click below
click below
Normal Size Small Size show me how
17. Fire Protection
| Question | Answer |
|---|---|
| If a fire extinguisher cartridge is removed from a discharge valve, it should be? | used only on the original discharge valve assembly. |
| Smoke detectors that use a measurement of light transmissibility in the air are called | photoelectrical devices. |
| What occurs when a visual smoke detector is activated? | A lamp within the indicator illuminates automatically. |
| The thermal switches of a bimetallic thermal-switch type fire-detection (single-loop) system are heat-sensitive units that complete circuits at a certain temperature. They are connected in | parallel with each other, but in series with the indicator lights. |
| (Refer to Figure 21.) Determine what pressure is acceptable for a fire extinguisher when the surrounding area temperature is 33°F. (Rounded to the nearest whole number.) | 215 to 302 psig. |
| On a periodic check of fire extinguisher containers, the pressure was not between minimum and maximum limits. What procedure should be followed? | Replace the extinguisher container. |
| The types of fire-extinguishing agents for aircraft interior fires are | water, carbon dioxide, dry chemical, and halogenated hydrocarbons. |
| A carbon dioxide (CO(2)) hand-held fire extinguisher may be used on an electrical fire if the | horn is nonmetallic. |
| Built-in aircraft fire-extinguishing systems are ordinarily charged with | halogenated hydrocarbons and nitrogen |
| Why does the Fenwal fire-detection system use spot detectors wired parallel between two separate circuits? | A short may exist in either circuit without causing a false fire warning. |
| n some fire-extinguishing systems, evidence that the system has been intentionally discharged is indicated by the absence of a | yellow disk on the side of the fuselage. |
| A fire extinguisher container can be checked to determine its charge by | weighing the container and its contents. |
| A thermocouple in a fire-detection system causes the warning system to operate because | it generates a small current when heated. |
| Light refraction smoke detectors are activated when the detector | senses light reflected from smoke particles passing through a chamber. |
| The proper fire-extinguishing agent to use on an aircraft brake fire is | dry powder chemical. |
| Which fire-extinguishing agent is considered to be the least toxic? | Bromotrifluoromethane (Halon 1301). |
| When air samples contain carbon monoxide, portable carbon monoxide detectors containing yellow silica gel will turn which color? | Green. |
| Which fire-detection system measures temperature rise compared to a reference temperature? | Thermocouple. |
| Refer to Figure 21.) Using the chart, determine the temperature range for a fire-extinguishing agent storage container with a pressure of 330 psig. (Consider 330 psig for both minimum and maximum pressure.) | 45 to 73°F. |
| The thermocouple fire-warning system is activated by a | rate-of-temperature rise. |
| Smoke in the cargo and/or baggage compartment of an aircraft is commonly detected by which instrument? | Photoelectric cell. |
| Which of the following are fire precautions which must be observed when working on an oxygen system? | Display 'No Smoking' placards, provide adequate fire-fighting equipment, keep all tools and oxygen servicing equipment free from oil or grease, and avoid checking aircraft radio or electrical systems. |
| When used in fire-detection systems having a single indicator light, thermal switches are wired in | parallel with each other and in series with the light. |
| Maintenance of fire-detection systems includes the | replacement of damaged sensing elements. |
| A squib, as used in a fire-protection system, is a | device for causing the fire-extinguishing agent to be released. |
| The most common cause of false fire warnings in continuous-loop fire-detection systems is | dents, kinks, or crushed sensor sections. |
| What method is used to detect the thermal discharge of a built-in fire-extinguisher system? | A rupture of the red plastic disk in the thermal discharge line. |
| What is the color code for fire extinguisher lines? | Brown |
| A contaminated carbon monoxide portable test unit may be returned to service by | removing the indicating element and installing a new indicating element. |
| In what areas of aircraft would you find a carbon monoxide detector? | Cabin and cockpit. |
| Smoke detection instruments are classified by their method of | detection |