Save
Upgrade to remove ads
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

Backflow Test

QuestionAnswer
In accordance with title 17, reports of testing maintenence of backflow devices must be maintained: A. By the owner of the assembly B. For three years by the health agency C. By the tester D. By the Watee Agency for 3 years C. By the tester
When testinf a backflow, the number 2 shutoff must be closed first to: A. Maintain water pressure in the down stream piping B. Prevent backpressure during thentesting of the assembly C. Prevent Backsiphonage during the testing of the assembly D. Prevent C. Prevent back siphonage during the testing of the assembly
Backsiphonage due to an aspirator effect may be caused by: A. A sudden increase in the supply pressure. B. High velocity of flow through a pipe ter C. Water from a high pressured pump against the 2 check of an rp backflow D. A hose attatched to a hosebib B. High velocity flow of water through a Tee
A rp relief valve sense water pressure at 2 spots. One of which is the: A. Outlet of the number 4 testcock B. Outlet of the number 2 check valve C. Inlet of the number 1 check valve D. Atmospheric vent C. Inlet of the number 1 check valve
Backpressure from a low inlet to a plating tank containing toxic solution is properly prevented by: A. A pressure vacuun breaker B. A rp assembly C. An atmospheric vacuum breaker D. A double check valve B. Rp Assembly
During the test of a rp, the test gauge always reports the differential pressure accross A. Check 1 B. Check 2 C. The entire assembly D. The relief valve A. Check 1
How do you compensate for water continuously running through air vent on PVB? A.Open and close 1 line valve B. Open and close 2 line valve C. Open test cock 1 slowly D. You cannot continue A. Open and clock 1 line valve
When a perfect vaccum at sea level draws water up into a 40 foot pip the pressure in the piep above the water surface is? A. O psi B. 33.9 feet of water C. 14.7 psi D. 29.92 inches of mercury A. O psi
In accordance with title 17, backflow testerd must demonstrate compency in testing to: A. Local health department B. Water supplier or health agency C. American Backflow Prevention Association D. University of California B. Water supplier or health agency
Static pressure is defined as: A. Standing water in an open resevoir B. The weight of a vertical column of water against a closed valve C. The force exerted on a valve face by water flowing through a valve D. The force per unit area exerted by a column of D. The force per unit area exerted by a column lf water against a closed valve.
In accordance with tile 17 maximum clearance above grade for an RP is: A. 36 in B. 42 in C. 12 in D. 24 in A. 36 inches
The basic operating theory of an RP assembly is: A. The principle that water cannot be pressurized B. The water will not flow from a lower pressure to a higher pressure C. By reducing line pressure it automatically helps prevent backflow. D. The 1st check B. the water will not flow from a lower pressure to a higher pressure
There is a continuous discharge from the relief valve of an RP and the drop across number one check is 9.0 PSID, what is the most likely malfunction. A. 1 check valve failed B. Line pressure fluctuating C. Second check fouled D. Fouled relief valve D. Fouled relief valve
When compensating for a leaky number one shut off valve on a PVB, how do you know you have reach proper compensation? A. When water stops running out of the number 2 test cock B. When there is a slight drip at test cock number 2 C. When the gauge drops a B. When there is a slight drop at test cock number 2
A dual check valve is not: A. Approved B. Inline testable C. Repairable D. Replaceable B. Inline testable
The air inlet valve of an atmospheric vacuum breaker is fully open when the valves water pressure reached ____ psig A. -1 (6.9) B. 0 (0) C. 1 (6.9) D. 1.1 (7.6) B. 0
A pressure vacuum breaker is not permitted for use with: A. back siphonage B. contaminants C. elevated Downstream piping D. pollutants C. Elevated Downstream piping
SVP is not installed in areas that contain: A. check valves Downstream B. hazardous chemicals C. other vacuum breakers D. toxic fumes B. Hazardous chemicals
The minimum number of resilient seated valves on an SVB is: A. 2 B. 3 C. 4 D. 5 A. 2
An RP relief valve discharge after closing shut off number to is an indication of a fouled: A. Check 1 B. Check 2 C. Relief valve D. Shut off 2 A. Check valve 1
When you are flushing the test Cox prior to testing A reduced pressure principle backflow assembly you should always: A. Exercise the relief valve vigorously to make sure it opens correctly B. Slowly open the number to test cock until the relief valve ope C. Slowly open the number to test cock being careful not to open the relief valve
The number one test cock of a pressure type vacuum breaker assembly is located at the: A. Inlet of shut off valve number 1 B. Outlet of shut off valve number 1 C. Outlet of check valve number one D. Inlet of shut off valve number 2 B. Outlet shut off valve number 1
Hey atmospheric type vacuum breakers check valve closing pressure is ____ psig: A. 0 B. 1 (6.9) C. 2 (14) D. 3 (21) A. 0
A characteristic of the SVP operation is that the air inlet must seal before the: A. Air admittance valve opens B. Check valve closes C. Check valve opens D. Downstream uses open B. Check valve opens
Hey duplex Gage has ____ hoses. A. 1 B. 2 C. 3 D. 4 B. 2
The maximum level of protection provided by A reduced pressure principle assembly is: A. health hazard B. low Hazard C. pollution Hazard S. system hazard A. Health hazard
A line pressure gauge reading at test cock for on an RP will be approximately. A. 1 psi less than actual line pressure B. 5 PSI less than actual line pressure C. Six or more PSI less than actual line pressure D. 6 PSI greater than actual line pressure C. Six or more PSI less than actual line pressure
