2nd Class C Boiler Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| The most important valve on a boiler is the_____ Valve. | Safety Valve |
| The funtion of a flame device is to shut off the _____. | fuel supply when the burner flame goes out |
| When used, a quick-opening blowdown valve be located_______. | Nearest to the boiler |
| The low-water cotoff (LWCO) is a divice fitted to the boiler to shut off the_____. | fuel supply to the burners when water level in the boiler is low |
| Try cocks on a water calumn are used to_____. | check the water level in the boiler |
| A check valve is a valve that_____. | allows flow in one direction only |
| Black smoke can be caused by_____. | isufficient combustion air |
| Large high pressure utility boiler use_______ | Natural Draft |
| Handhole and manhole opening_____. | Are used for draining the boiler |
| The maximum pressure allowed in a low pressure hot water boiler is no more than _____psig. | 160 |
| In accordance with the statutes of the State of Minnesota , one Boiler horspawer for conventional boiler is equal to______. | 10 sq ft of boiler heating surface |
| A botton blowdown system can be equipped with slow-opening and quick-opening valves, with the quick-opening valve located_____. | cosest to the boiler opened first |
| A hydrostactic test test is considered to be a____ test that is used to determine if the component works as designed. | proof |
| Modulating combustion controls_____. | regulate the steam and feedwater supply |
| Boiler water with a PH of 6 is considered_____. | Acid |
| When the boiler heating surface cannot be discerned, the boiler horsepower shall be determinated by dividing the Btu imput by__________. | 67,000 |
| The feedwater line cotain_____. | check valve between a stop valve and a boiler |
| A Special Engineer is expected to be competent, take charge of, and be resposible for the safe operation and maintenance of all classes of boiler of not more than_______HP and their appurtenances. | 50 |
| The purpose of a steam trap is to_____. | Remove air and condensate from stean line |
| For the porpuse of the boiler and pressure vessel statutes, "a year" is considered to be a least_______hr. | 2000 |
| Convection is a method of heat transfer where the movement of fluids is due solely to the_______. | Flow of fluids |
| The float chamber of the low water fuel cutoff (LWCO) is frequently blown down to prevent the_____. | float chamber from collecting sediment |
| A cross tee fitting is used on boiler column connections to_____. | Install vent valves |
| A logbook must be maintained in the boiler room by the_______. | A chief engineer of operating engineer designee |
| The boiler heating surface_____. | Is a smaller in watertube boiler than in the firetube |
| _____Valve should be used if a valve is required in a steam line from throttling action. | globe |
| Combustion is_____. | chemical combination of the elements of fuel with oxygen |
| With regard to steam boiler, the letters "HRT"mean_____ | Horizontal return tubular |
| _____ is the flow of air or gases of comustion caused by a difference in pressure between two points. | draft |
| The shief engineer of a high pressure boiler plant of over 200 HP must stay within______of the boiler room at all times during the shief. | 500 ft |
| The boiling point of water within a pressurized boiler will_____. | 212 0f |
| When heat is tranferred by the flow of fluids, it is know as_____. | Convection |
| In accordance with the statutes of the State of Minnesota, each electric boiler horsepower is equal to________Kilowatts. | 10 |
| The main purpose of installing insulation on steam system piping is to_____. | Prevent heat loss |
| The material used most frequently for piping is____. | stainless steel |
| In a boiler, heat is transferred from the burning fuel to the water by________. | convection, conduction, radiation |
| Foaming in a boiler may be caused by_____. | A high concetration of dissolved solids in the boiler water |
| In a natural draft furnance, the amount of draft is affected by the____. | size of the induced draft fan |
| The main funtion of a gas burner is to_____. | mix the gas with combustion air |
| Before filling a boiler with water, the licensed engenieer should ensure that_____. | the flame scanner has been tested |
| Licenses granted must be displayed in _____________. | A conspicuous place in the engine or boiler room |
| The best method of testing a low-water fuel cutoff (LWCO) is to______. | Blow down the float chamber to determine in the burner will cut out |
| A test connection between the siphon tube and the boiler pressure gauge is need to _____. | test steam temperture at the pressure shown on the gauge |
| A steam boiler operating control is used to control the_____. | setpoint on the safety valve |
| A way to determine is safety vlave on a boiler has sufficient capacity is to_______ | check with the ASME Code |
| The safety valve test must not be used unless_____ | another licensed engineer is present |
| In accordance with the ststutes of State of Minnesota, one boiler horsepower for steam-coil-type generators is equal to ______. | 5 sq ft of boiler heating surface |
| As steam pressure increases, there is a correponding increase in the _____. | Boiling temperature of the water in the boiler |
| A hydrostatic test is a mandatory requirement when a new boiler is intalled in the State of minnesot. The test pressure requirement must no exceed_____time the maximum allowable working pressure. | 1.5 |
| Heat that brings about a change of sate without causing a change in temperature is_______. | called latent heat |
| The two general desings of electric boiler are the_____types. | Electrode and Resistance |
| When heat transfer occurs by travelling through metal, it is known as _________. | radiation |
| A low-water cutoof (LWCO) prevents boiler damage by_____. | cutting off the fuel supply to prevent overheating of any part of the furnance |
| _____ is any solid impurity in water that cannot be dissolved. | Suspended matter |
| The minnimun passing score for a Minnesota engineer's license examination si______%. | 70 |
| Boiler baffles are used_____. | to direct the flue gases through the boiler furnance |
| When hot combustion gases travel through boiler tubes that are surrounded by boiler water, the boiler is called a _____ Boiler. | Firetube |
| A low-water fuel cutoff (LWCO) is used on a boiler to prevent_____. | Damage due to burner overfiring |
| A gauge glass can be attached to a______Column, wich is attached to a boiler. | water |
| A watertube boiler is a boiler that has_____. | Water on the outside of the tubes and hot gas on the inside of the tubes |
| A_____blowdown is performed to remove sludge from a boiler | botton |
| Rules goerning the construction of power boiler are set out in_____. | ASME Code Section I |
| A high pressure boiler must two means of feetwater supply if it exceeds_______HP. | 500 |
| In a deaerator, dissolved gases are removed from the water by_____. | forncing the water through organic screens and venting the gases to the atmosphere |
| A siphon tube is necessary to_____. | prevent water from entering a steam gauge |
| The correct procedure for blowing down a high pressure boiler is to open_____. | the quick-opening valve first and close it last |
| The document governing boiler fitting and valves is the____code | ASME |
| Sensible heat is_________. | Able to cause a change in temperature |
| Internal water treatment_____. | Consists of chemicals added to the boiler feedwater |
| Expantision bends or joins are installed in piping systems to____. | allow for expansion and contraction of piping without causing damage |
| Continuos blowdown systems are udes in boiler_____. | To help control the dissolved solids concentration |
| The evaporative capacity of a steam boiler is stated as pound of steam per_____. | Hour |
Created by: