click below
click below
Normal Size Small Size show me how
ESWS
LPD ESWS Study
| Question | Answer |
|---|---|
| What are the six categories of hazardous material? | (FAT COC) Flammable, Aerosol, Toxic Corrosive, Oxidizing, Compressed Gasses |
| How many shore power cables do we have? | 16: 8 PORT and 8 STBD |
| How many MPDEs does the ship have? | 4 |
| Where are 1A and 1B MPDE located? | Main 1 |
| Where are 2A and 2B MPDE located? | Main 2 |
| What is the total capacity of the Lube Oil Sump? | 2290 Gallons |
| What is the operating level of the Lube Oil Sump with the engines stopped? | 2000 Gallons |
| What is the operating level of the Lube Oil Sump with the engines running? | 1900 Gallons |
| When will the low level alarm go off for the Lube Oil Sump? | 1375 Gallons |
| How much does the anchor weigh? | 27550 Pounds |
| How many repair lockers do we have? | 6 + DCUPS 41 and 21 and the RNA locker |
| How many AFFF Stations are there? | 7 |
| What is an SCBA charged to? | 4500 PSI |
| What are the 5 steps to ORMMM? | - Identify Hazards - Assess Risks - Make risk decisions - Implement safety controls - Supervise |
| What are the 5 classifications of fires? | Alpha, bravo, Charlie, delta and sierra |
| In what 3 ways is heat transferred? | Radiation, convection and conduction |
| MCPON | |
| SECNAV | |
| CNO | |
| President | Donald Trump |
| Vice President | |
| What is line 1 3/4 or smaller? | Small stuff |
| How many A/Cs do we have onboard? | 5 |
| What is the emergency ahead pitch percentage? | 120% |
| How many lube oil service pumps are there? | 8- 2 per engine |
| What is the lube oil service pump rated at? | 640 GPM |
| How many lube oil purifiers are there? | 4- 2 located in each main space |
| What are the jacket water cooling pumps rated at? | 1255 GPM |
| What are the central fresh water cooling pumps rated at? | 2610 GPM |
| What are the seawater cooling pumps rated at? | 1350 GPM |
| How many potable water tanks are there? | 6- 3 in main 1 and 3 in main 2 |
| What is the capacity of the potable water tanks? | 62877 Gallons |
| How many potable water pumps are there? | 4- 2 in each main space |
| How many LPACs are there? | 3- 1 and 2 in aux 2, 3 in aux 3 |
| What are the LPACs rated at? | 125 PSI |
| How many MPACs are there? | 2- 1 in each main space |
| What are the MPACs rated at? | 450 PSI |
| What is important about the MPACs? | They provide the staring air for the MPDEs and SSDGs |
| What does degaussing do? | Neutralize the ship's magnetic field |
| What is deperming used for? | To neutralize ship's permanent magnetic signature |
| How many reefers are there? | 2- ACMR |
| What types of AC/R do we have? | 200 ton york centrifical |
| How many deballast air compressors are there? | 3- 2 in deballast air compressor room 2, 1 in deballast air compressor room 1 |
| How many MOPP levels are there? | 5 |
| How many CPS zones are there? | 4 |
| How many decon stations are there? | 4- FWD of CCS, by repair 4, boat valley, medical |
| What is the P-100 lubricated with? | 2190 oil |
| What is the normal operation of the P-100? | 100 GPM at 83 PSI with 22' suction lift |
| What model is the EEBD? | Ocenco M20.2 |
| How many conflag stations are there? | 6- main v, lower v fwd, upper v, lower v aft, well deck and helo control station |
| How many watermist pump rooms are there? | 2- 1 fwd, 2 aft |
| What are the watermist pumps rated at? | 230 GPM at 1200 PSI |
| How long is the watermist discharge delay? | 15 seconds |
| At what temperature do the wet sprinklers go off? | 175 degrees |
| At what temperature do the dry sprinklers go off at? | 160 degrees |
| Where does the dry sprinkling system provide protection? | Flammable gas cylinder storeroom, fwd and aft mast and magazines |
| What is the firemain system configuration? | 10" vertical offset loop |
| How many firepumps are there? | 10 |
| Where are the firepumps located? | 1- FWD VCHT 2,3- Aux 1 4,5- Main 1 6,7- Aux 2 8- Main 2 9,10- Aux 3 |
| What are the fireumps rated at? | 1000 GPM at 175 PSI |
| What does VCHT stand for? | Vacuum, collection, holding and transfer |
| What is sewage? | Black water: human waste |
| What is plumbing waste? | Grey water: sinks, showers, laundry, galley |
| How many VCHT pump rooms are there? | 2- 1 fwd, 1 aft |
| How many gallons does the FWD VCHT holding tank hold? | 4095 Gallons |
| How many gallons does the FWD VCHT plumbing drain tank hold? | 7502 Gallons |
| How many gallons does the AFT VCHT holding tank hold? | 6842 Gallons |
| How many gallons does the AFT VCHT plumbing drain tank hold? | 12495 Gallons |
| How many sewage discharge pumps are there? | 4, non-clog discharge pumps (eddy pumps) |
| What are the sewage discharge pumps rated at? | 100 GPM |
| How many ejector assemblies are there? | 6 |
| What is the capacity of the AFFF reserve and transfer tank? | 2115 Gallons |
| What is the capacity of the AFFF station tanks? | 1295 Gallons |
| How may types of drainage do we have and what are they? | 3- main, secondary and special |