X-ray Circuits Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Question | Answer |
line voltage compensator is incorporated into the primary circuit to: | maintain a constant kVp level |
this meter measures the current passing between the electrodes of an x-ray tube | millammeter-seconds meter |
the voltage in the secondary circuit of a modern x-ray cicuit is how many times greater than in the primary circuit? | 1000 times higher |
the high temps that are needed to produce the thermionic emission in the filament of an x-ray tube require a current of about: | 4-6 amps (temp of 2200 degrees celcius) |
why are the majority of the components of the x-ray tube found in the primary circuit? | reduce the risk from electrical shock |
type of current passing between the seconday of the high-tension transformer and the rectifiers | High voltage (kV) AC |
large focal spot is used for settings above what mA? | 300 mA |
higher mA= _______ current, _________ temp of the filament | higher, higher |
the high tension transformer is located in an oil-filled tank that also houses the | rectifiers and filament transformers |
an increase in kVp will also cause an increase in _____________ that requires the use of a _________________. | electron cloud, space charge compensator |
this meter measures current | ammeter |
main component of a line-voltage compensator that is capable of storing small amounts of electrical charge | capacitor |
the pre-reading kV meter is incorporated into the x-ray control panel to measure the potential difference on the | seconary side of the high tension transformer |
most common device used to create the high potential difference across the x-ray tube | high tension transformer |
reduction of voltage and development of high amperage by a step down transformer occurs in the | filament portion of the circuit |
in a radiographic unit, the milliammeter will register only during the activation of the | second (exposure) stage of the exposure switch |
which circuit? 110, 220, 440 volts | primary circuit |
which circuit? 10-12 volts | filament circuit |
which circuit? 25,000-150,000 volts | secondary circuit |
five main components of the high tension or high voltage circuit | transformer, the millampere-seconds (mAs) meter, the rectifiers, the high tension cables and the anode of the x-ray tube |
why can you only obtain mAs meter readings immediately after an exposure? | tube current is only generated during the second phase of the x-ray production process |
power | watts |
power formula | current X voltage= watts |
a transformer has 200 primary and 20,000 secondary turns of wire. what secondary voltage will be induced if 110 volts are placed on the primary coil? | 11,000 (11 kVp) |