Ch 6 FireFighter PPE
Inspection and Maintenance of SCBA
| Question | Answer |
|---|---|
| NFPA 1852 | establishes the frequency of SCBA inspections |
| You must clean and inspect your SCBA | after each use, at the start of every duty shift, every week, report repairs immediately and take unit out of service |
| Inspect following SCBA components | Facepiece, Backpack and harness, breathing air cylinder, Hoses, low pressure alarm, Regulator, pressure indicator gauges, PASS, Check hydrostatic testing date label |
| Wash facepiece with | warm water contains a mild disinfectant and then rinse with clear, warm water, dry facepiece with lint free cloth or air dry do not use paper towels, ensure proper operation of the exhalation valve |
| Common damage of facepiece include | Cracked, broken, or over stretched straps, cracks or tears in the face seal, Bent or deformed buckles, scratches, blistering and cracks in lens |
| SCBA Inspection and Maintenance should be done | Annual, specially trained factor qualified technicians, documentated in SCBA maintenance log |
| Stationary fill systems | Systems installed at stations |
| Mobile fill Stations | Systems mounted on apparatus or trailers |
| Each source must provide | Type 1 D quality air |
| When refilling a SCBA cylinder | Check hydrostatic test date, perform inspection, check working pressure, wear hearing and eye protection, Place in shielded fill station, fill slowly, ensure completely full but not over pressurized, allow only trained personnel to operate |
| Follow criteria must be met before filling a worn SCBA | NIOSH approved RIC UAC fill option, A risk assessment has been conducted to limit safety hazards, imminent threat to the safety of the downed firefighter |
| Stationary Fill Stations | contract process out to a qualified breathing air supplier, third party testing facility must regularly test breathing air |
| Required to exchange the breathing air cylinder under the following circumstances | Daily and weekly inspection if cylinder contains less than 90%, Training exercise, long duration emergency operations, after emergency operations |
| Protect respiratory equipment from | contamination, temperature changes, ultraviolet light, storage depends on size, available apparatus storage compartments and manufactures instructions |