EPA

TermDefinition
type I technician person who maintain, service or repair small appliances
type II technican dispose of high or very high pressure appliances.
type III technican dispose of low pressure appliances.
universal technican repair both low & high pressure equipment & small appliances.
the compound gauge is blue & measures low pressure (psi) & vacuum (inches hg.)
the high pressure gauge is red & measures high side (discharge) pressure
the manifold is also eqpt. with center ports, (usually yellow hose) connected to a recovery device
epa regulations require the hoses be equpt with low loss fittings that will minimize refrigerant loss when hoses are disconnected.
a Ozone molecule consist of three oxygen atoms
Ozone protects us from harmful ultraviolet radiation & helps maintain stable temperatures
depletion of Ozone in the stratosphere causes crop loss, increase in eye diseases, skin cancer, reduce marine life, deforestation, increased ground level Ozone
CFC'S & HCFC'S deplete the Ozone layer
a single chlorine atom can destroy 100,000 Ozone molecules
chlorine in CFC's will neither dissolve in water nor break down into compounds that dissolve in water,so they don't rain out of the atmosphere
Ozone depletion potential is a measurement of CFC's & HCFC's ability to destroy ozone
HFC's (r-134a) don't contain chlorine & have no? ozone depletion potential
R-11, R-12,500 are? CFCs = chlorine fluorine carbon
R-22,123 are? hydrogen, chlorine fluorine carbon
R-134a is a? hydrogen fluorine carbon
after Nov. 14, 1994 certified required to purchase CFC & HCFC & small appl tech must be certified
after Nov. 15, 1993 refrigerant recovery & or recycling eqpt. must be certified & labeled by an EPA & you must evacuate to 10' prior to major maint. for 40 pd. system
since Nov. 15, 1995 violation to vent HFC's
since July 1, 1992 violation to vent CFC's or HCFC's
Dec. 31, 1995 CFC's were phased out of production
violation to dispose of a disposable cylinder with out first recovering any remaining refrigerant (to 0 psig) & then rending the cylinder useless. then recycling the metal
violation to fail to recover CFC's, HCFC's,or HFC before opening or disposing of an appliance
violation to fail to have an EPA approved recovery device, equipped with low loss fittings, & register the device with the EPA
violation to add nitrogen to a fully charged system, for the purpose of leak detection, and thereby cause a release of the mixture
to recover is to remove refrigerant in any condition from a system & store it in an external container
to recycle is to clean refrigerant for reuse by separating the oil from the refrigerant & removing moisture from the refrigeratn by passing it through one or more filter driers
to reclaim is to process refrigerant to a level equal to new (virgin) product spec as determined by chem analysis.
reclaimed refrigerants must meet the standard set forth in ARI 700 before it can be resold
system dependent captures refrigerant with the assist of component in the appliance from which refrigerant is being recovered
self contained has it's own means to draw the refrigerant out of the appliance
R-134a is a HFC & is considered ozone friendly, will not mix with most refrigerant oils,when leak testing an R-134a system to use pressurized nitrogen, R-134a refrigerant systems are ESTERS.
ternary which means a three part blend, are used with a synthetic alkylbenzene lubricant
most refrigerant oils are hygroscopic, have a high affinity for water.
temperature glide refers to a refrigerant blend that has a range of boiling points or condensing points through out the evaporator & condenser respectively
azeotropic blend mixture that acts like a single component refrigerant over it's entire temp/pressure range, doesn't have a temp glide
ti is important not to mix different refrigerant in the same recovery tank because the mixture may be impossible to reclaim. recover only one type of refrigerant into a recovery cylinder.
if a strong odor is detected during the recovery process what happen a compressor burn out has likely occurred, watch for signs of contamination in the oil
a suction line filter drier should be installed to trap any debris that may damage the new compressor
long hoses will cause pressure drop, and increase recovery time, & have a potential for increased emission
the lower the ambient temp the slower the recovery rate
use an electronic or ultrasonic leak detector to determine the general area on a leake
reason for dehydrating a refrigeration system is to remove water & water vapor,
if moisture is allowed to remain in an operating refrigeration system what will occur hydrochloric & hydrofluoric acids may form
never evacute a system to ambient air with out first following proper recovery procedures & attaining the mandated vacuum level
Recovery cylinders are designed to be refilled & have 2 ports, one liquid & one vapor
Recovery cylinders are not to be over filled above _______ or heat these cylinders may cause _______ 80%, An explosion
Refillable cylinder must be hydrostatically tested and date stamped every 5 yrs
Refillable cylinders used for transporting recovered pressurized refrigerant must be DOT approved
Approved refrigerant recovery colors are Yellow top & gray bodies
When pressurizing a system with nitrogen, you should always Charge thru a pressure regulator & insert a relief value in the downstream line from the pressure regulator.
Relief values must not be Installed in series, replaced if corrosion build up is found.
When leak checking a system never pressurize the system with Oxygen or compressed air, can cause an explosion.
