ARRT review covering Equipment Operation & Quality Control and Image Acquisition
Quiz yourself by thinking what should be in
each of the black spaces below before clicking
on it to display the answer.
Help!
|
|
||||
|---|---|---|---|---|---|
| 1- misalignment of the tube part IR relationship results in ? | Shape distortion (PAGE. 179 )
🗑
|
||||
| 2- in electronic imaging as digital image matrix size increases? | Pixel size decrease (PAGE. 179 )
🗑
|
||||
| 3- an algorithm as used in X-ray imaging is an ? | Series of variable instructions (PAGE. 179 )
🗑
|
||||
| 4- the component of a CR image plate IP that records the radiologic image is the? | Photostimulable phosphor (PAGE181. )
🗑
|
||||
| 5- the radiation dose received by the digital detector for each image is indicated by the ? | Exposure indicator (PAGE.181 )
🗑
|
||||
| 6- the luminescent light emitted by the PSP is transformed into the image seen on the CRT by the ? | ADC (PAGE. 182 )
🗑
|
||||
| 7- the term windowing describes the practice of ? | Changing the image brightness and/ or contrast scale (PAGE.183 )
🗑
|
||||
| 8- potential digital image post processing tasks include? | Annotation, inversion/ reversal (PAGE. 185 )
🗑
|
||||
| 9- what pixel size has a 612 x 512 matrix with 20 cm field of view FOV ? | 0.04 mm/ pixel (PAGE.185 )
🗑
|
||||
| 10-all the following affect the exposure rate of the primary beam except? A- distance B- kilovoltage C- filed size | Filed size (PAGE.186 )
🗑
|
||||
| 11- term is used describe unsharp edges of tiny radiographic details? | Blur (PAGE. 186 )
🗑
|
||||
| 12- analog to digital conversion is required in the following imaging system? | CR (PAGE.188 )
🗑
|
||||
| 13- for the same FOV, spatial resolution will be improved using ? | A lager matrix (PAGE188. )
🗑
|
||||
| 14- the absorption of useful radiation by a grid is called ? | Grid cutoff (PAGE. 189 )
🗑
|
||||
| 15- exposure rate will decrease with an increase in ? | SID (PAGE. )196
🗑
|
||||
| 16- pathologic conditions probably will require a decrease in exposure factors? | osteoporosis (PAGE.197 )
🗑
|
||||
| 17- as window level increases? | Brightness increases (PAGE. 200 )
🗑
|
||||
| 18- the X-ray image seen on the computer display monitor is ? | Analog image (PAGE.200 )
🗑
|
||||
| 19-requires two exposures to evaluate focal spot accuracy? | Slit camera (PAGE. 203 )
🗑
|
||||
| 20- focusing distance is associated with ? | Girds (PAGE. 203 )
🗑
|
||||
| 21-the processing algorithm represents the ? | Anatomical part and projection (PAGE.204 )
🗑
|
||||
| 22- pathologic conditions would require an increase in exposure factors? | Ascites (PAGE. 207 )
🗑
|
||||
| 23- boxes of film stores in too warm an area may be subject to ? | Film fog (PAGE.207 )
🗑
|
||||
| 24- X-ray film emulation is most sensitive to safelight fog? | During development (PAGE. 208 )
🗑
|
||||
| 25- how often are radiographic equipment collimators required to be evaluated? | Semiannually (PAGE. 209 )
🗑
|
||||
| 26- during CR imaging the latent image present on PSP is changed to a computerized image by ? | ADC (PAGE. 209 )
🗑
|
||||
| 27- exposed silver halide crystals are changed to black metallic silver by? | Reducers (PAGE. 209 )
🗑
|
||||
| 28- examination should 70 kV not be exceeded? | Intravenous urogram (PAGE. 214 )
🗑
|
||||
| 29- What frequency must radiographic equipment be checked for linearity and reproducibility? | Annually (PAGE.259 )
🗑
|
||||
| 30- light sensitive AEC devices are know as ? | Photo timers (PAGE.260)
🗑
|
||||
| 31- the electron cloud within the x ray tube is the product of a process called ? | Thermionic emission (PAGE.261)
🗑
|
||||
| 32- a slit camera is used to measure? | Focal spot size and spatial resolution (PAGE.262)
🗑
|
||||
| 33- circuit devices that permit electrons to flow in only one direction are ? | Solid state diodes (PAGE.262)
🗑
|
||||
| 34- devices converted mechanical energy to electrical energy? | Generator (PAGE.262)
🗑
|
||||
| 35- the type of X-ray tube designed to turn on and off rapidly, providing multiple short, precise exposure? | Grid controlled (PAGE.263)
🗑
|
||||
| 36- the voltage ripple associated with a three phase 12 pulse rectified generator is about ? | 13% (PAGE.263)
🗑
|
||||
| 37- a high speed electron is decelerated as is attached to a tungsten atom nucleus this results in ? | Bremsstrahlung radiation (PAGE.263)
🗑
|
||||
| 38- the procedure whose basic operation involves reciprocal motion of X-ray tube and IR? | Tomography (PAGE.263)
🗑
|
||||
| 39- device is used to control voltage by varying resistance? | Rheostat (PAGE264 )
🗑
|
||||
| 40- the regular measurement and evaluation of radiographic equipment components and their performance is most accurately termed ? | Quality control (PAGE.264)
🗑
|
||||
| 41- as electron impinge on the anode surface, less than 1% of their kinetic energy is changed to ? | X-ray (PAGE.264)
🗑
|
||||
| 42- when the radiographer selects kilo voltage on the control panel which device is adjusted? | Auto transformer (PAGE.264)
🗑
|
||||
| 43- star and wye configurations are related to? | Three phase transformers (PAGE.265)
🗑
|
||||
| 44- congruence of the X-ray beam with the light field is tested using ? | Radiopaque objects (PAGE.265)
🗑
|
||||
| 45-the kV setting on radiographic equipment must be tested annually and must be accurate to within? | +/- 4 kV (PAGE.265)
🗑
|
||||
| 46- the device used to test the accuracy of the X-ray timer is the ? | Spinning top (PAGE. 265 )
🗑
|
||||
| 47- term describe the amount of electric charge flowing per second? | Current (PAGE. 267 )
🗑
|
||||
| 48- which part of an induction motor is located out side the X-ray tube glass envelope? | Stator PAGE.268 )
🗑
|
||||
| 49- functions to increase the milliamperage. | Increase in heat of the filament (PAGE. 269 )
🗑
|
||||
| 50- the most likely produce the highest quality radiographic image ? | High SNR (PAGE. 273)
🗑
|
Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Created by:
kkaljadani
Popular Radiology sets