Busy. Please wait.
or

show password
Forgot Password?

Don't have an account?  Sign up 
or

Username is available taken
show password

why


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
We do not share your email address with others. It is only used to allow you to reset your password. For details read our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
Don't know
Know
remaining cards
Save
0:01
To flip the current card, click it or press the Spacebar key.  To move the current card to one of the three colored boxes, click on the box.  You may also press the UP ARROW key to move the card to the "Know" box, the DOWN ARROW key to move the card to the "Don't know" box, or the RIGHT ARROW key to move the card to the Remaining box.  You may also click on the card displayed in any of the three boxes to bring that card back to the center.

Pass complete!

"Know" box contains:
Time elapsed:
Retries:
restart all cards
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

RAD 121

Imaging 2 Problem Solving

QuestionAnswer
Describe the formula to calculate geometric unsharpness. P = FSS x OID / SOD
Describe the formula to calculate magnification based on distances. %M = SID - SOD / SOD x 100
Describe the formula to calculate magnification based on object and image. MF = IW / OW
Describe the relationship between the formulas to calculate magnification factor. MF = SID / SOD = IW / OW
Describe the formula to calculate the percentage of magnification based on distance. % magnification = SID - SOD / SOD x 100
Describe the formula to calculate the percentage of magnification based on object and image. % magnification = IW - OW / OW x 100
Describe the formula to calculate grid ratio. GR = Height (lead strips) / Distance ( between lead strips)
What is the relationship of the generator to beam creation? 1 phase 1 pulse generators are much less efficient than the latest 3 phase 12 pulse generators. 1 phase 1 pulse = output factor 1 1 phase 2 pulse = output factor 2 3 phase 6 pulse = output factor 3 3 phase 12 pulse = output factor 4
Describe the grid conversion factor based on grid ratio. a) No Grid = 1 b) 5:1 = 2 c) 6:1 = 3 d) 8:1 = 4 e) 10:1 and 12:1 = 5 f) 15:1 and 16:1 = 6
How do you maintain receptor exposure when adding, changing, or omitting a grid? mAs1 / mAs 2 = GF1 / GF2