The source of the X-ray Beam - | X-ray Tube |
| The x-ray tube is surrounded by a lead-lined ? | Tube Housing |
| Cross section of the x-ray beam at the point where it is used is called ? | the radiation field |
| An imaginary line in the center of the x-ray beam and perpendicular to the long axis of the X-ray beam - | Central Ray |
| "Unseen" Image | Latenet Image |
| Absorbtion of the X-ray Beam | Attenunation |
| Radiation out side the body that has less engery but is hard to control - | Scatter radiation |
| Causes unwanted exposure to the films and anyone in the room - | Scatter radiation |
| Consists of the x-ray film and film holder | IR (Image Receptor)or Cassette |
| A filmless system that uses digital format with computer technology | CR or Computed Radiography |
| A box like device attached under the tube housing that allows variation in the size of the raditaion field. | Collimator |
| A postition that allows the head to be lowered at least 15 degrees | Trandelenburg Position |
| An oscilating grid under the table top | Bucky |
| T or F The Primary X-ray Beam originates at a tiny point within the x-ray tube | True |
| Unit that represents the rate at which x-rays are produced - | mA or Milliamperage |
| The formula for determining mAs | mA x seconds = mAs |
| Determine the mAs of an exposure made using 300 mA and 0.4 sec | 300 mA x .04 sec = 120 mAs |
| Calculate the exposure time of 50 mA and 40 mAs - | 40 mAs / 50 mA = .8 secs |
| Calculate the mA for the following exposure - 100 mAs and .5 sec | 100 mAs / .5 sec = 200 mA |
| Distance in inches between the radiation source in the x-ray tube and the imaging plane | SID or Source to Image Distance |
| T or F - Raditation intensity is inversly proportional to the square of the distance - | TRUE |
| T or F - kVp is not a useful adjustment for relativly small variations from normal technique | False - kVp IS a useful adjustment for realativly small variations from normal, because large changes in kVp cause significant alterations in appreance. |
| Beloe 85 kVp, and adjustment of ______ will compensate for small changes in part size - | 2 kVp/cm |
| Above 85 kVp, and adjustment of ________ is necessary | 3 kVp/cm |
| For a 2 cm increase in patient part size, increase the mAs by ________% | 30 (multiply the mAs by 1.3) |
| For a 2cm decrease in patient part size, decrease the mAs by _________ % | 20 (multiple the mAs by 0.8) |
| kVp is ________ to lengthen the scale of contrast - | increased |
| Increasing kVp has these effects - | decreases contrast, increases latitude, and creates a GRAYER image |
| kVp is ________ to shorten the scale of contrast - | decreased |
| Decreasing kVp has this effect - | increased contrast, more black and white appearance |