click below
click below
Normal Size Small Size show me how
retro cystoureth
retrograde cystourethrography test
| Question | Answer |
|---|---|
| Where do we center for a scout? | 2” above the upper border of the pubic symphysis |
| Pt position AP axial | pt. supine, MSP centered |
| CR entry for AP axial | 10-15 degrees caudad to the center of the IR 2” above the PS (to place the PS below the bladder) |
| Pt position for PA axial | prone, MSP centered |
| CR entry for PA axial | 10-15 degrees cephalad entering 1” distal to the coccyx |
| CR entry if prostate is of interest on PA axial | 20-25 degrees cephalas |
| CR angulation for voiding studies | perpendicular |
| What scale of contrast are contrast studies? | short |
| PT orientation RPO/LPO | supine, rotated 40-60 degrees |
| Position of cassette for RPO/LPO | centered 2” above PS, 2” medial to uppermost elevated ASIS |
| Position of cassette for RPO/LPO voiding | 2” medial to the ASIS at the PS |
| Pt position for lateral | lateral recumbent |
| Placement if IR for lateral | centered 2” above the upper border of the PS at the MCP |