To determine the safe pressure for leak testing,check The data plate for the low side test pressure value
Schrader values, it's critical to inspect for Core for leaks,bends & breakage, replace & always cap ports to prevent accidental depression.
Never heat a refrigerant cylinder with An open flame,don't cut or braze refrigerant line unit.
SCABA is required for Large release of refrigerant in a confined area, if SCBA isn't available, vacate & ventilate the area.
Inhaling refrigerant vapors or mist may cause Heart irregularities, unconsciousness, & oxygen deprivation leading to death (asphyxia)
Never expose R-22 or R-12 to open flames orrr glowing hot metal surfaces At high temperature, R-12 & R-22 decompose to form Hydrochloric acid,Hydrofluoric acid, & Phosgene gas.
Recovery eqpt. Manufactured Before Nov. 15, 1993 Must be capable of removing 80% of the refrigerant, whether or not compressor is operating, or achieve 4 inch vacuum under the conditions of ARI 740
Recovery eqpt. Manufactured after Nov. 15, 1993 Must be certified by an EPA testing laboratory as capable of recovering 90% of the refrigerant if the compressor is operating, 80% if it's not or achieve a 4 inch vaccum.
The only way to read refrigerant pressure accurately is A stable, known temperature.
Air in a refrigeration system will cause Higher discharge pressures
System dependent recovery process on an appliance with an operating compressor Run the compressor & recover from the high side of the system
System dependent recovery process on an appliance with an non-operating compress Access to both the low & high side of the system may be necessary.
System dependent recovery devices may only be used on appliances containing 15 lbs. Of refrigerant or less
Refrigerators built before 1950 may have used Methyl Formate , Methyl Chloride, or Sulfur Dioxide as refrigerant and should Not be recovered with current recovery devices.
Small appliances used in campers or other recreational vehicles may use refrigerants such as Ammonia, Hydrogen, or Water, and therefore should Not be recovered using current recovery eqpt.
When filling a graduated charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off the top of the cylinder Must be recovered.
After the installation of any type of system, The unit should first be pressurized with nitrogen & leak checked
In order to determine the general area of a leak use An electronic or ultrasonic leak detector. Once the general area of the leak is located the use of soap bubbles will pinpoint the leak.l
A refrigeration unit using open compressor that has not been used in several months is likely to Leak from the rotating shaft seal
EPA regulations require that all comfort cooling appliances more than 50lbs. Of refrigerant must be repaired when the annual leave rate exceeds 15%5
EPA regulations require that all Commercial & Industrial Refrigeration containing more than 50lbs. Of refrigerant Must be repaired when the annual leak rate exceeds 35%
Recovered refrigerants may contain acids, moisture, & oil Frequently check & change both the oil & filter on a recycling machine.
Before using a recovery unit you should always check the service value position, oil level of the recovery unit and Evacuate & recover any remaining refrigerant from the units receiver.
Technicians working with multiple refrigerants, before recovering & or recycling a different refrigerant, must purge the recover/recycle eqpt. by recovering as much of the first refrigerant as possible, change the filter, & evacuate. The only exception to this rule is for technicians working with R-134A who must provide a special set of hoses,gauges,vacuum pump, recovery or recovery/recycling machine, & oil containers to be used with R-134A only.
After recovery, refrigerant may be returned to the appliance from which it was removed or to another appliance owned by the same person without being recycled or reclaimed, unless the appliance is an MVAC like appliance. The technician should always evacuate an empty recovery cylinder before transferring refrigerant to the cylinder. Quick couplers, self-sealing hoses, or hand valves should be used to minimize refrigerant release when hoses are connected & disconnected.
System Dependant recovery eqpt. Can't be used on appliance containing more than 15lbs. Of refrigerant.
The most common refrigerant used in residential split air conditioning system was R-22, but now read the name plate to determine the type of refrigerant used.
Filter drier will remove moisture from the refrigerant in a system, But there is a limit to their caspacity. Some system are eqpt. with a moisture indicating sight glass. When the sight glass changes color, the system contains excessive moisture & will Need to be evacuated.The filter drier should be replaced anytime a system is open for servicing Strong odor detected, compressor burn out, watch for signs of contamination in the oil.
A crankcase heater is often used to prevent refrigerant from migrating to the oil during periods of low ambient temp. Refrigerant in the oil will cause oil foaming in the compressor at start up.
When evacuating a vapor compression system, the vacuum pump should be capable of pulling 500 microns (29.90''hg) of vacuum. The more accurate & preferred method of measuring a deep vacuum is in micron.
The use of a large vacuum pump could cause trapped water to freeze. During evacuation of system with large amounts of water, it may be necessary to increase pressure by introducing nitrogen to counteract freezing.
The source of most none condensable is air . None condensables will cause higher discharge pressures.
