Busy. Please wait.
or

show password
Forgot Password?

Don't have an account?  Sign up 
or

Username is available taken
show password

why


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
We do not share your email address with others. It is only used to allow you to reset your password. For details read our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
Don't know
Know
remaining cards
Save
0:01
To flip the current card, click it or press the Spacebar key.  To move the current card to one of the three colored boxes, click on the box.  You may also press the UP ARROW key to move the card to the "Know" box, the DOWN ARROW key to move the card to the "Don't know" box, or the RIGHT ARROW key to move the card to the Remaining box.  You may also click on the card displayed in any of the three boxes to bring that card back to the center.

Pass complete!

"Know" box contains:
Time elapsed:
Retries:
restart all cards
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

radt 465

image aquisition

QuestionAnswer
which IR gets image by photon hitting scintillator> light> CCD> electronic signal CCD / CMOS
negatives of what IR are low light capture, lack of transfer efficiency and spatial resolution, decreased DQE CCD/ CMOS
which IR uses uropium, barium fluorohalide phosphors, CR, workstation PSP
DQE INCREASES SO PATIENT DOSE ________ DECREASES
PHOTO> AMORPHOUS SELENIUM> SILICON> XRAY> LIGHT TFJ> LIGHT A Si> LIGHT TFT
PHOTON > PHOSPHOR LAYER> LASER RELEASES> LIGHT > NORMAL STATE> READER OF LIGHT> DIGITIZER PSP
POSITIVES: HIGH CONTRAST, LIGHT WEIGHT : ___ IR PSP
EI ________ PROPORTIONAL TO EXPOSURE OF IR DIRECTLY
S NUMBER _____- PROPORTIONAL TO EXPOSURE OF IR INVERSELY
ABILITY OF SYSTEM TO DISPLAY CHANGES IN GRAY SCALE VALUES (BIT DEPTH) CONTRAST RESOLUTION
MEASURED IN LP/ MM DETERMINED BY PIXEL SIZE SPATIAL RESOLUTION
CR USES ___________ FOR SPATIAL RESOLUTION SAMPLING FREQUENCY
DR USES _____ FOR SPATIAL RESOLUTION DETECTOR ELEMENT SIZE (DEL)
IODINE STUDIES NEED ______ KVP <80
BARIUM STUDIES USE __________ KVP 100- 125
DOUBLE CONTRAST STUDIES USE ______ KVP 90-100FA
PROCESOR TIME? 90 SEC
FILM STORAGE TEMPERATURE 50-70 DEGREES
PROCESSING TEMPERATURE 90-95 DEGREES
ARTIFACTS THAT OCCUR AFTER EXPOSURE ARE WHAT COLOR BLACK
WHEN PT THICKNESS INCREASES 1 CM WHAT ADJUSTMENT TO KV 2 KVP
PHOTON ENERGY LEVEL IS INVERSELY PROPORTIONAL TO ______ WAVELENGTH
_________ IMAGING HAS SOLID STATE DETECTOR, DIRECT CAPTURE IMAGING SYSTEM, IMMEDIATE IMAGE DISPLAY DR
A HIGH RATIO GRID WILL ABSORB MORE OR LESS SCATTER AND ABSORB MORE OR LESS PRIMARY MORE
DOES FIELD SIZE AFFECT EXPOSURE RATE NO
EXPOSURE RATE DECREASES AS ________ INCREASES SID
SCATTERED RADIATION CAUSES WHAT ON AN X RAY FOG
FACTORS THAT AFFECT CONTRAST KVP, GRIDS, FILTRATION, IMAGING SYSTEM SPEED, ANATOMY AND PATHOLOGY
CONTRAST AND KVP ARE ______ PROPORTIONAL INVERSELY
ANATOMY AND PATHOLOGY _______ PROPORTIONAL TO IMAGE CONTRAST INVERSELY