216 RadBio Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| What are the Units of Radiation Measurement | Describes the different units of measurement for radiation depending on what is being measured |
| What is Monitoring of Personnel | Monitoring the radiation dose to anyone who receives an occupational dose 1/10 (10%) of the annual dose limit. |
| Types of Dosimeters | Film Badges Thermoluminescent Dosimeters (TLD) Optically Stimulated Luminescence (OSL) Pocket Dosimeters |
| What is a Dosimetry Report | A report that is generated from the exposure received by the dosimeter while occupationally worn. |
| The Radiation Safety Officer (RSO) responsibility | to retrieve dosimetry report and distribute to employees |
| Dose Limiting Recommendations | recommendations of dose limitations as provided by Radiation Protection Organizations (RPO) |
| What are the Principles of Personnel Exposure Reduction | The guiding principles of reducing the possibility of occupational exposure |
| What are the guiding principles | time, distance, shielding |
| types of fixed barriers | primary and secondary |
| What is the primary barrier | perpendicular to the x-ray beam and are designed to withstand that strength of a full primary beam |
| What is the secondary barrier | barriers around the room designed to absorb scatter radiation |
| Lead apron equivalence | 0.5mm |
| Lead glove equivalence | 0.25mm |
| Thyroid shield equivalence | 0.5mm |
| Lead glasses equivalence | 0.35mm |
| What is the inverse square law | increasing the distance between the source of radiation and the radiographer, the radiation exposure is decreased dramatically |
| What does the inverse square law state | the intensity of radiation at a given distance from a point source is inversely proportional to the square of the distance of the object from the distance |
| How to Reduce involuntary movement | high mA and short exposure time |
| First choice for immobilization assistance | Friend or relative, preferably male |
| Last choice for immobilization assistance | Radiology personnel |
| Never a choice for immobilization assistance | Pregnant Females and Under reproductive age |
| What does Irradiated material mean | the less material or the lower the atomic number, the less interactions will take place and there fore, less scattered photons |
| Main source for scatter radiation | the patient |
| Aperture Diaphragms | Flat piece of lead containing a whole for the CR to pass through |
| Cones | Circular metal structures attached to the tube housing to restrict beam to predetermined size |
| Collimators | Most commonly used beam limitation device; Consists of upper and lower lead shutters at 90 degree angles to each other |
| X-ray Beam Filtration | Filters absorb low energy, long wavelength photons, which improves the quality of the beam |
| 2 types of filtrations | Inherent and Added |
| Inherent filtration | built into x-ray tube |
| Added filtration | added to the design as increased filtration |
| Total Filtration | Inherent and Added filtration combined and must measure at least 2.5 mm Al/Eq |
| When should gonadal shielding be used | when the gonads are in or within 5cm of the primary x-ray beam |
| Who should not use gonadal shielding | anyone within the reproductive age |
| When should you not use gonadal shielding | if it will interfere with any diagnostic information |
| 3 different types of Gonadal shields | Flat Contact Shields Shadow Shields Shaped Contact Shields |
| Laws of Bergonie and Tribondeau | the embryo and fetus are the most radiosensitive stages in human life |
| Lead in the control booth walls | 1/16th in lead |
| Cumulative dose for Radiation worker | age x 10 mSv |
| Annual Effective dose for Occupational Exposure | 50mSv |
| Annual Dose for Lens of the Eyes | 150mSv |
| Annual Eq. Dose for Skin | 500mSv |
| Annual Eq. Dose for Occupational Hands and Feet | 500mSv |
| Effective dose for Pregnant Tech | 5mSv per 9 months 0.5mSv per month |
| Annual Effect Dose Limit for the Public | 1mSv |
| Annual Effective Dose to Lens of Eyes for the Public | 15mSv |
| Annual Effective Dose to the Skin for the Public | 50mSv |
| Maximum leakage from x-ray tube | 100mR/hr @ 3ft(1m) |
| How far should you be able to go with a mobile x-ray | 6ft |
| How long is the primary beam | 7ft |
| barrier thickness depends on | Workload, Use, and Occupancy |
| True or False: Higher metabolic means more radioactive | True |
| Linear Energy Transfer | measures the rate |
| Observation window lead equivalence | 0.3 to 2mm |
| Lead glass window equivalence | 1.5 mm Pb |
| How long should the exposure cord for control booth be | short enough so that an exposure can be made only when the radiographer is entirely behind the control booth barrier while connected to console |
| True or False: Control both walls must be 7ft tall and mounted to the floor | True |
| Required shielding for the protective tube housing | 1.5mm (1/16Pb) |
| What is the protective housing's job | to reduce leakage radiation to an assigned safe level |
| Exposure rate for controlled areas | 100mrem/week |
| Exposure rate for uncontrolled areas | 10mrem/week |
| The NCRP recommends that primary walls barrier be give a use factor of | 1 |
| Pregnancy apron lead equivalence | 0.5mm Pb |
| Thermoluminescent dosimeter | used to monitor radioation exposure to personnel |
Created by:
nishaat
Popular Radiology sets