SPC Mech Vent Wean
SPC Mechanical Ventilation Weaning Parameters
Question | Answer |
---|---|
VC | >10-15 ml/kg |
Ve | <10 l/m |
Vt | >300mL & <700mL |
RR | <25bpm |
MIP/NIP | -20 to -30 cmH2O |
RSBI | <100 |
Cd | >25 ml/cmH2O |
Vd/Vt | < 60% |
% Shunt | < 20 to 30% |