Save
Upgrade to remove ads
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

Review Quiz 11

QuestionAnswer
The first step to inspect the insulation of a laparoscopic instrument is to Check the collar at the distal tip
Which of the following steps happens first when processing flexible endosocpes? Leak testing
Pneumatic cords are a cleaning concern because: They are dark in color, so soil is difficult to see
The purpose of using a decontamination battery or hose when cleaning powered surgical instruments is to: Keep fluid from entering the unit
One of the main reasons or powered surgical instrument repair is: Lack of preventative maintenance (PM)
Powered surgical instrument attachments: Can be peel packaged for sterilization if approved by the manufacturer
Loaned instruments should: Be decontaminated before use
Information regarding cleaning processes for endoscopes should be provided by the: Instrument manufacturer
Which of the following statements about endoscopes is true? Flexible endoscopes are time-consuming to clean
Electronic testing of laparoscopic insulation should be done: In the clean assembly area prior to set assembly
Pneumatic hoses: Should be pressurized for proper inspection
Powered surgical instrument batteries should be charged per the manufacturers’ instructions for use (IFU): Before sterilization
Semi-rigid endoscopes: Are used during urological procedures
Endoscopic cameras: Should be inspected for cuts, nicks or other damage to the cable
Robotic instruments: Are processed in the same manner as laparoscopic instruments
Created by: Fendi14
 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards