Radiology lab Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| What is the optimum temperature for manual developing? | 68F |
| If you are processing a film manually and the temperature if 72F,will you need more or less time to develop? | Less time |
| If you are manually processing a film and the temperature is 65F, will you need more or less time to process? | more time |
| What is the optimum temperature when processing in the machine? | 82F |
| What is the function of fixer? | Clears the emulsion off the film that has been developed.and hardens the emulsion* |
| T/F manual processing is sensitive to time and temperature | True |
| T/F- Solutions for the machine are made to be used in warmer temperatures than manual processing and in less time | True |
| What is a dark room? | A safe place to develop radiographs |
| What color is the safelight, generally? | Red |
| T/F- The xray film is sensitive to the blue/ orange light,but it is less sensitive to red | FAlSE- It Is sensitive to Blue/Green and less sensitive to red/orange light spectrum. |
| the film is most sensitive to what colors? | Blue/ Green |
| In the color spectrum: Red/Orange are the furthest away from what other colors? | Green/Blue |
| The optimum distance from the counter with the film, to the safe light is? | 4 feet |
| How does overdeveloped film appear? | dark- more dense |
| How does underdeveloped film appear? | light-less dense |
| T/F- To underdevelop and overdevelop are processing errors | TRUE |
| What can cause a dark film? | (1)overprocessing (2)solution too warm (3) |
| What can cause an underdeveloped film? | not long enough in the developer solution |
| What factors affect the life of a solution? | (1)oxidation- natural slow down (2)volume-Number of films processed (3)Temperature- too hot/cold (4) Chemical Contamination |
| How often should the solutions be changed? | 3-4 weeks |
| T/F- Over time the developer depletes, it must be replenished with concentrated solution. Do not dilute | TRUE- the solutions should not be diluted |
| How is the size of the size of the Halide crystals related to the speed of the film? | XXXXX |
| In the film packet. What is the purpose of the lead foil? | stops |
| T/F- The Inverse Square Law states that the further away from the source of radiation the less intense the beam. | TRUE- distance from source is inversely proportional to intensity of beam. |
| According to the Inverse Square Law, which distance is better for the patient 8" or 16"? | 16"- less divergent rays, more parallel rays, less intense beam |
| For the Inverse Square Law what do you divide by and what do you multiply by? | Divide by 4 and multiply by 4 |
| T/F- If only part of the fil got developer and then the whole film is fixed, How will that part of the film not developed look? | clear* |
| What will happen if Lori, by mistake, dipped the film into the fixer and after into the developer. How will that film appear? | clear |
| What is the purpose for taking BWS? | Interproximal exam for: caries, crest of bone, calculus |
| Generally, how many BWS are taken? | 4BWS |
| Generally, what size film is used? | Size 2 |
| What is latent image? | The invisible image after exposure and before processing |
| Name the 5 steps in manual processing: | (1)Developer(2)Rinse(3)Fixing(4)washing(5)Drying |
| Name the 4 steps in automatic processing: | (1)Developer(2)Fixing(3)Washing(4)Drying |
| What is the function of the developer? | (1)Reduces black metallic silver (2)Precipitates black metallic silver (30 softens the emulsion |
| T/F- Developer and Fixer are basic solutions. | False- Developer is basic / Fixer is Acid |
| Why are the yellow-brown stains produced on the film? | not enough time fixing/ not enough rinsing |
| What may cause a blank film? | (1)not exposed; machine off,broken machine(2)fixer 1st,then developer(3) |
| What causes a superimposed film? | Metal appears radioopaque- metal appliance not removed |
| Define Film Processing: | A series of steps that produce a visible image on a dental radiograph |
| What are the end results of film processing: | (1)converts latent(invisible) image to visible image. (2)Preserves image |
| How is a latent image created? | Silver halide crystal absorb xradiation during xray exposure & store the energy, then the stored energy forms a pattern & creates an invisible image within the emulsion |
| Quantity of xray penetration & halide exposure through Air/soft tissue: | Many xrays penetrate/ many halides exposed |
| Quantity of xray penetrattion & halide exposure through Bone: | Fewer xrays penetrate/ fewer halides exposed |
| Quantity of xray penetration & halide exposure through amalgam/gold: | Few if any xrays penetrate/ no exposed silver halide |
| What is reduction? | when during processing the portion of the exposed,energized halide is removed. |
| What is the result of reduction? | exposed silver halides results in precipitated black metallic silver. |
| The first step in developing is? | Developing |
| In film processing, the rinsing step is necessary because: | Rinsing removes the developer from the film and stops the development process |
| The film emulsion is hardened during: | Fixation |
| The hydroquinone in the developer brings out the ___(1)___ tones, whereas the Elon in the developer brings out the______(2)_______ tones on a dental radiographs | (1)black (2)gray |
| The optimal temperature for the developer solution is: | 68F |
| The size of a darkroom is determined by what factors? | (1)volume of radiographs processed (2)Type of processing equiptment used (3) Space requirements for duplication of films (4) number of persons using the room |