Save
Upgrade to remove ads
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

RT 20 Digital

physics digital test

QuestionAnswer
_____is the ability to image two separate objects visually detect one from the other resolution
the science of______ is the study of the response of the human eye to light photometry
radiographic_____ is the random fluctuation of the optical density of the radiograph Noise
in Digital radiography, the latent image is formed on the radiation detector
switching from screen film imaging to computer radiography can____ patient dose reduce
what is the basic photometric unit lumen
spatial resolution improves with decreased _____blur geometric, screen, and motion
in digital radiograghy the brightness of the image is determined by pixel values
computed radiograghy screens respond to radiation with photostimuable luminescence
scanned projected radiography was developed as a complement to computerized tomography
preprocessing the digital image is done automatically
postprocessing the digital image is done manually
the slope of the ____ portion of the charactaristic curve shows the film contrast straight line
computed radiograghy imaging produces____ gray levels 10,000
in digital radiography, spatial resolution is improved with increased______ matrix size
during preprocessing, the digital output of the image receptor may need to be manipulated to correct dead pixels
an image receptor with _____ can be used over a greater range of exposeures wide latitude
the computed radiographt cassette is called an imaging plate
computed radiography uses_____ for latent image formation photostimulable phosphor
is done during preprocessing to correct for an irregular pattern of the image flatfielding
the primary geometric factors affecting image quality are magnification, distortion, and focal spot blur
the photostimuable phosphor screen is handled in a reader
conventional x ray tubes and cassettes are used with_____ radiography systems computed
what is the formula for the magnification factor MF=SID/SOD
backscatter radiation artifacts can occur more readily in digital imaging because of the highly sensitive receptors
four steps of creating an image with computed rediography are metastable state, stimulate, read, and erase
in digital, each matrix pixel represents atomic number and mass density
the best way to minimize magnification is to use long SID and small OID
europium is the_____ of the photostimuable phosphor activator
a graph of the frequency of occurances versus digital value intervals is called______ histogram
spatial frequency is used to describe the quality of spatial resolution in terms of line pairs
focal spot blur can be reduced by usin a smaller focal spot
t/f....the digital imaging plate can sit for sometime after the erase cycle false
in digital imaging, spatial resolution is ultimately limited by pixel size
subject contrast is affected by patient thickness
each anatomical part has an image histogram with____shape characteristic
the human visual system can distinguish______shades of gray 30
histogram selection is done____ by the radiographer before each exam
computed radiography and screen film imaging both have an____ latent image
the number of gray shades that an imaging system can reproduce is called its dynamic range
between the abdomen, chest, skull, and pelvis, which part has the highest subject contrast chest
the principal source of noise in computed radiography is scatter radiation
the_______ digital imaging system uses the highet dynamic range mammography
radiographic image quality is improved when the______is increased source image distance
creating distinctly collimated margins on all 4 sides of the DR image is important in preventing_______ errors histogram analysis
image detail is also called spatial resolution
patient thickness affects image quality by affecting_______ magnification, focal spot blur, and radiographic contrast
the computed radiograghy image has wide exposure latitude and improved contrast resolution.
with digital imaging patient dose can be reduced by using higher_____technique kVp
the technologist primarily controls radiogrphic contrast by varying the Kilovoltage
a ghost image can occur in digital imaging because of an image is not fully erased
the software correction that equalizes the response of each pixel to uniform exposure is flatfielding
DQE is an acronym for Dective Quantum Exposure
Improves as screen blur decreases, motion blur decreases, and geometric blur decreases Spatial resolution
the use of high mass, low kvp, and slower image receptors reduces quantum mottle
latitude and contrast are_______ proportional inversly
unequal maginification of different portions of the same object is callled Distortion
the most important factor for determining spatial resolution focal spot size
3 thing to reduce motion blur Decrease Exposure time, give instructions, use immobilizers
In the CR reader the latent image is made visible bt realeasing the_____________with stimulating laser light beam metastable electrons
spatial resolution in DR is pixel limited
IP Imaging plate
PD photodiode
PMT Photomultiplier tube
PSL photostimuable luminescence
PSP Photostimulable phosphor
SP storage phosphor
SPS Storage phosphor screen.
as matrix size increases the pixel size_____ and the resolution______ decreases, increases.
_____are the light detectors of choice for CR photodiodes
the first of the sequence of events that result in an xray induced image forming signal Expose
results from the interaction of an infrared laser beam with photostimulable phosper stimulate
the light signal emitted after stimulation is detected and measured Read
before reuse, an residual electrons are moved to ground state by an intense light Erase
Created by: 1820547421
 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards