Chap 5 Flat-panel DR Test

Enter the letter for the matching Answer
incorrect
1.
EI does or does not represent an equivalent for patient dose entrance exposure?
incorrect
2.
Direct TFT: the photoconductor (a-Se) does what?
incorrect
3.
High frequencies contain _____, low frequencies contain ______.
incorrect
4.
Fill factor is expressed how?
incorrect
5.
Csi crystals (______ phosphor). Gradolinium oxysulfide (_____ phosphor).
incorrect
6.
x-ray attenuation depends on what 3 factors?
incorrect
7.
Indirect flat panel TFT detectors: following the x-ray scintillator (x-ray detection medium) is what?
incorrect
8.
(indirect flat panel (TFT) detectors) ______ crystals are deposited in a needle like fashion (_______ phosphor) and run in the direction of the x-ray beam.
incorrect
9.
Indirect TFT: the purpose of the a-Si photodiode layer is ?
incorrect
10.
You base scaling the histogram on what?
incorrect
11.
X-ray scintillators are what for indirect flat panel TFTs?
incorrect
12.
Fill factor affects what 2 things?
incorrect
13.
Systems that use phosphor (indirect detectors) and systems that use photoconductors (direct) differ by converting x-rays to electrical how?
incorrect
14.
Image lag is aka
incorrect
15.
Scintillator screen does what in CCD detectors? ****
incorrect
16.
4 main components of a CCD detector?
incorrect
17.
High MTF value at lower spatial frequencies means that the detector provides better _____.
incorrect
18.
2 types of indirect digital detectors?
incorrect
19.
What is exposure latitude?
incorrect
20.
3 tests to measure spatial resolution?
A.
an a-Si photodiode flat-panel layer
B.
spatial resolution and contrast resolution (detail and signal-to-noise)
C.
detects x-rays and converts them into light
D.
the exposure falling on the detector.
E.
cesium iodide (Csi) crystals are deposited in needle like fashion, (structured phosphors)
F.
x-ray absorber, scintillator, light optics, the CCD. (which is a sensor chip.. or many...)
G.
detects x-ray photons from the patient and converts them directly into electrical charges.
H.
examines the response of the image receptor to the radiation falling upon it.
I.
CsI and Gd2O2S (gradolinium)
J.
contrast resolution
K.
fine details, contrast.
L.
as a percentage. (Fill factor of 80% means that 20% of the pixel area is occupied by the detector electronics and 80% is sensing area)
M.
Csi- structured, Gradolinium- turbid
N.
charged coupling device (CCD) digital detector, and the flat-panel thin film transistor (TFT) digital detector. (difference between them is technical factors on how to convert light to electrical)
O.
memory effect
P.
atomic number (Z#), density, and thickness of attenuating material.
Q.
phosphor (indirect)- convert x-ray energy into electrical through an intermediate stage of light photons, photoconductors (direct) convert energy energy directly into electrical charge without the intermediate stage.
R.
bar test pattern, sharp-edged object, narrow slit.
S.
does not
T.
To convert th elight from the x-ray detection scintillator into electrical charges.
Type the Answer that corresponds to the displayed Question.
incorrect
21.
TFT stands for?
incorrect
22.
Direct TFT: the photoconductor is usually what substance?
incorrect
23.
Third step in image processing is ___________, where the adjusted or scaled raw data values are mapped to the "for presentation" values to display an optimum image.
incorrect
24.
the ability of the imaging system to resolve fine details present in an object is called
incorrect
25.
As the spatial frequencies increase, the DQE ______
incorrect
26.
A system that has a higher spatial frequency at an MTF of .1 will show _____ spatial resolution than a system with below MTF of .1.
incorrect
27.
Detectors with ____ fill factors (____ sensing areas) will provide better spatial and contrast resolution.
incorrect
28.
Image obtained initially from the detector is referred to as what?
incorrect
29.
Before the flat panel detector can be used, it must be prepared. This is referred to as __________.
Type the Question that corresponds to the displayed Answer.
incorrect
30.
During readout, system electronics provide systematic collection of changes on each chip in a manner referred to as a “bucket brigade”. (the charge pattern from the readout of pixels is sent to the ADC for digitization)

Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.