Airways and Vent Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| Critical Respiratory Assessment Components: what do you assess? | Rate ; WOB ; Depth ; O2 sat ; LOC ; Cyanosis (late sign) |
| What other labs or tests are critical? | ABGS and Chest Xray and Hbg/Hct |
| Preparing for Intubation: what equipments? | Oxygen mask (100% NRB) ; Resuscitation Bag (ambu bag reservoir with oxygen source) ; Endotracheal tube (ETT) (sample) |
| Risks of Intubation ? | Esophageal Intubation ; Right Mainstem intubation ; Ruptured Trachea or Bronchus ; Aspiration of blood or gastric contents ; Tooth damage or loss (and aspiration) ; Hypoxemia ; Tracheal stenosis, erosion, necrosis ; Cardiac arrhythmias |
| ETT Tube to deep what is problem? | right lung intubation |
| How to confirm ETT? | - Auscultate for bilateral breath sounds - measure and secure the tube - confirm by X-ray |
| what is Chemical Restrains Short acting for ETT insert? | Succinylcholine |
| Succinylcholine cause? | causes bradycardia, respiratory depression, apnea and ↑K+ Wears off in about 5 – 7 minutes |
| what is Chemical Restrains long acting for ETT insert? | Vecuronium |
| Vecuronium cause? | watch electrolyte levels, acid base balance and hepatic function before and after administration |
| Indications for Mechanical Ventilation | Respiratory failure due to: ARDS, Pneumonia, CHF ; Respiratory center depression Stroke, head injury, drugs ;Neuromuscular disturbances Guillian-Barre, multiple sclerosis, SCI, myasthenia gravis |
| what are the parameters of the ventilator? | FiO2, tidal volume, pressures such as inspired pressure and positive end expiratory pressure and frequency |
| How big a breath does the vent give or patient take? Tidal volume | appr 6-10ml/kg |
| normal setting rate? | 12-20 |
| Fio2 setting range? | 21-100% |
| PEEP ? | minimum 5-10 |
| PS minimum? | 7-10 |
| PS setting? | 10-30 normal 10-20 |
| Ventilator Adjustments: how to increase Oxygenation? | Increase FiO2 ; Increase PEEP ; Increase PS |
| Ventilator Adjustments: how To increase Ventilation? | Increase Rate ; Increase Tidal Volume |
| what reasons when Ventilator Alarms: for High Pressure | increase airway resistance; decreaselung compliance |
| what reasons when Ventilator Alarms: for Low Pressure ? | Loose tubing connections ; Disconnected circuit ; Extubation |
| what make Increased resistance? | bent ventilator tubing or ETT, excessive water in tubing, excessive secretions, bronchospasm, airway edema |
| what make Decreased lung compliance? | pneumothorax, mainstem intubation, severe atelectasis, ARDS or CHF |