Grids Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Question | Answer |
are used to control scatter radiation | Grids |
tools to decrease scatter | The grid, lower kVp ,Decreasing the field size, Decreasing the body part thickness |
Grid was developed by | Gustav Bucky in 1913 |
When you use a grid you ______ the dose to the patient which will _______the mAs | increase increase |
The grid only allows x-rays through that are traveling in | straight lines |
Grids clean up | scatter radiation |
Grids consist of carefully fabricated sections of | radiopaque material (grid lines) alternating with sections of radiolucent material (interspace material) |
Grid ratio | height of the grid/width of the interspace material |
Moving grids aka | reciprocating aka oscillating grids |
clean up scatter radiation better | High ratio grids |
GRID FREQUENCY | Usually 60-110 lines per inch |
Grids with high frequency show | less distinct grid lines |
High frequency grids usually will also have | a higher grid ratio |
The grid lines are made of | lead |
The interspace material is made of | aluminum or plastic |
Both the front and back covers of the grid are usually made of | aluminum |
60-80 grid lines per inch will have to be | shaken |
Most grids have an improvement factor of between | 1.5 and 2.5 |
many shades of gray | low contrast |
black and white | high contrast |
CONTRAST IMPROVEMENT FACTOR | K = Radiographic contrast with a grid/ Radiographic contrast without a grid |
the amount of increase in radiographic technique needed because a Bucky is being used | BUCKY FACTOR |
As the Bucky factor increases | the radiographic technique and patient dose increases |
BUCKY FACTOR | = Patient dose with a grid/ Patient dose without a grid |
Parallel grid | all the lead strips are parallel to each other |
developed by Hollis Potter | Moving grid |
more difficult to manufacture than parallel grids but there is no grid cutoff | Focused grid |
this is the type used most | focused grid |
Grid Cut Off | the grid line absorb to much photons because of the distance of the tube it to far or to close and causes cut off on the film |
problems that cause grid cut off | Off level grid, Off center grid, Off focus grid ,Upside down grid |
is due to the grid being backwards and the film is very dark center and light sides | upside down grid |
AIR GAP TECHNIQUE | does not use a grid |
A gap between the body part and the film | AIR GAP TECHNIQUE |
Improves image contrast | Air Gap Technique |
Put grid lines crosswise and lengthwise | Crossed grid |