ARRT registry review covering Image Production and Evaluation

Quiz yourself by thinking what should be in each of the black spaces below before clicking on it to display the answer.
        Help!  

Question
Answer
An increase in added filtration will result in a ______ in x-ray intensity and a _______ in effective energy of the x-ray beam.   decrease, increase Buschong p146  
🗑
What is the direction of electron travel in the x-ray tube?   cathode to anode Buschong p122  
🗑
What technical changes would best serve to remedy the effect of very dissimilar tissue densities?   high-kilovoltage exposure factors Buschong p273  
🗑
Where is the focal-spot blur the greatest?   at the cathode end of the x-ray beam Buschong p287  
🗑
What is the reduction in x-ray photon intensity as the photon passes through material?   attenuation Buschong p185  
🗑
What radiographic instruments are used to measure the thickness of body parts in order to determine optimal selection of exposure factors?   calipers Buschong p 308  
🗑
The slit camera test requires two exposures to evaluate ______ and accuracy?   focal-spot Buschong p462  
🗑
Two types of exposure-time artifacts are_______ and ______?   double exposure and motion Buschong p473  
🗑
What is the continued emission of light by a phosphor after the activating source has ceased?   phosphorescence Buschong p221  
🗑
What imaging a body part over 4 inches and using a high kilovoltage, what sort of radiographic equipment can be employed to produce a better image?   Grid Buschong p248  
🗑
Differential absorption is related to pathology and ________.   subject contrast Carlton p245  
🗑
Greater latitude is available to radiographers in film/screen imaging when they use ________ factors.   high-kilovoltage Carlton p185  
🗑
If 16 mAs was used to produce a particular x-ray image, what new mAs value would be required to produce a similar image if the kVp was increased by 15%   8 mAs Buschong p254  
🗑
When the light field goes pass the body as in a lateral lumbar, what can be done to prevent excessive density due to undercutting?   use lead rubber to absorb primary radiation on tabletop Carlton p233  
🗑
What is used to express the resolution of a diagnostic image?   line pair per millimeter (Ip/mm) Carlton p334  
🗑
What is used to express resolution/recorded detail?   Modulation transfer function Carlton p334  
🗑
As the CR laser scanner/reader recognizes the photostimulated luminescence released by the PSP storage plate, it constructs a graphic representation of a pixel value distribution. This is a?   histogram Carlton p361  
🗑
Improved recorded detail and heat capacity can be achieved with an anode with a _______ angle.   small Buschong p139  
🗑
High signal-to-noise is most likely to produce a _____-quality image?   high Buschong 112  
🗑
True or False: Beam restriction improves spatial resolution?   False Buschong p243  
🗑
Geometric unsharpness is affected directly by?   OID Carlton p444  
🗑
The scale of contrast becomes longer as grid ratio _______.   decreases Carlton p432  
🗑
With the anode heel effect, the intensity of the x-ray beam is greatest at?   the cathode end of the beam Carlton p407  
🗑
Radiographs made with parallel grids show decreased density on their lateral edges from?   decreased SID Carlton p260  
🗑
Using 600mA and 0.02sec would be more helpful to control voluntary or involuntary motion?   involuntary motion Carlton p451  
🗑
On CR imaging, the latent image present on the PSP is changed to a computerized image by:   the analog to digital converter (ADC) Carlton p358  
🗑
Grids being off-center can cause_______ which would result in overall loss of density.   grid cutoff Carlton p257  
🗑
When a radiologic technologist uses a SID of 25-30 inches with a 14X17 IR, it is likely to:   increase the anode heel affect Carlton p407  
🗑
Luminescent light that is emitted by the PSP gets transformed into the image on the CRT by:   ADC Carlton p357  
🗑
What layer of the CR image plate records the radiographic image?   photostimulable phosphor Carlton p357  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: pmbraswell1
Popular Radiology sets