Save
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

Rad Protection Ch.13

Compurted Tomography & mammograms

QuestionAnswer
Because _____ uses multiple slices during images and the x-rays do not "cut off" at the edge of the slice, there are some overlap and therefore and increased in exposure to that area. CT.
Direct Patient Shielding - Not typically used in CT. - Rotational nature of exposure. - Beam tightly collimated to the slice. - Generally, in CT, anatomy does not appear in the primary beam unless it is part of the intended field of view.
Spiral, or helical, CT - Presents a greater challenge for assessing patient dose. - Spiral scan pitch ratio.
_____ reduces patient dose because the x-rays are spread out over a larger area or the movement of the patient through the beam is quicker. Higher pitch.
Tube Current Modulation - Compared to Automatic Exposure Control in radiographic imaging. - Reduces the amount of radiation through areas which do not require as much exposure. - Based off of the "scout view.
In order to approximate the effective radiation dose to a patient who has undergone a CT study the following CT dose parameters need to be determined: - CT dose index (CTDI). - CTDIw. - CTDIVOL. - Dose length product (DLP).
Mammography Is used to detect breast cancer that is not palpable in physical examinations.
Patient Dose in Mammography - Age considerations for mammography. - Mean dose to the glandular tissue of a 4.5-cm compressed breast using a screen-film or digital mammography system per FDA should not exceed per view 3 mGyt . - Benefit of digital mammography units.
Mammography Screening - American College of Radiology (ACR), American Cancer Society (ACS), and American Medical Association (AMA) advocate annual screening at least every other year for women age 40 to 49 years.
Filtration for Mammographic Equipment Molybdenum or Rhodium filter.
Dose reduction on mammography can be achieved by limiting the number of projections taken. - For routine screening procedure, it is prudent to perform only craniocaudal and mediolateral projections of each breast with adequate compression to demonstrate breast tissue uniformly from the nipple to the most posterior portion.
Created by: sassyrad
Popular Radiology sets

 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards