sprinkler practice test

        Help!  

Question
Answer
what is the minimum size of threaded rod required for sprinkler piping   3/8  
🗑
how often do fire department connections get hydrostatically tested   every 5 years  
🗑
sprinkler heads exposed to corrosive conditions are often covered with   wax  
🗑
automatic sprinkler system have ____________ caps on the fire department connections   green  
🗑
how often shall the stem of an OS&Y valve be lubricated   annually  
🗑
in a pressurized tank, the proper water to air radio is   2/3 water to 1/3 air  
🗑
sprinkler heads are factory tested at what PSI   400  
🗑
the 5 year dry pipe trip test is to be performed by   master fire suppression contractor  
🗑
inspection records are to be maintained on site by the building owner for   3 years  
🗑
(UL) underwriter's laboratory and factory mutual (FM) are two   testing agencies  
🗑
a quick response sprinkler head has a RTI of ______ or less   50  
🗑
a sprinkler system equipped with open heads is a _______ system   deluge  
🗑
the interior of a check valves are to be inspected every   quarterly  
🗑
the freezing point of antifreeze solution is tested with   hydrometer or refractometer  
🗑
local law 58/2009 requires standpipe and sprinkler rise piping to be painted   red  
🗑
water motor gongs are to be tested   quarterly  
🗑
fire department connections are to be inspected   quarterly  
🗑
the distance for the hanger assembly to the centerline of an upright sprinkler head shall be   no less than 3 inches  
🗑
in a water -spray fixed system inspection, the strainer is corroded, what color tag should be put on   yellow  
🗑
the automatic ball drip is located   between lower check valve and fire department connection  
🗑
a sprinkler head with a red frame has a temperature classification of   extra high  
🗑
the buildup of foreign material on a sprinkler head is called   loading  
🗑
the minimum air pressure inside a pressure tank is   75psi  
🗑
a gravity tank should be a least__________ feet above the highest line of a sprinkler heads that is supplies   25''  
🗑
the hydraulic name plate shall be inspected   quarterly  
🗑
preaction and deluge valve are to be tested   annually  
🗑
what color tag is required when sprinkler heads are found to be lightly corroded   orange  
🗑
gauges are to be replaced every   5 years  
🗑
what color tag is required when the circuit breakers on a special service pump are over two years old   orange  
🗑
obstruction in sprinkler system shall be tested every   5 years  
🗑
12 spare sprinkler heads are required when there are   301-1,000 heads  
🗑
all sprinkler heads manufactured prior to __________ shall be replace   1920  
🗑
house pumps fill the gravity tank at gpm rate of   65  
🗑
4 feet below the deflector the spray pattern of a sprinkler is   15' diameter at 15gpm  
🗑
FDNY must be notified for an out of service condition if   system will not return to service for more than 8 hours  
🗑
a sketch of the compactor system shall be drawn by   s-12 Cof F holder  
🗑
what tag is required when sprinkler heads made prior to 1920 have not been replaced   orange  
🗑
during an operational test of a foam-water sprinkler system the nozzle are plugged. what color tag is required   red  
🗑
steel water storage tank without corrosive protection are to be inspected every   3 years  
🗑
five, six, and eight inch pipe requires what size threaded rod   1/2  
🗑
a preaction valve prevents __________ from entering the system   water  
🗑
a sprinkler head with a white frame has a temperature rating of   175-225 °f  
🗑
a sprinkler head that has been recalled is   cycling  
🗑
the weekly test of an electric fire pump is   10 min  
🗑
upon inspection of a sprinkler system the hydraulic nameplate was missing. what color tag is required   yellow  
🗑
the temperature classification of a sprinkler head with a blue bulb is   high  
🗑
fire department connection shall be free of obstructions a minimum of   3 feet in each direction  
🗑
when inspecting a peaction system the electrical components are not in service. what color tag is required   red  
🗑
the temperature inside the fire pump room is maintained above ______ ° degrees f   40  
🗑
vane type water flow devices shall be tested   semi-annually  
🗑
spare sprinkler head/wrench shall be inspected __________ for the proper number of head and wrench   annually  
🗑
when inspecting a sprinkler system, the spare sprinkler head cabinet is missing. what color tag is required   yellow  
🗑
on dry type sprinkler heads no test conducted for 12 years, what color tag is required   yellow  
🗑
non-automatic sprinkler system have _________ caps on the fire department connection   silver  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: jigger