| Term | Definition |
| Cathode | A negatively charged electrode that produces electrons in the x-ray tube. |
| Anode | A positively charged electrode in the x-ray tube consisting of a tungsten target that produces x-rays when hit with electrons from the cathode. |
| ALARA | As Low As Reasonably Achievable, program placed by the National Committee on Radiation Protection ensuring that radiation exposure is as low as possible by wearing PPE and using non-manual restraint for veterinary patients. |
| Kilovoltage Peak (kVp) | The maximum voltage applied across an x-ray tube that determines the energy of the electrons produced. |
| Heel Effect | Visible differences in the density produced on a radiograph; there is greater radiation intensity on the cathode side because of the angle of the target on the anode side. |
| Radiographic Density | The degree of blackness on a radiograph. |
| Milliamperage (mA) | The current produced by the x-ray tube during an exposure. |
| Contrast | Is defined as the differences in radiographic density between adjacent areas on a radiographic image. |
| Radiolucent | Air on a radiograph turn dark or black, it allows more of the radiation to pass through. |
| Radiopaque | Will appear white with more dense tissue as it absorbs more radiation. |
| Penumbra Effect | Causes loss of detail and results in collimation. |
| Source-Image Distance (SID) | Distance between the source of the x-ray and the film. (Interchangeable with FFD). |
| Film-Focal Distance (FFD) | Distance between the source of the x-ray and the film. (Interchangeable with SID). |
| Object-Film Distance (OFD) | The distance from the object being imaged to the recording surface. (Digital Imaging) |
| Object-Image Distance (OID) | The distance from the object being imaged to the recording surface. |
| Bucky | Puts the grid in motion as the x-rays are generated, blurring the white grid lines on the radiograph. |
| Collimators | Consists of adjustable lead shutters installed in the tube head of the x-ray machine. |
| Focused Grids | Have lead strips placed at progressively increasing angles to match the divergence of the x-ray beam |
| Latent Image | The invisible image in the emulsion of an x-ray film produced after the film has been exposed to light. |
| Anechoic | Used to describe tissue that transmits all the sound through to deeper tissue. |
| Annular Ray | Arranges the crystals in concentric rings. |
| Direct Exposure Film | Is more sensitive to direct x-rays than it is to light. |
| Distance Enhancement | Occurs when the sound beam traverses a cystic structure. |
| Echoic | Means that most of the sound is reflected back to the transducer |
| Film latitude | The films inherent ability to produce shades of gray. |
| Fluoroscopy | Used for those patients who visualization of dynamic structures is of importance. |
| Hyperechoic | Used to describe tissues that reflect more sound back to the transducer than surrounding tissues. |
| Hypoechoic | Used to describe tissues that reflect less sound back to the transducer than surrounding tissues. |
| Intensifying Screens | Contain fluorescent crystals bound to a cardboard or plastic base. |
| Isoechoic | Used to describe tissue that appears to have the same echotexture on the screen as surrounding tissues. |
| Maximum Permissible Dose (MPD) | The National Council on Radiation Protection and Measurements recommends that the dose for occupationally exposed persons not exceed 5rem/yr. |
| Mirror Image | Artifact creates the illusion of the liver on the thoracic side of the diaphragm or the appearance of a second heart beyond the lung interface. |
| Roentgen Equivalent In Man (Rem) | Rem units are used to express the dose equivalent that results from exposure to ionizing radiation. |
| Sievert (SV) | Is the current terminology used to define a rem (1 Sv = 100rem) |
| Slice Thickness | When the transducer receives echoes with different amplitudes from the same area at the same depth. |
| Sonolucent | Means that most of the sound is transmitted to the deeper tissues, with only a few echoes reflected back to the transducer. |
| Ultrasonography | Diagnostic Ultrasound is a noninvasive method of imaging soft tissues. |
| Bisecting Angle Technique | A radiographic technique in which the film is placed as close to the intended tooth as possible. |
| Parallell Technique | A radiographic technique in which the film is placed in the mouth parallel to the teeth and the cone is aimed perpendicular to the film and tooth. |