| Term | Definition |
| radiation | energy that travels in waves and is transmitted through space or through a medium |
| energy | has the capacity to do work |
| ionization | any process by which a neutral atom gains or looses an electron |
| 5 forms of energy | 1.) heat 2.) electrical 3.) mechanical 4.) nuclear 5.) electromagnetic |
| roentgen | another name for x-rays Also, (R) the measure of ionization in air which produces 2.08 X 10^9 ion pairs per cc of air |
| light, x-rays, and radiowaves | are all forms of electromagnetic energy |
| MRI | uses radio waves to generate sectional images of patient anatomy |
| November 8th, 1895 | Roentgen discovers x-rays |
| radiographer | person who uses x-rays to create images of the body |
| radiologist | person trained to use nuclear medicine or radiography to produce images of the body for interpretation by a physician |
| ARRT | American Registry of Radiologic Technologists- credentialing organization for medical imaging, interventional procedures, and radiation therapy |
| angiography | examination of the blood vessels after the injection of contrast medium |
| radiopharmaceutical | not contrast medium, radioactive material injected into the bloodstream to visualize organs |
| computed tomography | x-ray visualization of patient anatomy along various sectional planes |
| bone densitometry | dual-energy x-ray absorptiometry; DEXA or DXA. used to diagnose osteoporosis |
| diagnostic medical sonography | ultrasound |
| NMTCB | Nuclear Medicine Technology Certification Board |
| radiologic technology | the technical science using x-rays and radioactive substances to diagnose and treat patients |
| accreditation | the vetting of schools to show compliance with educational standards set by and for the profession |
| JRC | Joint Review Committee- examines educational institutions to determine educational excellence |
| certification | wherein an agency examines the knowledge base of an applicant on a filed of specialized professional skills |
| ARRT | American Registry of Radiologic Technologists- encourages the study and elevates the standard of radiologic technology. |
| JRCERT | Joint Review Committee on Education in Radiologic Technology- accrediting body that established standards of education |
| direct supervision | licensed radiographer is in the room supervising a student |
| indirect supervision | licensed radiographer is within earshot of student and able to respond quickly if needed |
| TJC | The Joint Commission- regulates the quality and safety of care provided to patients |
| NRC | Nuclear Regulatory Commission- conducts site inspections to insure the safe operation of ionizing radiation equipment |
| OSHA | Occupational Safety and Health Administration- federal agency that establishes standards for safety in the workplace |
| HIPAA | Health Insurance Portability and Accountability Act- set standards for the protection of personal health information |
| PACS | Picture Archive and Communication System- acquires, archives, and distributes digital images throughout a particular health system |
| computed radiography | cassette-based, digital- uses photostimulable phosphor plates (PSP) |
| direct capture | uses amorphus slenium- converts x-ray energy to a signal that is sent to a computer for processing |
| half-value layer | amount of filtration necessary to reduce a beam's intensity by half, expressed as (mm Al/Eq) |
| indirect capture | uses amorphus silicon- converts x-rays into light which is detected (by the silicon) and then converted into an electrical signal that is sent to the computer for processing and viewing |
| primary radiation | beam of photons before patient interaction |
| 4 requirements to produce x-rays | vacuum, electron source (filament), voltage to accelerate electrons, target to stop electrons |
| kilovolt peak (kVp) and value range | potential difference that controls the quality and somewhat affects quantity of x-ray photon production- controls contrast- . . . . In radiology, we use 30-150kVp |
| milliampere-second (mAs) and value range | the quantity of photons produced in the tube- controls IR exposure/density. We use 50-400 mA |
| primary radiation | x-rays after leaving tube and before encountering object |
| window level | controls brightness on a display monitor |
| window width | controls contrast on a display monitor |
| penumbra | image unsharpness- the further the OID, the more penumbra there will be |
| scatter radiation | photons that change direction after encountering matter- also known as "fog"-reduced scatter increases contrast as this is non-diagnostic radiation |
| remnant radiation | x-rays that leave the patient and strike the image receptor |
| computed radiography kVp recommended limits | 45-120kVp |
| amorphous silicon (a-Si) | used in indirect capture (remember the i's go together) |
| amorphous selenium (a-Se) | used in direct capture |
| radiographic density | the blackening of an image- controlled by kVp *and* mAs |
| photographic quality | affects the visibility of an image- density and contrast- controlled by kVp |
| geometric quality | affects the sharpness and accuracy of an image- resolution and distortion |
| 4 primary image quality factors | 1.) density, 2.) contrast (photographic quality) 3.) resolution, 4.) distortion (geometric quality) |
| 15% rule | increasing kVp by 15% will effectively double image receptor exposure |
| inverse square law | the intensity of radiation is inversely proportional to the square of the distance from the source |
