Save
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

Equipment Op/QC

QuestionAnswer
The type of x-ray tube designed to turn on and off rapidly grid-controlled
The electron cloud within the xray tube is the product of a process called thermionic emission
What causes pitting, or melting, of the anode's focal track repeated, frequent overloading
What are the ion chambers in the bucky for AEC
Congruence of the xray beam with the light field is tested using radiopaque objects (pennies)
What converts electrical energy into mechanical energy motor
The essential function of a phototimer is to terminate the exposure once enough xrays have hit the IR
The device that receives teh remnant beam, converts it into light and increases brightness is what image intesifier
What occurs during Bremsstrahlung radiation production The electron slows and changes direction
What system functions to compensate for changing patient thickness during fluoro Automatic brightness control
When the radiographer selects kilovoltage what device is being adjusted autotransformer
As electrons impinge on the anode surface, less than 1% of their energy is turned into what xrays
What is the device that directs the light emitted from the image intensifier to various viewing and imaging apparatus beam splitter
The xray tube in a CT imaging system is associated with pulsed xray beam
The device used to change alternating current to unidirectional current is solid state diode
The image intensifier tube's input phosphor functions to convert xrays to light
What is the formula for determining heat units for a three phase 12-pulse xray mA X time X kV x 1.41
Which of the following terms describes the amount of electric charge flowing per second Current
What part of an induction motor is IN the glass envelope rotor
what functions to increase milliamperage increase heat at filament (more electrons burned off)
A photostimulable phosphor is used with CR
Created by: jfwoodard
Popular Radiology sets

 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards