RADT 465 Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| What is the voltage ripple for a 3 phase 6 pulse generator? | 13% |
| What is the voltage ripple for a 3 phase 12 pulse generator? | 3-4% |
| What is the voltage ripple for a high frequency generator? | <1% |
| What is the voltage ripple for 1/2 wave and full wave generators? | 100% |
| How often should lead apron checks be done? | annually |
| What are the input phosphor sizes? | 25 cm, 17 cm, 12 cm |
| What are input phosphors made of? | cesium iodide |
| What is the average output phosphor size? | 1-2.5 cm |
| What are output phosphors made of? | cadmium sulfide |
| How do you decrease magnification without using the mag mode button? | increase SID, decrease OID |
| What is the brightness gain formula? | minification x flux gain |
| What is the magnification factor formula? | input1/input2 |
| What kind of interaction is caused by the energy from slowing down of electrons that produces an x-ray | Brehmsstrahlung |
| Which interaction can produce an x-ray from any kV? | Brehmsstrahlung |
| The binding energy released from an outer shell electron that produces an x-ray is what type of interaction? | Characteristic |
| As frequency ______, wavelength _______ and energy _______ | increases, decreases, increases |
| What is radiation that exits the tube? | primary radiation |
| What is radiation that exits the patient? | remnant radiation |
| How often should CR cassettes be erased? Cleaned? | erased every 24-48 hours; cleaned monthly |
| inverse square formula | I1/I2 = (d2)squared/(d1)squared |
| heat unit formula | kVp x mA x seconds x generator x # of exposures taken |
| unsharpness formula | filament size x OID/SOD |
| positive density every 3.14" perpendicular to the direction of film travel for 1" roller | pi lines |
| appear as scratch lines parallel to direction of film travel separated by 1-2" | guide shoe marks |
| How often should fluoroscopy output be tested? | every 6 months |
| What type of exams would have a type 1 histogram? | hand, foot, ankle, pelvis |
| What type of exams would have a type 2 histogram? | abdomen |
| What type of exams would have a type 3 histogram? | contrasted studies, prosthetics, metal hardware |
| Where is the range for the exposure indicator number found? | between S1 and S2 on a histogram |
| Where is the VOI/ROI found on a histogram? | between S1 and S2 on a histogram |
| As DQE _________, patient dose goes __________ | increases, decreases |
| EI is ____________ proportional to exposure of the image receptor | directly |
| S-number is __________ proportional to exposure of the image receptor | inversely |
| What is the ability of a digital system to display changes in gray scale values-bit depth? | contrast resolution |
| What is the ability of a system to record adjacent small structures? | spatial resolution |
| What is optimal kVp for extremities-peds? | 60-70 |
| What is optimal kVp for small extremities? | 64 |
| What is optimal kVp for medium extremities? | 72-76 |
| What is optimal kVp for large extremities? | 80-86 |
| What is optimal kVp for small parts of the skull? | 76 |
| Where all digital images are stored | PACS, picture archival communication system |
| Order entry, patient demographic information; frequently integrated with PACS and sometimes HIS/EMR | RIS, radiology information system |
| What is optimal kVp for skull (general)? | 90 |
| What is optimal kVp for abdomen, pelvis, lumbar? | 90 |
| What is optimal kVp for vertebral column (C&T spines)? | 86 |
| What is optimal kVp for nongrid/grid? | 86/120 |
| What is optimal kVp for barium based contrast media studies plain/double contrast? | 120/100 |
| What is optimal kVp for iodine based contrast media studies? | 80 |
| Patient demographic information, billing, supplies, order entry for testing | HIS, hospital information system |
| Patient medical charts | EMR/EHR, electronic medical record/electronic health record |
| Standard developed to interconnect medical digital imaging devices | DICOM, digital imaging and communications in medicine |