Save
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

RADT 465: Equipment

Equipment Operation and Quality Control

QuestionAnswer
The type of x-ray tube designed to turn on and off rapidly, providing multiple short, precise exposures, is (pg. 279 #2) Grid-Controlled
Typical examples of digital imaging include (pg. 279 #3) MRI, CT, CR
What circuit deices operate on the principle of self-induction? (pg. 279 #5) Autotransformer, Choke coil
If a high-voltage transformer has 100 primary turns and 50,000 secondary turns and is supplied by 220 V and 100 A, what are the secondary voltage and current? (pg. 280 #7) 200 mA and 100 kV
When using the smaller field in a dual-field image intensifier (pg. 280 #9) The image is magnified
The minimum response time of an automatic exposure control "AEC" (pg. 280 # 10) Is its shortest possible exposure time
What are some characteristics of the x-ray tube? (pg. 281 #13) The target material should have a high atomic number and a high-melting point, the useful beam emerges from the port window, the cathode assembly receives both low and high voltages
Congruence of the x-ray beam with the light field is tested using (pg. 281 #18) Radiopaque objects
Delivery of large exposures to a cold anode or the use of exposures exceeding tube limitation can result in (pg. 281 #19) Cracking of the anode, rotor-bearing damage
As window level increases (pg. 282 #22) Brightness increases
Which of the following is/are components of the secondary, or high voltage, side of the x-ray circuit (pg. 282 #23) Rectification system
A backup timer for the AEC serves to (pg. 282 #25) Protect the patient from overexposure, protect the x-ray tube from excessive heat
A slit camera is used to measure (pg. 282 #28) Focal-spot size, spatial resolution
What will improve the spatial resolution of image-intensified images? (pg. 283 #30) A very thin coating of cesium iodide on the input phosphor and a smaller diameter input screen
The advantages of collimators over aperture diaphragms and flare cones include (pg. 283 #31) The variety of field sizes available and more efficient beam restriction
The voltage ripple associated with a three-phase, six pulse rectified generator is about (pg. 283 #35) 13%
A high speed electron entering the tungsten target is attracted to the positive nuleus of a tungsten atom and, in the process, is decelerated results in (pg. 284 #37) Bremsstrahlung radiation
What is used in digital fluoroscopy, replacing the image intensifier's television camera tube? (pg. 284 #40) Charge-coupled device
A three-phase timer can be tested for accuracy using a synchronous spinning top. The resulting image looks like (pg. 284 #41) Solid arc, with the angle (in degrees) representative of the exposure time
The procedure whose basic operation involves reciprocal motion of the x-ray tube and film is (pg. 284 #43) Tomography
When the radiographer selects kilovoltage on the control panel, what device is adjusted? (pg. 284 #45) Autotransformer
Star and wye configurations are related to (pg. 284 #46) Three-phase transformers
What is the device that directs the light emitted from the image intensifier to various viewing and imaging apparatus? (pg. 285 #47) Beam splitter
What contributes to inherent filtration? (pg. 285 #49) X-ray tube glass envelope, x-ray tube port window
All of the following x-ray circuit devices are located between the incoming power supply and the primary coil of the high-voltage transformer (pg. 285 #53) The timer, kilovoltage mete, and autotransformer
Disadvantages of moving grids over stationary grids include which of the following? (pg. 286 #55) They can prohibit the use of very short exposure times and they increase patient radiation dose
The functions of a picture archiving and communication system (PACS) include (pg. 286 #56) Acquisition of digital images and storage of digital images
How many half-value layers will it take to reduce and x-ray beam whose intensity is 78 R/min to an intensity of less than 10 R/min (pg. 286 #57) 3
The kV setting on radiographic equipment must be tested annually and must be accurate to within (pg. 286 #58) +/-4 kV
An incorrect relationship between the primary beam and the cneter of a focused grid results in (pg. 286 #59) Grid cutoff and insufficient radiographic density
The x-ray tube in a CT imaging system is most likely to be associated with (pg. 286 #60) A pulsed x-ray beam
Conditions that contribute to x-ray tube damage include (pg. 287 #62) Lengthy anode rotation and exposures to a cold anode
The total brightness gain of an intensifier is the product of (pg. 287 #63) Flux gain and minification gain
What information is necessary to determine the maximum safe kilovoltage using the appropriate x-ray tube rating chart? (pg. 287 #64) Milliamperage and exposure time and focal spot side
A spinning top device can be used to evaluate (pg. 287 #65) Timer accuracy and rectifier failure
The device used to change alternating current to unidirectional current is (pg. 287 #67) A solid state diode
If the distance from the focal spot to the center of the collimator's mirror is 6 in., what distance should the illuminator's light bulb be from the center mirror? (pg. 287 #68) 6 in.
Deposition of vaporized tungsten on the inner surface of the x-ray tube glass window (pg. 288 #72) Acts as additional filtration
With what frequency must radiographic equipment be checked for linearity and reproducibility (pg. 289 #79) Annually
Exposures less than the minimum response time of an AEC may be required when (pg. 289 #86) Using high milliamperage and using fast film screen combinations
Which of the following isare associated with magnification fluoroscopy? (pg. 290 #87) Higher patient dose than nonmagnification fluoroscopy, higher voltage to the focusing lenses, and image intensifier focal point closer to the input phosphor
Advantages of battery powered mobile x-ray units include their (pg. 290 #88) Ability to store a large quantity of energy and ability to store energy for extended periods of time
What modes of the trifield image intensifier will resul in the highest patient dose? (pg. 290 #89) 12 inch mode
The AEC device can operate on which of the following principles (pg. 290 #92) A photomultiplier tube charged by a fluorescent screen and a parallel plate ionization chamber charged by x-ray photons
Which of the following functions to increase the milliamperage (pg. 290 #93) Increase heat of the filament
If 92 kV and 15 mAs were used for a particular abdominal exposure with single phase equipment, what milliampere-seconds value would be required to produce a similar radiograph with three-phase 12 pulse equipment (pg. 290 #94( 7.5
Fractional focus tubes with a 0.3 mm focal spot or smaller, have special application in (pg. 290 #95) Magnification radiography
Which of the following devices is used to control voltage by varying resistances? (pg. 292 #100) Rheostat
Which of the following combinations will offer the greatest heat loading capacity? (pg. 293 #108) 10 degree target angle, 1.2 mm actual focal spot
Which of the following would be appropriate IP front materials? (pg. 293 #109) Magnesium and Bakelite
How often are radiographic equipment kV settings required to be evaluated (pg. 293 #110) Annually
Accurate operation of the AEC device depends on (pg. 294 #113) Positioning of the object with respect to the photocell and beam restriction
The image intensifier's input phosphor generally is composed of (pg. 294 #114) Cesium iodide
Created by: rdwilliams1
Popular Radiology sets

 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards