Physics Test 2 Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| answer | question |
| the routine, periodic evaluation of an ultrasound system to guarantee optimal image quality | |
| ACR (American college of radiology) | Who accredits the lab? |
| Two (semiannually) | How many times a year does the ACR accredit the labs? |
| True (helpful by heating muscles) | True or false, bioeffects are helpful in therapeutic applications in ultrasound |
| Grayscale, scattering, and attenuation (but test objects do not) | What do TE phantoms check? |
| True | True or false, test objects test the beam profile |
| True | True or false, sonographers can use phantoms |
| Graphite filled aqueous gel or urethane rubber materials which are closest to soft tissue attenuation and propagation speed | What are TE phantoms made of? |
| 1.54 mm/us | What is the propagation speed in gels? |
| gray scale, tissue texture, multifocus, and adjustable focus phased array transducers | What can TE phantoms evaluate? |
| testing of detail and contrast resolutions, penetration (depth), dynamic range, and TGC operation | TE phantoms stimulate tissue properties, allowing for what? |
| False | True or false, test objects stimulate tissue characteristics |
| Flow and gate location | What does doppler test object tests? |
| gas bubbles | What is a disadvantage of TE/Doppler phantoms |
| Hydrophone | What measures output? |
| The membrane is made of PVDF (polyvinylidene fluoride) | What are hydrophones made out of? |
| Anything that deals with pulse; PRP, PRF, PD, duty factor, amplitude, & intensity | What can a hydrophone measure? |
| Total power in a sound beam (heating) | What does the calorimeter measure? |
| Automated probe tester | How does an individual transducer get tested? |
| Dosimetry | The science of identifying and measuring the characteristics of an ultrasound beam that are relevant to bioeffects |
| "cause and effect" | Mechanistic |
| "exposure and response" | Empirical approach |
| as low as reasonably achievable (low power, low time) | What does ALARA stand for |
| plants | What do they test cavitation on |
| In vivo | What types of tests are within the living body of a plant or animal |
| In virto | What type of tests are performed outside the living body in an artificial environment ie cells outside the body |
| focused | Which is less dangerous, an unfocused beam or a focused beam? |
| 1W/cm2 | No bioeffects have been noted in a focused beam intensities below _____________ |
| 100 mW/cm2 (.1 watt) | No bioeffects is an unfocused beam with intensities below ______________ |
| 0.3 MPa | (MI) No bioeffects with peak rare fractional pressures below ________ |
| absorption (conversion of ultrasound to heat) | What is attenuation primarily due to |
| 2 | Temperature rises are significant if they exceed _____ degrees C |
| bone | What part of the body has highest absorption coefficient |
| 50 | For exposure duration up to _____ hours, there have been no significant bioeffects |
| Cavitation | The production and behavior of bubbles in a liquid medium |
| Stable | What type of cavitation describes bubbles that oscillate in diameter |
| Transient | What type of cavitation describes bubbles that are so large that they collapse |
| MI (mechanical index) | High pressure makes bubbles shrink. Low pressure (rarefraction) bubbles expand and burst |
| at peak rarefraction pressures (high negative pressures) and low frequencies | When does cavitation occur |
| FDA | Who regulates the ultrasound equipment |
| AIUM | Who makes the statements about prudent use of diagnostic ultrasound that benefits outweighs the risk, if any, to be present |
| False (schools are research are okay to use) | Ultrasound should only be used when there is a clinical benefit, true or false? |
| Epidemiology | A branch of medicine that uses population studies |
| Spectral doppler are the highest, then M mode and color doppler, and grayscale outputs are the lowest | What has higher output, spectral doppler or gray scale? |
Created by: