Save
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

RADT 465 Image Prod.

ARRT registry review covering image production

QuestionAnswer
The fixed spatial resolution characteristic of direct digital systems is termed by what? TFT & DEL size (Lange Q&A p. 167)
An algorithm, as used in x-ray imaging, is/ are what? A series of variable instructions (Lange Q&A p.167 )
The part of a detector element (DEL) that stores electrical charges is the Capacitor (Lange Q&A p.168 )
Grid cutoff due to off-centering would result in what? Overall loss of receptor exposure (Lange Q&A p. 169)
The postprocessing function that removes high frequency noise from an x-ray image is Smoothing (Lange Q&A p.169 )
If an IR exposed using a 12:1 ratio grid exhibits loss of signal at its lateral edges, it is probably because why? SIF was too great (Lange Q&A p.169 )
What can foreshortening be caused by? The radiographic object being placed at an angle to the IR (Lange Q&A p.169 )
The device that functions that terminates the x-ray exposure following ionization of a particular quantity of an air is the AEC (Lange Q&A p.170 )
The primary function of x-ray beam filtration is to Reduce patient dose (Lange Q&A p.171 )
What part of the detector element (DEL) that functions as a switch/gate to release charges for readout is the TFT (Lange Q&A p.171 )
What device is used to overcome severe variation in patient anatomy or tissue density, providing more uniform receptor exposure? Compensating filter (Lange Q&A p.172)
The distance between the center of one pixel and the center of an adjacent pixel is termed what? Pixel pitch (Lange Q&A p.173 )
Because of the anode heel effect, the intensity of the x-ray beam is greatest at Cathode end of the beam (Lange Q&A p.173)
Analog-to-digital conversion is required in which of the following imaging system? A larger field matrix (Lange Q&A p.173)
For the same field of view (FOV), spatial resolution will be improved using A larger matrix (Lange Q&A p.173 )
In what way does SID affect sharpness of an images detail? Image detail sharpness is directly related to SID (Lange Q&A p.175 )
The quality assurance term used to describe consistency in exposure at adjacent mA station is Linearity (Lange Q&A p.175 )
What factors impact spatial resolution? Focal spot size, subject motion, and SOD (Lange Q&A p.175 )
How are milliampere seconds and patient dose related? Milliampere seconds and patient dose are directly proportional (Lange Q&A p.176 )
What is an example of a pathologic condition that would require a decrease in exposure factors? Emphysema (Lange Q&A p.176 )
What pixel size has a 512X512 matrix with a 20cm field of view (FOV)? 040mm/pixel (Lange Q&A p.176 )
Foreshortening of the radiographic image is a result of what? Improper part alignment (Lange Q&A p.177 )
Misalignment of the tube-part-IR relationship results in what? Shape distortion (Lange Q&A p.177 )
Exposure rate will decrease with an increase in SID (Lange Q&A p.178 )
As digital image matrix size increases what happens? Pixel size decreases (Lange Q&A p.178 )
What can distortion be caused by? Tube angle, the position of the organ or structure within the body, and the radiographic positioning of the part (Lange Q&A p.178 )
Decreasing field size from 14x17 inches to 8x10 inches, with no changes will? Decrease the amount of scattered radiation generated within the part (Lange Q&A p.178 )
Reduction in x-ray photon intensity as it passes through numerous tissue densities is termed Attenuation (Lange Q&A p.179 )
Scattered radiation can impact the image negatively, but has no effect on Spatial Resolution (Lange Q&A p.179 )
The material comprising the IP front must be Homogeneous/ radiolucent (Lange Q&A p.180 )
OID is related to image sharpness/ spatial resolution in which of the following ways? Sharpness/ resolution is inversely related to OID (Lange Q&A p.180 )
The purpose of the electroconductive layer of a CR-PSP plate is to Facilitate transportation through the scanner/reader (Lange Q&A p.180 )
What pixel has a 2048x2048 matrix with a 60cm FOV? -0.3mm (Lange Q&A p.180 )
As window width increases what happens? Brightness decreases (Lange Q&A p.180 )
Ionizing radiation intensity decreases as Distance from the source of radiation increases (Lange Q&A p.180 )
The radiographic accessory used to measure the thickness of body parts to determine optimal selection of exposure factors is the Caliper (Lange Q&A p.181 )
The x-ray image is seen on the computer display monitor is a/an Analog image (Lange Q&A p.181 )
A radiograph made with a parallel grid demonstrated decreased receptor exposure on its lateral edges. This is most likely due to what? Decreased SID (Lange Q&A p.181 )
As digital detector element (DEL) size decreases Spatial resolution increases (Lange Q&A p.182 )
An increase in kilovoltage will serve to Increase photon energy (Lange Q&A p.182 )
The maximum spatial resolution in digital imaging is equal to the Nyquist frequency, which is 1/2 x the pixel pitch (mm) (Lange Q&A p.183 )
The processing algorith represents the Anatomical part and projection (Lange Q&A p.183 )
The relationship between the height of a grid's lead strips and the distance between them is called grid Ratio (Lange Q&A p. 183)
What are advantages of high kilovoltage chest radiography? Reduces patient dose & exposure time can be shorter (Lange Q&A p.183 )
The line-focus principle expresses the relationship between what? The actual and the effective focal spot (Lange Q&A p.184 )
Why is a short exposure time essential in chest radiography? To imimize involuntary motion (Lange Q&A p.185 )
The term windowing describes the practice of Changing the image brightness and/or contrast scale(Lange Q&A p.186 )
In digital imaging, thin film transistor (TFT) and detector element (DEL) size is related to Spatial resolution (Lange Q&A p.186 )
A compensating filter is used to Even out widely differing tissue densities (Lange Q&A p.187 )
The ratio of the pixel's sensing area to the area of the pixel itself refers to Fill factor (Lange Q&A p.187 )
Created by: 18Fieldsms
Popular Radiology sets

 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards