RDTC 118 Unit 4 Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| WTF is this? | No Shit Sherlock |
| An image with few densities but many differences between them has ___ Contrast? | High Contrast (Short Scale) |
| An image with many Blacks and Whites, with few grays? | High Contrast |
| An image with many densities but little difference between them has ___ Contrast? | Low Contrast (Long Scale) |
| An image with many shades of Gray? | Low Contrast |
| #1 Controlling Factor of Contrast? | kVp |
| How is Digital Contrast controlled? | kVp, but altered by Computer |
| ↑ kVp = __ Transmission | ↑ Transmission |
| ↑ kVp = __ Compton Interactions | ↑ Scatter |
| ↑ kVp = __ Photoelectric Effect | ↓ Absorption |
| ↑ kVp = __ Fog | ↑ Fog |
| ↑ kVp = __ Contrast | ↑ kvp = ↓ Contrast |
| Low kVp has more of what type of Interactions? | Low kVp = ↑ Photoelectric Absorption |
| Contrast Influencing Factors | Grids, Collimation, OID, Anatomic Part, Filtration |
| ↑ kVp = __ Scatter | ↑ kVp = ↑ Scatter |
| ↑ Grid Ratio = __ Scatter = __ Contrast | ↑ Grid = ↓ Scatter = ↑ Contrast |
| ↑ Collimation = __ Tissue Exposure = __ Contrast | ↑ Collimation = ↓ Tissue Exposure = ↑ Contrast |
| ↑ OID = __ Scatter = __ Contrast | ↑ OID = ↓ Scatter = ↑ Contrast |
| Do we adjust OID for contrast? Why or why not? | No, ↑ Contrast but also ↑ Distortion |
| How does increasing OID increase Contrast? | "air gap" of OID allows Scatter to Miss the IR (↓ Scatter = ↑ Contrast) |
| ↑ Tissue Thickness = __ Scatter = __ Contrast | ↑ Tissue = ↑ Scatter = ↓ Contrast |
| ↑ Tube Filtration = __ Scatter = __ Contrast | ↑ Filtration = ↑ Scatter = ↓ Contrast |
| How does Tube Filtration decrease Contrast? | Filtration absorbs low energy photons that increase beam intensity and in turn Scatter (↑ Scatter = ↓ Contrast) |
| Result of kvp and absorption characteristics of anatomic tissue? | Subject Contrast |
| Result of manufacturing properties and processing conditions? | Film Contrast |
| _____ changes Absorption Characteristics of tissue by ↑ or ↓ Beam ____ ? | Contrast Medium, Attenuation |
| (-/+) Contrast Agents increase beam attenuation and produce less film density? | + Contrast Agent = More Absorption/Increased Brightness |
| (-/+) Contrast Agents increase transmission? | Negative Contrast Agents (Air) |
| (+/-) Contrast Agents require increase in exposure factors? | Positive Contrast Agents (Barium) |
| Film Processing temperatures outside Normal will ↑ or ↓ Contrast? | ↓ Contrast |
| kVp changes for ages below 6? | -15% kVp |
| Minimum kVp for Premies | 50 kVp |
| Minimum kVp for Infants | 55 kVp |
| Minimum kVp for Child | 60 kVp |
| mAs adjustment for ages 0-5? | 25% (75% less) |
| mAs adjustment for ages 6-12? | 50% mAs of adult |
| What types of casts do not require technique changes? | Fiberglass |
| Dry vs Wet theory for technique adjustment with Plaster Cast? | Dry = 2x mAs Wet = 3x mAs |
| Alternate theory for technique adjustment with Plaster Cast? | Treat cast as increase in Part Thickness |
| ____ Diseases increase absorption characteristics of part, making it more difficult to penetrate? | Additive Diseases |
| Examples of Additive Diseases | Ascites, Cirrhosis, CHF, Pleural Effusion |
| ____ Diseases decrease absorption characteristics of part, making penetration easier? | Subtractive Diseases |
| Examples of Subtractive Diseases | Bowel Obstruction, Free Air, Emphysema |