Where there is a risk of freezing, liquid charging of an R-12 refrigerant system should begin with vapor from a vacuum level to a pressure of approx. 33psig. Followed by a liquid charge thru. the liquid line service value
Ashrae standard 15 requires a refrigerant senor that will sound an alarm & automatically start a ventilation system in occupied equipment rooms where refrigerant from a leak will concentrate. Refrigerant CFC-12,CFC-11, & HFC-134a are categorized as A-1
All refrigeration system must be protected by a pressure relief valve (s). Must not be installed in series
Never energize a reciprocating compressor if the discharge service value is closed
Because a low pressure system operates below atmospheric pressure (in a vacuum), Leaks in the gaskets or fittings will cause air & moisture to enter the system.
The most effective method of leak checking a charged low pressure refrigerant unit is to pressurize the system by The use of controlled hot water or heater blankets or use nitrogen to increase pressure.
When pressurizing a system, don't exceed 10 psig Exceeding 10 psig can cause the rupture disc to fail.
When leak testing a water box Be certain the water had been removed before placing the leak detector probe thru the drain value.
To leak test a tube Use a hydrostatic tube test kid.
Systems with open drive compressors Are prone to leaks at the shaft seal.
Controlled hot water can be used to pressurize a system for the purpose of Opening the system for non major repairs
Under EPA regulations, a major repair means Any maintenance, service or repair involving the removal: compressor, condenser, evaporator or any auxiliary heat exchanger coil.
EPA regulations require that all comfort cooling appliances containing more than 50lbs. of refrigerant be repaired when The annual leak rate exceed 15%
EPA regulations require that all commercial & industrial process refrigeration containing more than 50lbs. of refrigerant be repaired when The annual leak rate exceeds 35%
A recovery unit's high pressure cut out is set for 10 psig when evacuating the refrigerant from a low pressure chiller and A rupture disc on a low pressure recovery vessel relieves at 15 psig.
Refrigerant recovery from a system using R-11 or R-123 starts with Liquid removal & is followed by vapor recovery.
A substantial amount of vapor will remain in the appliance after all liquid is removed. For instance, an average 350 ton R-11 chiller at 0 psig still contains 100 lbs of vapor after all the liquid has been removed.
When recovering refrigerant, the system water pumps and Recovery compressor, recovery condenser water should be all be on.
The ASHRAE guideline 3-1996 states that if the pressure in a system rises from 1 mm Hg to a level above 2.5 mm Hg during vacuum testing, The system should be leak checked.
A temp of 130°F should be attained when removing oil from a low pressure system Few refrigerants is contained in the oil at this higher temperature.
Recharging techniques Refrigerant is added thru the lowest access point on the system,the evaporator charging value.
Introducing liquid refrigerant into a deep vacuum will cause the refrigerant to boil and May lower temperatures enough to freeze water in the tubes,thereofore, initial charging is in the vapor phase.
Before charging with liquid an R-11 refrigerant system requires a vapor pressure of 26.9" Hg. vacuum, or A saturation temperature of 36°F.
Refrigerant Recovery & or recycling equipment manufacturered after November 15,1993 must be certified & labeled by an EPA approved equipment testing organization to meet EPA standards. All equipment must have low loss fitting to minimize refrigerant loss when hoses are disconnected.
Using recovery or recycling equipment manufactured or imported Before Nov.15,1993 25 inches Hg
Using recovery or recycling equipment manufactured or imported on or After Nov.15,1993 25 mm Hg absolute
Once the required vacuum has been achieved, the technician should wait for a few minutes & monitor the system pressure. If the pressure rises, indicating that there is refrigerant remaining in the system,recovery must be repeated.
When leaks in an appliance make evacuation to the prescribed level unattainable, the appliance should be Evacuated to the lowest attainable level prior to a major repair.
The use of large vacuum pump could cause trapped water to freeze. During evacuation of the system with large amount of water, it may be necessary to increase pressure by introduce nitrogen to counteract freezing.
If strong odor is detected during the recovery process, a compressor burn out may have occurred. When recovering refrigerant from a system that experience a compressor burn out ,watch for signs of contamination in the oil.
Because chillers using refrigerant such as CFC-11 & HCFC-123 operate below atmospheric pressure, they require a purge unit. The primary purpose of a purge unit is to remove none condensable from the system.
A centrifugal chiller's purge condensing unit takes its suction from the top of the condenser, removes air & other none condensable from the system, & returns refrigerant to the evaporator. Although a high efficiency purge unit discharges a low percentage of refrigerant with the air they remove, frequent purging & subsequent refrigerant loss can indicate that a leak is allowing air into the system.
High discharge pressure is also an indication of air in the system. Excessive moisture collection in the purge unit can indicate tube leakage.
To protect the system from over pressurization, low pressure chillers typically use a rupture disc mounted on the evaporator housing. The typical design burst pressure for a rupture disc is 15 pisg.
ASHRAE standard 15 requires a refrigerant monitor that will sound an alarm & automatically start a ventilation system in equipment rooms before the refrigerant concentration reaches the threshold limit value time weighted average. A refrigerant monitor is required for all ASHRAE refrigerant safety groups.
CFC-12, CFC-11, & HCFC-134 are coded grouped as A-1 R-123 is coded grouped as B-1
All refrigeration system must be protected by a pressure relief valve (s) Must not be installed in series.
Created by: Rafael Leon
 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards