Save
Upgrade to remove ads
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

cco site considerati

cco site considerations

QuestionAnswer
What should be of major concern when considering the supporting surfaces for crane set-up locations? voids, tanks, loose fills, depressions
What effect does span blocking have on outrigger floats/pads? decreases strength
If working near power lines and using a tagline, which type of rope is least conductive to electricity? polypropylene
When working on a site with nearby power lines you must: -avoid stockpile material under power lines -maintain the correct distance according to the rated K.V. -avoid lifting loads over power lines
According to OSHA 1926. 1411, while traveling a crane under power lines, if any part of the equipment will get closer then 20 feet to the lines you must: use a dedicated spotter
Which is the most common cause of injuries to the crane operators? falls from the crane getting on and off
What is the preferred type of outrigger pad support? hardwood timber mats
According to OSHA 1926. 1409 for power lines rated over 350 kv up to 1000 kv, but the exact voltage is not known, what is the minimum clearance between the lines an any part of the crane or load? 50ft
If an operator is working in a new construction area, confirmation of the ground conditions and it's ability to support anticipated loads should be confirmed by what means? site supervisor of controlling entity
According to ASME B30.5,when working a crane near power lines of 50kv or less, no part of the crane may come within what distance of the lines? ten feet
Blocking (cribbing) placed under outrigger beams: reduces the lifting base of the crane
Why use mats or cribbing? to reduce ground pressure
What must the operator do if there is reason to believe the lift may be dangerous or unsafe? refuse to lift the load until safety has been assured
Load chart ratings apply only when the ground conditions are firm enough to support and keep the crane: level throughout the lift
which is the proper way to get on and off the crane? face the machine when climbing on o off, using 3-point contact
If you set a crane up on a warm afternoon with the tires just touching the ground and overnight the temperature drops down below 30 degrees, what would be the position of the tires in the morning? be 2" above the ground
When entering a sit for he first time, what is the biggest concern? Compaction of access roadway
According to ANSI B30.5, a accessible fire extinguisher shall be available at all operator stations or cabs of equipment and shall have a minimum rating of what? 10 BC
When operating a crane near power lines of known voltage between 50kv and 200kv how much clearance is required? 15 feet
What is not a good location for crane setup? above utilities
In the event of electrical contact, the operator should do what? reverse action that caused contact
According to OSHA 1926. 1404; I assembly/disassembly is being performed by only one person, that person must meet the criteria for: Both competent person and qualified person
In the event of electrical contact in which the operator has to leave the crane how should he leave? Jump clear of the crane and hop away
Which of the following allows a part of the boom or the load to operate closer to power lines than the minimum required clearance? if transmission lines are de-energized and grounded
What is the minimum distance that must remain between any part of the crane and power lines when traveling under lines of know voltage over .75kv to 50kv? 6 feet
What is the OSHA regulation which governs cranes in general industry? 1910.180
Created by: 889920627731702
 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards