Oil Furnace Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| What are three products of combustion? | 1) Heat 2)Water Vapor 3) Co2 |
| Two types of oil burners pumps | single and dual stage |
| Three functions of the oil burner nozzle | 1) Atomizing 2) Metering 3) patterning |
| 3 storage tank design | indoor, outdoor, and underground |
| which is storage tank design? | indoor, easy access to test. |
| how do you test water fuel tank? | wax on the stick |
| Bypass plug product remove | one stage |
| Fuel line not required | PVC or cast iron fittings |
| Process of fuel combustion | atomization |
| one pound fuel oil | 3 |
| One gallon fuel produce how many btu | 140,000 btu |
| How much excess air? | 50% |
| Fuel oil pump rotary pump? | false, gear driven design. |
| First stage | pull from tank for long distance. |
| Second Stage | push to nozzle into burner |
| List six of the main components of a fuel oil burner | 1)End Cone 2) Air tube 3) fuel pump 4) Blowing housing 5) Blower wheel 6) Nozzle |
| how does end cone on retention burner better combustion ? | Squirrel, increase volume |
| Three type of combustion heat, water, and vapor | False |
| Most burner motors are | PSC |
| burner motor connect to fuel pump | flexible coupling |
| The burner fan is | squirrel cage |
| Three functions of nozzle | 1) atomize 2) metering 3)patterning |
| Two information stamp of nozzle | 1) orifice size 2) spray angle |
| Why spray pattern is important? | Design of the burner box |
| Spray angle | 30 to 90 degree |
| Nozzle can be use as file by metal brush. | false, replace it. |
| Name the three spray patterns | 1) Hollow 2) semi-Hollow 3) solid |
| Which type spray burner use larger burner? | Solid |
| Air blowing combustion chamber burner through | Air tube |
| Metal rode insulate ceramic insulate would identify | electrode |
| What determine the shape combustion chamber? | Nozzle spray angle |
| Four Primary control functions: | 1) Safety function 2) shutdown burner 3) ignition process 4) Start and stop blow motor |
| What are two types of primary control? | 1) Stack switch 2) cad cell switch |
| Primary control that use hot and cold contact | stack switch |
| Cad cell be able shutdown burner if flame is not present | False |
| The typical resistant cad cell sense light | 600 to 1000 ohms |
| STI-P3 stands for | Steel Tank Institute-Protected 3 ways |
| What are four characteristics of forced-air furnace? | 1) low-boy 2)upflow 3)downflow 4)horizontal |
| Fuel oil compose of | 1) hydrogen 2) carbon |
| If the oil tank is located above the oil burner | One-pipe system |
| Oil storage tank is located below the oil burner | Two-pipe system |
| Oil lines should be: | 3/8" OD copper lines, made of copper, steel, or brass. Never use PVC nor Cast-iron, flare connection |
| Oil deaerator | Oil pipe component that allows a one-pipe system to function as a two-pipe system |
| Ash content definition: | The amount of combustible materials contained in the fuel oil |
| Distillation quality definition: | The ability of the oil to be vaporized. |
| Pour Point definition: | The lowest temperature at which the fuel can be stored |
| Carbon Residue definition: | The amount of carbon left in a sample of oil after it is changed from a liquid to a vapor by being boiled in an oxygen-free |
| Viscosity definition: | The thickness of the oil under normal temperature |
| Ignition Point definition: | A few degree higher than the flash point |
| Flash Point definition: | The lowest temperature at which vapors in the air above the fuel oil ignite for a short period of time when exposed to flame |