| exposure latitude | the range of settings that will produce an acceptable image- greater on digital systems |
| exposure indicator | numeric representation of radiation received by the IR digital systems |
| automatic rescaling | computer-controlled display of non-optimal images |
| motion | patient motion is the leading cause of image unsharpness |
| SID | Source to Image (Receptor) Distance- the greater the distance, the greater the recorded detail will be |
| OID | Object to Image (Receptor) Distance- the greater the distance, the more distortion you will have |
| diagnostic yield | amount of clinically useful information on an image |
| anode | positive electrode of the x-ray tube |
| cathode | negative electrode of the x-ray tube |
| diagnostic effacacy | the accuracy of a diagnostic study of a patient's condition |
| ALARA | As Low As Reasonably Achievable- overexposure exceeding 100% above optimum exposure is a ALARA violation |
| bequerel (Bq) | ISU unit of radioactivity- one disintegration per second |
| Curie (Ci) | U.S. unit of radioactivity-quantity of radioactive nuclide that produces 3.7 X 10^10 |
| Gray (Gy) | ISU that measures the amount of energy absorbed in any medium |
| Sievert (Sv) | ISU that measures dose equivalence or biologic effectiveness of differing radiations |
| compton scattering | outer shell interactions- main source of occupational worker exposure, most common effect |
| coherent scattering | below 10keV, does not transfer energy to the patient |
| photoelectric interaction | inner shell ejection of electron, creates an ion pair- greatest hazard to patients, second most common interaction- (remember Patients and Photoelectric) |
| rad | absorbed dose 100 ergs/g |
| rem | dose equivalent- rad X quality factor |
| 3 principals of protection | 1.) time 2.) distance 3.) shielding |
| cultural competency | possessing a set of attitudes, behaviors, and policies that come together in a system to allow interactions in a cross-culteral framework |
| 6 human diversity traits | 1.) mental and physical ability 2.) age 3.) race 4.) national origin 5.) religion 4.) gender and sexual orientation |
| assimilation | process by which one culture gives up their identity and is absorbed into another one |
| biculturalism | the ability to navigate competently between a person's culture and the mainstream one |
| racism | the belief that one's own race is superior to others |
| gender | the chromosomal identity of the person |
| Royce Osborn Minority Student Scholarship | established by the ASRT (American Society of Radiologic Technologists) to increase cultural diversity |
| Maslow's Hierarchy of Needs | Seven levels (from the bottom up): physiological, safety, love, esteem, knowledge, aesthetics, self-actualization |
| paralanguage | non-verbal communication such as the pitch, tone, speed, accent- the quality of your voice, not specifically what was said |
| closed awareness | patient is unaware of the details of their condition |
| suspicious awareness | patient doesn't directly inquire about the details of their condition and pretends to know less than they do know |
| open awareness | full communication between patient and caregivers |
| 5 stages of dying and grief | 1.) denial 2.) anger 3.) bargaining 4.) depression 5.) acceptance |
| advanced directive | orders for care under extreme situations... life support or not |
| localization | determining area of concern by palpation or careful wording of questions |
| 6 techniques for history taking | 1.) open-ended questions 2.) probing questions 3.) facilitation (encouraging attitude), 4.) silence, 5.) repetition (active listening), 6.) summarization |
| acute -v- chronic | acute is sudden onset, chronic has a prolonged course |
| "sacred seven" history taking elements | 1.) onset 2.) localization 3.) chronology 4.) severity 5.) quality 6.) aggravating or alleviating factors 7.) associated manifestations |
| biomechanics | laws of physics as it relates to living bodies |
| center of gravity | S-2 |
| 4 types of wheelchair transfers | 1.) standby assist 2.) assisted standing pivot 3.) two-person lift 4.) hydraulic lift |
| standby assist | wheelchair is at a 45 degree angle to the table |
| assisted standing pivot transfer | wheelchair at 45 degrees from table, uses a belt |
| when moving a patient, | always roll them toward you |
| immobilization | must have doctor's order to immobilize a patient |
| Pigg-o-stat | pediatric restraint device for upright and abdominal radiographs used on children up to about age 4 |
| blanket wrap | triangle folded blanket- goes medially over an arm and then behind the back, then medially over the other arm and gets tucked in behind the back |
| average oral, tympanic and rectal temperatures | Oral- 98.6 Tympanic-97.6 Rectal-99.6 |
| adult and child's respirations <10 yrs old | Adult- 12-20 bpm Child-20-30 bpm |
| adult and child's pulse of <10 yrs old | Adult- 60-100 bpm Child-70-120 bpm |
| blood pressure | systolic <120 mmHg, diastolic <80 mmHg |
| where to take a baby's pulse | radial artery on the thumb side of the wrist |
| bradytachycardia | irregular heartbeat due to age |
| brain damage - oxygen depletion limit | 6 minutes |
| endotracheal tube placement | distal tip 1"-2" above the carina (tracheal bifurcation) |
| pneumothorax and where to intubate | air in the upper pleural spaces, intubate at the second to third intercostal space |
| pleural effusion | fluid in the area surrounding the lungs |
| central venous lines | Broviac, Hickman, Leonard, & Groshong. Tip to be positioned 2cm-3cm above the right atrial junction |
