click below
click below
Normal Size Small Size show me how
Scatter Control 177
Part 1
| Question | Answer |
|---|---|
| As kVp Increases penetration, Total Interactions ________ | Decrease |
| higher kVp means there are _________ | Less Interactions |
| Of those interactions that do occur with a higher kVp, more are ______ | Compton |
| Scatter radiation decreases ________ | Radiographic Contrast |
| Less ______ = Less Scatter | Matter |
| Radiographic Grids Improve the image quality by absorbing scatter radiation that ______ the patient, reducing the amount of scatter that reaches the image receptor | Exit |
| ________ DO NOT protect the patient | Radiographic Grids |
| Increasing collimation means _______ | Decreasing Field Size |
| Decreasing collimation means _________ | Increasing Field Size |
| Types of Beam Restricting Devices: Aperture Diaphragms | Simplest type A flat piece of lead (diaphragm) that has a hole (aperture) in it Placed directly below the x-ray tube window |
| Types of Beam Restricting Devices: Cones and Cylinders | An aperture diaphragm with a cone or cylinder extension (flange) attached to it |
| Types of Beam Restricting Devices: Collimators | Equipped with: A white light source and a mirror to project a light field onto the patient An x-ray field measurement guide in case of light failure A plastic template with crosshairs |
| Both Cones and Cylinders limit unsharpness surrounding the image, but ________ is better | Cylinder |
| A ______ Adjusts the primary beam size and shape to the size of the IR | Positive Beam-Limiting Device |
| Tech's using Automatic Collimators (PBL) cannot increase primary beam to go outside the IR ________ | Unless there is an Override Mechanism |
| Radiographic Grids are Devices that have very thin lead strips with _________ | Radiolucent Interspaces (usually aluminum) |
| Radiographic Grids are Placed_______ the patient and IR | Between |
| Using a Radiographic Grid Creates images with improved______ | Contrast |
| Scatter is ______, therefore it's absorbed by lead strips | Angled |
| __________ is the number of lead lines per unit length EX: 40 lines per cm | Frequency |
| _______ is the height of lead strip ÷ width of interspace EX: height = 3.2 mm, interspace width = 0.2mm | Ratio |
| Higher grid ratio = _______ | More Scatter Absorbed |
| _________ are the preferred type of linear grid used by technologists | Focused Grids |
| _______: lead lines run in only one direction Parallel Focused | Linear Grids |
| ______: lead lines run at right angles to one another | Cross-Hatched Grids |
| Parallel Grids are always ______ | Non-Focused |
| _______ lines are perpendicular to the long axis | Short Dimension |
| _________ lines are parallel to the long axis | Long Dimension |
| _______ Can also be short dimension or long dimension | Focused Grids |
| A smaller area needs more______ | mAs |
| Increasing Collimation will _______ Quantum Noise | increase (without an appropriate increase in mAs) |
| Increasing Field Size will_______ Quantum Noise | Decrease |