| Which type of diseases may need an increase in kVp? | Additive Diseases |
| When would you visualize soft tissue on an image? | Foreign body, Croup, Obstruction |
| Which exposure factor do you change when soft tissue needs less Density to visualize the area of interest? | ↓ mAs = ↓ Density |
| Which exposure factor do you change when soft tissue needs a change in Contrast to visualize the area of interest? | ↑ or ↓ kVp |
| Geometric Properties control ____ ? | Sharpness |
| ____ is the distinctness or sharpness of the structural lines that make up the recorded image? | Recorded Detail |
| 3 Factors of Geometric Unsharpness | OID, SID, Focal Spot Size |
| Another term for Geometric Unsharpness | Penumbra |
| Penumbra | Area of unsharpness or blurred margin |
| Focal Spot Size only affects ____ ? | Recorded Detail |
| Small focal spot size | .5-.6 mm |
| Large focal spot size | 1-1.2 mm |
| ↑ SID = __ Unsharpness = __ Recorded Detail | ↑ SID = ↓ Unsharpness = ↑ Recorded Detail |
| How does increasing SID increase Recorded Detail? | Xray photons more perpendicular to IR/Object with greater SID |
| ↑ OID = __ Unsharpness = __ Recorded Detail | ↑ OID = ↑ Unsharpness = ↓ Recorded Detail |
| Factor with #1 impact on Unsharpness? | OID |
| Optimal recorded detail when OID is ___ ? | zero |
| How do you compensate for unavoidable OID? | ↑ SID sligthly |
| Calculating Distance Formula | SID = OID + SOD |
| Geometric Unsharpness Formula | Geometric Unsharpness = (Focal Spot Size x OID)/SOD |
| Better recorded detail with (High/Low) Unsharpness value? | Lowest # is Better Detail |
| ↑ Film Speed = __ Recorded Detail = __ Unsharpness | ↑ Film Speed = ↓ Recorded Detail = ↑ Unsharpnes |
| High film speed reduces radiation required but at the expense of __ ? | Less dose but Lower Recorded Detail |
| Unsharpness caused by patient motion? | Motion Unsharpness (Blur) |
| Ways to control motion... | 1. Short exposure 2. Clear Communication 3. Immobilize |
| ____ is the imaging system's ability to distinguish btwn two adjacent structures? | Resolution |
| ____ is the smallest detail detected on the image? | Spatial Resolution |
| ____ is the imaging system's ability to distinguish btwn small objects with similar subject contrast? | Contrast Resolution |
| Resolution is expressed in what unit of measure? | Line pairs per millimeter (Lp/mm) |
| Define Line Pair | One metal line + space = Line Pair |
| ___ is the misrepresentation of size or shape? | Distortion |
| Shape Distortion where the part is misaligned? | Foreshortening |
| Shape Distortion where the CR or IR is misaligned? | Elongation |
| Another term for Size Distortion? | Magnification |
| ___ has the greatest effect on Size Distortion? | OID |
| ↑ OID = __ Size Distortion | ↑ OID = ↑ Magnification |
| Parts Closest to the IR will have more size distortion (T/F)? | False - Further Away more Distortion |
| ↑ SID = __ Size Distortion | ↑SID = ↓ Mag/Size Distortion |
| ___ indicates how much Size Distortion is on an image? | Magnification Factor |
| Magnification Factor Formula (Size) | MF = Image Size / Object Size |
| Magnification Factor Formula (Distance) | MF = SID / SOD |
| % of Magnification Formula | % Mag = {(Image Size-Object Size)/Object Size} x100 |
| To calculate Image/Object Size, 1st Calculate ___ ? | Magnification Factor (MF) |
| Image/Object Size Formula | Object Size = Image Size/MF |