RADT 465 Image Prod Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| 1. What does window level adjust? (pg 314) | Brightness |
| 2. What refers to the various body tissue densities and thicknesses? (pg 314) | Subject contrast |
| 3. True or False: mAs has an impact on contrast (pg 315) | False |
| 4. According to what law does exposure rate decrease when SID is increased? (pg 315) | Inverse square law |
| 5. As distance is decreased, intensity of the beam increases, therefore what adjustment should be made? (pg 316) | an increase in mAs |
| 6. Kv affects what 2 things? (pg 317) | quality and quantity (energy/wavelength) |
| 7. According to what rule does mAs need to be cut in half when increasing Kv by 15%? (pg 317) | 15% rule |
| 8. What 3 factors determine scatter radiation production? (pg 318) | field size/beam restriction, kV, thickness/volume and density of tissues |
| 9. What is the most important way to decrease the production of scatter? (pg 321) | collimation |
| 10. What is a device that is used between the patient and IR that functions as absorption of scatter before it reaches the IR? (pg 321) | Grid |
| 11. When should grids be used? (pg 321) | when imaging a body part 10 cm or greater |
| 12. When using a grid, what should you do to your technique? (pg 321) | increase mAs |
| 13. True or False: you should angle against the lead strips when using a grid (pg 323) | False |
| 14. True or False: your tube and grid should be parallel to each other (pg 323) | True |
| 15. What type of grid error has occurred if there is a loss of exposure at the periphery of the IR? (pg 324) | off-focus |
| 16. What type of grid error has occurred if there is uniform loss of exposure across the IR? (pg 324) | off-center |
| 17. True or False: grid cutoff will not occur if you place your grid upside down (pg 324) | False |
| 18. What is the height of the lead strips compared with the distance between them? (pg 325) | Grid ration |
| 19. How much filtration does the primary beam have? (pg 328) | 2.5 mm Al (glass envelope 0.5 mm, collimator 1.0 mm, added 1.0 mm) |
| 20. What is the purpose of filtration? (pg 328) | removes the diagnostically useless xray photons that contribute only to pt dose |
| 21. True or False: filtration has no impact on contrast (pg 328) | True |
| 22. Destructive pathologic conditions include: (pg 331) | osteoporosis, osteomalacia, pneumoperitoneum, emphysema, degenerative arthritis, and atrophic and necrotic conditions |
| 23. Additive pathologic conditions include: (pg 331) | ascites, rheumatoid arthritis, paget's disease, pnuemonia, atelectasis, congestive heart failure, and edematous tissue |
| 24. When using the anode heel affect, which side does the thicker part of the pt go under? (pg 332) | Cathode |
| 25. What is the smallest unit of computer data? (pg 334) | bit |
| 26. What is a two-dimensional element that is measured in the XY direction? (pg 334) | pixel |
| 27. What refers to the # of bits per pixel and identifies the grayscale? (pg 334) | bit depth |
| 28. What is the graphic representation of pixel value distribution? (pg 334) | histogram |
| 29. What is the volume of tissue in each pixel and is measured in the Z direction? (pg 334) | voxel |
| 30. What does window width adjust? (pg 334) | the shades of grey |
| 31. What is defined as how readily the anatomic details can be perceived? (pg 336) | visibility |
| 32. What is defined as how easily we are able to recognize those details? (pg 336) | contrast resolution |
| 33. Where is the ionization chamber located and how does it operate? (pg 338) | under the table, above the IR and as photons emerge from the pt they enter the chamber and ionize the air within |
| 34. Where is the phototimer located and how does it operate? (pg 338) | under the IR and exit radiation from the pt interacts with and exits the IR and emits light and charges the photomultiplier tube |
| 35. What factors affect resolution? (pg 350) | OID, SID, focal spot size, distortion, patient shape/position, and motion |
| 36. Contrast resolution is measured in (handout) | lp/mm |
| 37. What is an adjustment of pixel values to pre-set range of values to produce consistent brightness and grayscale called? (handout) | Rescaling |
| 38. What is a kernel used to average out neighboring pixels and fill it in called? (handout) | Dead pixel correction |
| 39. What is the opposite of smoothing, used to bring out small details, increases contrast, and could make noise more visible? (handout) | Edge enhancement |
| 40. What is the removal of darkest to lightest pixel value from greyscale called? (handout) | equalization |
| 41. What suppresses visible noise and will lose some contrast varying pixels across an image? (handout) | smoothing |
| 42. What is defined as stored histogram values of selected exams? (handout) | LUT |
| 43. What is used to shield viewer eyes from area outside of collimated field should the computer not automatically place black surround? (handout) | masking |
| 44. What is defined as using grid lines from a special wire alignment grid to align multiple images into one? (handout) | stitching |
| 45. Equalization is also known as what? (handout) | dynamic range compression |
| 46. True or False: masking should not be used to collimate anatomy that should not haven been captured | True |
| 47. What is it called when you even out pixel values across an entire image for consistent brightness? (handout) | flat fielding |
| 48. As DQE increases, what happens to patient dose? (handout) | it decreases |
| 49. What is the numeric value that represents the amount of exposure the IR receives? (handout) | EI |
| 50. What is the difference between fixed and variable technique charts? (handout, pg 339) | fixed: specifies a particular Kv for adequate penetrating and requires a change in mAs based upon patient size and condition. variable: mAs is fixed and Kv is increases as part thickness increases. |