The US EPAs total coliform rule contains requirements for: A. Awrobic bacteria monitoring B. Cross connection surveys C. Plumbing code compliance D. State compliance schedules C. Plumbing code compliance
A fluid velocity increase results in an: A. Decreased flow area B. Increased flow area C. Increase in pressure D. Reduction in pressure D. Reduction in pressure
A pump discharge generating 43 PSIg (297 kpa) will result in a water column height of: A. 10ft B. 34 ft C. 85 ft D. 100ft D. 100 ft
The critical installation level for a water closet ball cock is ____ inches A. 1in B. 2in C. 3in D. 6in A. 1in
Atmospheric vacuum breaker is not permitted for use with: A. back siphonage B. contaminants C. continuous pressure D. pollutants C. Continuous pressure
A spill resistant vacuum breaker is protection for: A. Containment back pressure B. Containment back siphonage C. Isolation back pressure D. Isolation back siphonage D. Isolation back siphonage
The application of a double check valve assembly is based on: A. Contamination toxicity B. daily water use C. degree of Hazard D. plumbing system pressure D. Plumbing system pressure
Backflow prevention assembly sha'll be tested: A. Annually B. upon installation C. after repair service D. all of the above D. All the Above
Design pressure of an RP is created by: A. the relief valve spring B. the number to check valve C. closing the number to shut off d. the spring on the number one check valve D. The spring on the number one check valve
During a field test of a RP assembly 2nd check valves failure is indicated by: A. An increase in the differential pressure reading a decrease in B. diferential pressure reading with relief valve discharge C. no change in diferential pressure reading D. di B. A decrease in diferential pressure reading with relief valve discharge
During a field test of a RP assembly a momentary Drift from relief valve while testing the number to check indicates. A. Number one check failing B. number 2 check failing C. number 2 disc compression D. failing relief valve B. Number two check failing
When testing check valve number one of a double check if the water continues to flow out of the test cock number three and most probable cause is: A. Lincoln number to Check B. Number two shut off valve leak C. number two check valve leak D. number one D. Number one shut off valve leak
After bleeding the test cocks on a pressure vacuum breaker the hoses connected to: A. Number 1 Test cock and low side B. number 1 Test cock and high side C. number two test cock and low side D. number two test cock and high side D. Number two test cock and high side
In testing the RP the number one test cock is used for: A. A test when the assembly is experience severe water hammer B.flushing the unit of air when the assembly is subject to winterization C.connecting to number for test cock if the relief valve rating C. Connecting to number for test cock if the relief valve reading cannot be reduced to open the relief
Well testing SVP the check valve water continues to run from the bleed screw which of the following is true: A. Number two line valve is leaking B. number one line valve is leaking C. check valve is leaking D. who in the world knows B. Number one line valve is leaking
Identify the primary factor which contributes to the reversal of flow of water in Pipelines: A. gradience of pipeline B.distance to point of use from the reservoir or pump C. high velocity of flow D. back siphonage D. Back siphonage
During a field test of a reduced principle assembly II check valves failures indicated by A. an increase in the differential pressure reading B. a decrease in diferential pressure reading with relief valve discharge C. no change in the differential press B. A decrease in the diferential pressure reading with relief valve discharge
You have completed testing the number one check valve on a double check valve assembly he used to bleed valve arrangement to acquire of valve of .7 PSI across number one check valve you may proceed in the following manner: B. Fail Number one check valve a B. Fail the number one check valve and the assembly repairs the number one check valve must be made prior to continuing the test
A fire sprinkler system containing black iron pipe should be protected with a minimum of A. double check B. atmospheric vacuum breaker C. air gap D. pressure vacuum breaker A. Double check
Nsbb is not installed in areas that contain A. check valves Downstream B. hazardous chemicals C. Othervacuum breakers D. toxic fumes B. Hazardous chemicals
Hey water column elevation of 83 inches is approximately blank PSI A. 1 B. 2 C. 3 D. 4 B. 2
When testing the air Inlet of a pressure vacuum breaker you have opened the high side control needle valve one quarter turn the indicated diferential pressure is 0 but the air and let has not opened what does this indicate: A. There's back pressure to the B. The air Inlet is leaking
When testing me number one check valve of a double check valve assembly you have opened the number 3 test cock to atmospheric the water recedes from the site to how do you proceed: C. Lower the casket to the center line of the assembly record the reading Lower the test kit to the center line of the assembly record the reading as a static pressure drop across check valve number one note that the number two check valve and the number two shut off valve are leaking and terminate the test
What a perfect vacuum at sea level draws water up into a 40 foot pipe the pressure in the pipe above the water surface is: A. 0 B. 33.9 feet of water C. 14.7 psia D. 29.92 inches of mercury A. 0
The establishment of a list of acceptable backflow prevention assembly for the service protection of the water supply system as the responsibility of the A. local Health Department B. the Environmental Protection Agency C. the water purveyor D.the dep B. The Environmental Protection Agency
Created by: Standjmcstrong
 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards