Meter questions

Quiz yourself by thinking what should be in each of the black spaces below before clicking on it to display the answer.
        Help!  

Question
Answer
What is the calibration gas for the PID in this meter?   Isobutylene  
🗑
How long is the typical warm up time for this meter?   3-4.5 minutes  
🗑
What is the maximum feet of tubing the pump is rated to pull a sample through?   150 feet of tubing  
🗑
How long will the typical battery last in operation?   14 hours  
🗑
For PID detection, what are the ranges?   0-2000 ppm  
🗑
For PID detection, what is the low alarm?   100 ppm  
🗑
For PID detection, what is the high alarm?   200 ppm  
🗑
What is the power of the PID lamp?   10.6 eV  
🗑
For EXplosive detection, what is the low alarm?   10%  
🗑
For EXplosive detection, what is the high alarm?   20%  
🗑
What is the range for the oxygen sensor?   0-25%  
🗑
What is the low and high alarm levels for oxygen?   19.5 - 23.5%  
🗑
What is the range for the CO sensor?   0-2000 ppm  
🗑
What are the low and high ACTION LEVELS for CO?   10 for low and 100 for the high  
🗑
What are the low and high ALARM LEVELS for the CO?   30 ppm and 60 ppm  
🗑
What is the range for the H2S sensor?   0-100 ppm  
🗑
What is the low alarm for the H2S sensor?   10 ppm  
🗑
What is the high alarm for the H2S sensor?   20 ppm  
🗑
How long is the startup sequence for the XAM7000?   3.5 to 4.5 minutes  
🗑
Is the fresh air setup for the XAM7000?   No, unless the meter notes a sensor drift  
🗑
What does the up arrow do when the meter is off?   It will display info including the battery status  
🗑
What is the hose made of?   Polyurethane  
🗑
How do you use the meter in Diffusion Mode   Remove back plate where the magnets are held, thats what engages the pump mode  
🗑
How long does it take Air to move through 3 ft of hose?   1 second  
🗑
What does an " ! " mean on the display screen?   Indicates a message or notice  
🗑
What does a " X " mean on the display screen?   Indicates there is an error or fault with a meter funciton  
🗑
What does 4 "up arrows" in a row mean on the display screen?   The Gas is above the Max Range for the sensor  
🗑
What does "- - - - " mean on the display screen?   Flow alarm while in pump mode /Pumps not drawing enough air  
🗑
On the Red Strap, what is the high capacity O2 range?   0 - 100%  
🗑
What can cause faulty readings for O2 sensors?   High Humidity and High / Low Altitudes  
🗑
What is the range for the CO sensor on the Red Strap?   0 - 10,000 PPM  
🗑
What is the range for H2S sensor on the Red Strap?   0 - 1,000 PPM  
🗑
What is the main benefit for using IR (infrared) Sensors?   IR sensors work in O2 deficient atmospheres  
🗑
What is a downfall for using IR Sensors   IR sensors cannot see gases that are lighter than air, such as Acetylene and Hydrogen  
🗑
What Gas is the LEL Sensor calibrated to?   Methane  
🗑
What is the High CO2 Sensor's range and alarm levels on the Red Strap?   (0 - 100%) Low 1%; High 3%  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: yakshave
Popular Chemistry sets