| Question | Answer |
|---|---|
| After some decades of experience with modern digital x-ray equipment and as a result of improvements in dosimetry estimates of the efficacy of shielding with modern equipment and techniques, professional and scientific societies are | modifying shielding practices in diagnostic radiology to discourage the use of patient gonadal shielding and fetal shielding |
| According to the American College of Radiology (ACR), abdominal radiologic examinations that have been requested after full consideration of the clinical status of a patient, including the possibility of pregnancy, need | not be postponed or selectively scheduled. |
| During a radiographic examination, which of the following combinations of technical exposure factors reduce patient radiation dose? | higher kVp, lower mAs |
| Studies of groups such as the atomic bomb survivors of Hiroshima have shown that damage to the newborn is unlikely for doses below | 0.2 Gy |
| ________________________ are the sensing devices most often used to measure skin dose directly. | thermoluminescent dosimeters |
| Which of the following procedures results in the lowest radiation effective dose to the patient? | Dual energy X-ray absorptiometry |
| In the event that a pregnant patient is inadvertently irradiated | the radiation safety officer or the medical physicist should perform the calculations necessary to determine fetal dose. |
| Which of the following is frequently a problem in diagnostic pediatric radiography? | patient motion |
| Essentially all diagnostic medical procedures result in fetal exposures ______________, so that _______________________. | of less than 0.01 Gy; the risk of abnormality is very small |
| Reducing the field size to the anatomic features of interest not only reduces patient exposure but also | increases completed image quality by decreasing scatter |
| According to the U.S. Public Health Service, the genetically significant dose (GSD) for the population of the United States is approximately | 0.20 msv |
| Because multiple bony areas span the entire body, the radiation dose absorbed by the organ called bone marrow | cannot be measured by a direct method; it can only be estimated. |
| A blotchy radiographic image that results when an insufficient quantity of x-ray photons reaches the image receptor is called | quantum noise or mottle |
| When a properly calibrated automatic exposure control (AEC) is not employed to obtain a uniform selection of technical x-ray exposure factors, well-managed imaging departments? | make use of standardized technique charts |
| Which of the following must always be the first step in protection of the reproductive organs? | Adequate and precise collimation of the radiographic beam to include only the anatomy of interest |