608 Type II Technician

        Help!  

Question
Answer
Who must get certified?   show
🗑
show Type I, Type II, Type III and Universal  
🗑
Does the EPA require recertification?   show
🗑
Who's responsibility is it to comply to any regulation changes?   show
🗑
show Any high or very high pressure refrigerants.  
🗑
What is considered high pressure refrigerants?   show
🗑
What are typical refrigerants used in high pressure refrigerants?   show
🗑
show Boiling points below -50 degrees F at atmospheric pressure.  
🗑
What are typical refrigerants used in very high pressure refrigerants?   show
🗑
show To reduce the amount of refrigerant in the lubricating oil.  
🗑
show Any device intended to establish connections between hoses, appliances, recovery/recycling machines that is designed to close automatically or manually when connecting or disconnecting to minimize release of refrigerant.  
🗑
What is considered a major repair?   show
🗑
What is a moisture-indicating sight glass used for?   show
🗑
Where do you usually oil foaming?   show
🗑
show Recovery or recycling equipment that is capable of removing refrigerant from and appliance without the assistance of components contained in the appliance.  
🗑
What is a System-dependent Recovery Equipment?   show
🗑
show Refrigerants are classified into safety groups based on toxicity and flammability. That there are six classifications.  
🗑
show A1, A2, A3, B1, B2, B3  
🗑
What does the A or B signify in the ASHRAE Standard 34?   show
🗑
What does the 1,2,or 3 signify in the ASHRAE Standard 34?   show
🗑
show Group A1 refrigerants, machinery rooms shall be equipped with an equipment room refrigerant monitor and it shall actuate and alarm and start mechanical ventilation.  
🗑
show When there is substantial leaks in equipment with charges of greater than 50lbs.  
🗑
show If the Annual leak is 35% or greater.  
🗑
When is comfort cooler chillers and any other equipment required to do repairs?   show
🗑
show Visual inspection, halide torch, electronic or ultrasonic leak detector, soap bubble test, and pressure test.  
🗑
Should you ever use compressed air or oxygen to pressurize a system?   show
🗑
What are the common sources of leaks?   show
🗑
show Knowledge of the function and location of all components of the refrigeration system.  
🗑
show Compressor, condenser, receiver, liquid line, metering device, evaporator, accumulator, and suction line.  
🗑
show HPG/HTG, HPL/HTL, LPL/LTL, supercooled liquid, LPG/LTG, and Superheated Gas  
🗑
show If, due to leaks, the required evacuation level is not attainable, or substantially contaminate refrigerant  
🗑
show That recovery devices made after November 15, 1993 has to be certified by a third party EPA approved lab.  
🗑
What should you do before recovering refrigerant from an appliance?   show
🗑
What has to be done if you are recovering R134a from an appliance?   show
🗑
What is the quickest method of recovery to recover liquid from the high side?   show
🗑
show Will decrease oil loss.  
🗑
When doing a recovery, what should be recovered first and what is last?   show
🗑
show By cooling the cylinder with ice.  
🗑
Why should you use caution when the recovery device has a refrigerant cooled hermetic compressor?   show
🗑
What should you do once the required recovery vacuum level has been reached?   show
🗑
show Check the recovered refrigerant for contamination. Check oil sample to see if the unit had a compressor burnout.  
🗑
show Cause trapped moisture to freeze.  
🗑
While evacuating you notice a lot of moisture present, what should you do?   show
🗑
show It should remove moisture from the refrigerant.  
🗑
What is DOT reg 49 CFR?   show
🗑
show DOT approved  
🗑
show Leak check the device, check and change oil if needed, know the refrigeration systems refrigerant, assure the vacuum pump is capable of pulling 500 microns, and check service valve positions.  
🗑
When should you not energize a compressor?   show
🗑
show High discharge pressure  
🗑
show Pressure Regulator  
🗑
show Functioning pressure relief device.  
🗑
show Replace it  
🗑
show In Parallel to the system.  
🗑
show An alcohol spray.  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: DooleyDiesel