| pulmonary arterial (PA) lines | Swann-Gantz. estimates left ventricular end-diastolic pressure by monitoring right-sided heart and pulmonary pressure. |
| 4 basic infectious agents (+1) | bacteria, viruses, fungi, protozoa... and prions, infectious protein strands |
| 6 steps of infection | 1.) encounter 2.) entry 3.) spread 4.) multiplication 5.) damage 6.) outcome |
| surgical asepsis | 7-8 minute hand washing, sterile technique |
| medical asepsis | 2 minute hand washing, reduces the number of microbes but does not sterilize the area |
| opening a sterile package | always start with the flap that you lift away from you , like a postal envelope |
| enema volume | 1500ml |
| 3 emergency objectives | 1.) preserve life 2.) do no harm 3.) obtain appropriate assistance as quickly as possible |
| defibrillators- automatic -v- semiautomatic | must push button with semiautomatic to deliver shock |
| 4 levels of conciousness | 1.) fully alert 2.) drowsy 3.) unconscious but will react to pain 4.) comatose and unresponsive |
| 4 types of shock and what causes them | hypovolemic- loss of blood cardiogenic- myocardial infarction neurogenic- spinal anesthesia or spinal cord damage vasogenic- sepsis, deep anesthesia, or anaphylactic shock |
| drug | any substance that modifies a living organism's functioning |
| 3 drug classification methods | 1.) by name 2.) by action 3.) by legal classification |
| 7 dose forms | 1.) tablet 2.) capsule 3.) solution 4.) suspension 5.) inhalant 6.) suppository 7.) transdermal patch |
| licensure | the process in which a government agency grants permission to an individual to practice their profession |
| 9 steps of one-person CPR | 1.) establish unresponsiveness 2.) position the patient 3.) 30 chest compressions 4.) open airway 5.) establish breathlessness 6.) rescue breathing 7.) establish circulatory inadequacy 8.) five cycles of 30:2 compressions and breaths @ 100/min 9.) reasses |
| 5 patient rights | 1.) right amount 2.) right drug 3.) right patient 4.) right time 5.) right route |
| radiopaque | decreased density on the view- appear light- positive contrast agent |
| radiolucent | increased density on the view: appears dark- negative contrast agent |
| osomolality | total number of particles in solution. High osmolality solutions pull water towards them. |
| radiopharmaceutical | is not a contrast agent. is taken up by organs in the body and viewed with a gamma camera |
| mild allergic reaction | sneezing, congestion, mildly itchy skin, mild edema, limited vomiting, transient chills or flushing, mild hypertension, headaches, dizziness, anxiety, altered taste- usually does not require treatmnt |
| moderate allergic reaction | facial edema without dyspnea, throat tightness without dyspnea, bronchospasm, diffuse erythema- prompt treatment is required |
| severe allergic reaction | facial edema with dyspnea, diffuse erythema, laryngeal stridor may have hypoxia, anaphylactic shock, arrhythmia, seizures, convulsions- treatment usually requires hospitalization |
| Tc99 | most common radionucleotide in nuclear medicine |
| antimatter | a positive electron. also known as a positron, makes two 511-keV photons when encountering a electron, and is used in PET scans with a gamma camera. |
| ethics | the study of rightness and wrongness of human behavior and character as known by natural reason. Controlled by a group's code of ethics and expulsion is the sanction. |
| beneficence | performs actions or the benefit of the patient (bringing about good) |
| nonmaleficence | never performing acts to harm a patient (preventing harm) |
| autonomy | the patient decides what is to be done with them (acting with self-reliance) |
| veracity | always being relied upon to tell the truth as you know it (telling the truth) |
| fidelity | following through on your commitments (being faithful) |
| justice | performing acts to distribute harm and good equally (acting with equity) |
| ICD-10-CM | coding for a diagnosis |
| CPT-4 | coding for a procedure |
| tort | a claim of injury or wrong being done |
| assault | fear for immediate bodily harm |
| battery | touching a patient without their explicit concent |
| false imprisionment | restraining a patient against their will |
| defamation | slander- speaking badly about someone libel- harmful written comments or pictures |
| fraud | willful misrepresentation of facts that result in the loss of individual right or property |
| negligence | failure to provide reasonable care |
| res ipsa loquitur | "The thing speaks for itself" places the burden of proof on the defendant- used with medical negligence cases |
| respondeat superior | "the master speaks for the servant" an employer being responsible for an employees actions |
| implied consent | cooperating with having a procedure performed |
| informed consent | signed authorization for a procedure |
| what are the 4 vital signs | 1.) pulse rate 2.) respiratory rate 3.) blood pressure 4.) body temperature |
| absorbed dose- traditional and SI unit | rad (traditional) and Gray (SI) |
| dose equivalent (radiation measure) | rem (traditional) and Sievert (SI) |
| activity (radiation measure) | Curie (traditional) and Becquerel (SI) |
| coulomb/kilogram | measure of exposure in air |
| law | controlled by political subdivisions outside of the group. Violations result in fines, imprisonment |
| morals | an individual's internal monitor, derived from religious writings and violation of them results in guilt and shame |
| professional ethics | rules of conduct set out by a group to regulate its members |