RADT 465: Image Eval Word Scramble
![]() R E E L D E P V O
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Question | Answer |
What is the correct order of radiographic film processing? | Developer, fixer, washer, dryer (Saia, Lange Q&A, pg. 209, 247). |
Misalignment of the tube-part-IR relationship results in ____________________. | Shape distortion (Saia, Lange Q&A, pg. 203, 240). |
Using a short SID with a large field size is likely to ..... | Increase the anode heel effect (Saia, Lange Q&A, pg. 203, 240). |
By placing the patient in a ________ position it will reduce the production of scatter. | Prone (Saia, Lange Q&A, pg. 205, 242). |
The term windowing describes the practice of changing the image ____________ and/or ___________ scale. | Brightness, contrast (Saia, Lange Q&A, pg. 198, 235). |
Elongation and foreshortening are examples of _________ ____________. | Shape distortion (Saia, Lange Q&A, pg. 206, 243). |
________________ is the reduction of x-ray photon intensities as the photons pass through materials. | Attenuation (Saia, Lange Q&A, pg. 209, 248). |
Compared with a low-ratio grid, a high-ratio grid will absorb more ____________ and _____________ radiation. | Scattered, primary (Saia, Lange Q&A, pg. 200, 237). |
As the crystal size decrease in a ______ system, it will cause an increase in CR resolution. | PSP (Saia, Lange Q&A, pg. 201, 238). |
By using a _______ kV, you can compensate for the effect of very dissimilar tissue densities. | High (Saia, Lange Q&A, pg. 205, 242). |
_______ _________ is the absorption of useful radiation by a grid. | Grid cutoff (Saia, Lange Q&A, pg. 206, 243). |
Give 3 examples of appropriate methods of minimizing motion unsharpness. | Suspended respiration, short exposure time, and good patient instruction (Saia, Lange Q&A, pg. 198, 236). |
For the same FOV, spatial resolution will be improved by using a __________ matrix. | Larger (Saia, Lange Q&A, pg. 205, 242). |
Unopened boxes of radiographic film should be stored away from radiation and in the _________ position. | Vertical (Saia, Lange Q&A, pg. 199, 236). |
A 15% decrease in kV accompanied by a 50% increase in mAs will result in a ________ scale of contrast. | Shorter (Saia, Lange Q&A, pg. 207, 245). |
The direction of electron travel in the x-ray tube is ____________ to ___________. | Cathode, anode (Saia, Lange Q&A, pg. 205, 242). |
Pneumonia requires a ___________ in exposure factors. | Increase (Saia, Lange Q&A, pg. 207, 245). |
Focal spot blur is greatest toward the __________ end of the x-ray tube. | Cathode (Saia, Lange Q&A, pg. 207, 246). |
mAs is __________ related to patient dose. | Directly (Saia, Lange Q&A, pg. 207, 246). |
During CR imaging, the latent image present on the PSP is changed to a computerized image by the _______. | ADC (analog digital converter) (Saia, Lange Q&A, pg. 206, 244). |
Having a patient will congestive heart failure, an ___________ in exposure factors will be required. | Increase (Saia, Lange Q&A, pg. 201, 238). |
Diagnostic x-rays are generally associated with _________ frequency and ____________ wavelength. | High, short (Saia, Lange Q&A, pg. 210, 248). |
Grid interspace material is made of ______________ and _______ ______. | Aluminum, plastic fiber (Saia, Lange Q&A, pg. 196, 233). |
The technologist can reduce scatter by using the smallest possible ___________ ________. | Field size (Saia, Lange Q&A, pg. 205, 242). |
Using fixed mAs and a variable kV, each centimeter increase in patient thickness requires what kV adjustment? | Increase kV by 2 (Saia, Lange Q&A, pg. 199, 236). |
What is the component of a CR imaging plate that records the radiologic image? | Photostimulable phosphor (Saia, Lange Q&A, pg. 197, 234). |
Decreasing field size from 14X17 inches to 8X10 inches, with no other changes, will _____________ the amount of ___________ generated within the part. | Decrease, scatter (Saia, Lange Q&A, pg. 197, 234). |
The luminescent light emitted by the PSP is transformed into the image seen on the CRT by the ________. | ADC (analog digital converter) (Saia, Lange Q&A, pg. 197, 235). |
As the laser beam size decreases, the CR _______________ will increase. | Resolution (Saia, Lange Q&A, pg. 201, 238). |
Recorded detail is __________ related to SID. | Directly (Saia, Lange Q&A, pg. 196, 233). |