click below
click below
Normal Size Small Size show me how
Facility design ch23
Facility design notes based off ch 23 from textbook
| Term | Definition |
|---|---|
| predesign phase | needs analysis, feasibility study, forming a master plan, and hiring an architect |
| design phase | the committee's ideas come together with regard to the facility's structure and design elements |
| construction phase | the period of time from the beginning of construction to the end |
| preoperative phase | finishing interior decor, hiring staff, planning for staff development, planning to open the facility, and planning for organization of administrative and clerical duties |
| location of s&c facility should be | generally on the ground floor away from offices and classrooms |
| supervision location | should be in a central location in the facility with clear line of sight and mirrors providing the opportunity to look out and see everyone |
| how much Is the height for a ramp or wheelchair lift? | 0.5 inches (1.3cm) |
| how long should a ramp be? | 12 inches for every 1-inch rise (30.5 cm run for every 2.5 cm rise) |
| steps should have | a rough strip on the edge to prevent people from falling |
| Ceiling Height | 12-14 feet (2.66 m - 4.27 m), enough clearance to allow people to perform jumping or explosive activities |
| most common flooring | rubber flooring, anti fugal carpet and indoor turf |
| how much lumens should be in the lights? | between 50 and 100 lumens |
| what type of lighting should be include | artificial and natural light |
| what temperature should the facility be | between 68-78 Fahrenheit |
| relative humidity should not | exceed 60% |
| how many inches should the mirrors be above the floor? | 20 inches (50 cm) |
| how much inches should the mirrors be away from the equipment | at least 6 inches (15 cm) |
| barbells and dumbbells should have a minimum of _____ of space between them to allow for movements between racks | 36 inches (91 cm) |
| ________ and ____________ are the top priorities when deciding placement of equipment | safety, function |
| stretching and warm up areas should have at least _______ of open space | 49 square feet (4.6 m^2) |
| circuit training training machine should be placed at _____ and ______ apart | 24 inches (60 cm) and 36 inches (90 cm) |
| how many inches should there be between the ends of racked bars | 36 inches (90 cm) |
| racks and platforms should have ________ of walk space between them | 3 to 4 feet (0.9-1.2 m) |
| circuit training area walkway should be | between 4-7 inches (1.2-2.1 m) wide |
| space needed for bikes | 24 ft^2 (2.2m^2) |
| space needed for stair steppers | 24 ft^2 (2.2m^2) |
| space needed for skiers | 6ft^2 (0.6m^2) |
| space needed for rowers | 40ft^2 (3.7m^2) |
| space needed for treadmills | 45ft^2 (4.2m^2) |
| there should be a checklist for | cleaning |
| mission statement | an organization's statement of purpose |
| program goals | the desired end products of a strength and conditioning program |
| coach centric | a directive approach where the coach is dictating what needs to be done, how to do it, and when |
| program objectives | specific means of attaining program goals |